Ohio Medical Gas Fittings And Adapters
53Pages

{{requestButtons}}

Catalog excerpts

Ohio Medical Gas Fittings And Adapters - 1

respiratory • anesthesia • surgical • dental • ER/EMS • clinical engineering • home care

Open the catalog to page 1
Ohio Medical Gas Fittings And Adapters - 2

Critical Communication 1111 Lakeside Drive ♦ Gurnee, IL 60031-4099 ♦ 847-855-0500 ♦ NASF Critical Communication 022707 February 27, 2007 Addendum to Fittings and Adapters Catalog Dear Selling Team, Please note the following corrections to the Fittings & Adapters Catalog. Page 5 – Body Adaptor, 1/4” NPT Male: Part number 6700-1411-804 should be 6700-1411-805 Page 6 – Nipple, 1/8” NPT Male: Part number 6700-1810-801 should be 6700-1810804 Page 8 – Components: Part number 6700-1401-500 should be 6700-0169-500 Page 10 – Two –Piece Swivel Outlet, Disposable (l) o 6700-1921-800 should be...

Open the catalog to page 2
Ohio Medical Gas Fittings And Adapters - 3

Color-coding Explanation Color-coding is used as a gas identifier worldwide for medical gas fittings and connections. The following color-coding chart shows the USA color-coding standards on the left and the ISO color-coding standards on the right. Carbon Dioxide Grey Grey He-02 Brown and Green Brown and White Medical Air Yellow Black and White Nitrogen ^ p Black ^ p Black Nitrous Oxide m ) Blue ( \ Blue 02~He Green and Brown White and Brown Oxygen Green White Vacuum (Suction) white Yellow WAGD(EVAC) (^) Purple Purple for ordering information, please call 1.866.549.6446

Open the catalog to page 3
Ohio Medical Gas Fittings And Adapters - 4

for ordering information, please call 1.866.54

Open the catalog to page 4
Ohio Medical Gas Fittings And Adapters - 5

DISS Nuts Diameter Index Safety System DISS explanation on page 50 Note: (I) Heliox mixtures: Helium over 80%. (II) Heliox mixtures: Helium not over 80%. (III) Intended for the powering of medical devices unrelated to human respiration. (IV) Provides a leak-tight seal rated at 200 psi gas service. for ordering information, please call 1.866.549.6446

Open the catalog to page 5
Ohio Medical Gas Fittings And Adapters - 6

DISS Body Adaptors 200 psi max • Gas service stamped on body adaptors Diameter Index Safety System DISS explanation on page 50 Note: (I) Heliox mixtures: Helium over 80%. (II) Heliox mixtures: Helium not over 80%. (III) Intended for the powering of medical devices unrelated to human respiration. F or DISS Body Adaptors with Demand Check Units and One-Way Check Valves, see pages 14 and 15. for ordering information, please call 1.866.549.6446

Open the catalog to page 6
Ohio Medical Gas Fittings And Adapters - 7

DISS Nipples Diameter Index Safety System DISS explanation on page 50 Nut Hex Nut - for use with DISS Nipples Note: (I) Heliox mixtures: Helium over 80%. (II) Heliox mixtures: Helium not over 80%. (III) Intended for the powering of medical devices unrelated to human respiration. for ordering information, please call 1.866.549.6446

Open the catalog to page 7
Ohio Medical Gas Fittings And Adapters - 8

DISS Nipples with O-rings Diameter Index Safety System Hex Nut - for use with DISS Nipples with O-rings DISS explanation on page 50 Hand-tight Nut for use with DISS Nipples with O-rings Note: (I) Heliox mixtures: Helium over 80%. (II) Heliox mixtures: Helium not over 80%. (III) Intended for the powering of medical devices unrelated to human respiration. for ordering information, please call 1.866.549.6446

Open the catalog to page 8
Ohio Medical Gas Fittings And Adapters - 9

DISS 1240 Oxygen Nuts, Nipples and Components Diameter Index Safety System DISS explanation on page 50 Nut Note: (I) Not intended for static pressure build-up. Nipple, Hose Barb Nipple, Hose Barb with O-ring Nipple, Tapered Barb (I) Nipple, 1/8" NPT Male with O-ring for ordering information, please call 1.866.549.6446

Open the catalog to page 9
Ohio Medical Gas Fittings And Adapters - 10

DISS 1240 Oxygen Body Adaptors Diameter Index Safety System DISS explanation on page 50 Demand Check Units and One-Way Check Valves, see pages 14 and 15 for ordering information, please call 1.866.549.6446

Open the catalog to page 10
Ohio Medical Gas Fittings And Adapters - 11

DISS 1240 Oxygen Adaptors and Connections Diameter Index Safety System DISS explanation on page 50 Note: (I) Not intended for static pressure build-up. (II) Provides a leak-tight seal rated at 200 psi gas service. Male Coupler Female Coupler for ordering information, please call 1.866.549.6446

Open the catalog to page 11
Ohio Medical Gas Fittings And Adapters - 12

DISS 1240 Oxygen Female Adaptors Diameter Index Safety System DISS explanation on page 50 for ordering information, please call 1.866.549

Open the catalog to page 12
Ohio Medical Gas Fittings And Adapters - 13

DISS Hex Nut & Nipple Combinations 200 psi max Includes O-rings (unless otherwise noted) Diameter Index Safety System DISS explanation on page 50 Note: (I) Heliox mixtures: Helium over 80%. (II) Heliox mixtures: Helium not over 80%. (III) Intended for the powering of medical devices unrelated to human respiration. for ordering information, please call 1.866.549.6446

Open the catalog to page 13
Ohio Medical Gas Fittings And Adapters - 14

DISS Hand-tight Nut & Nipple Combinations Diameter Index Safety System DISS explanation on page 50 for ordering information, please call 1.866.549.6446

Open the catalog to page 14
Ohio Medical Gas Fittings And Adapters - 15

Demand Check Units Diameter Index Safety System Typical Operation DISS explanation on page 50 No Flow Mechanism automatically shuts off gas supply when disconnected Unit opens when mating connection is complete for ordering information, please call 1.866.549.6446

Open the catalog to page 15
Ohio Medical Gas Fittings And Adapters - 16

One-Way Check Valves Diameter Index Safety System Typical Operation DISS explanation on page 50 Direction of Flow Gas Pressure Activated Note: (I) An extension adaptor is necessary when full-free extension of poppet is not obtained. for ordering information, please call 1.866.549.6446

Open the catalog to page 16
Ohio Medical Gas Fittings And Adapters - 17

Power Take-off Assemblies Note: Special configurations are available upon request. for ordering information, please call 1.866

Open the catalog to page 17
Ohio Medical Gas Fittings And Adapters - 18

Dual Outlet Y-Connections for ordering information, please call 1.866.549.6446

Open the catalog to page 18
Ohio Medical Gas Fittings And Adapters - 19

100 psi max • Short projection designs which reduce stress on wall outlet connections. Note: Special configurations are available upon request. See pages 20-21 for further information regarding Chemetron® style quick-connects. for ordering information, please call 1.866.549.644

Open the catalog to page 19
Ohio Medical Gas Fittings And Adapters - 20

100 psi max • Short projection designs which reduce stress on wall outlet connections. Note: Special configurations are available upon request. See pages 22-23 for further information regarding Ohmeda® style quick-connects. for ordering information, please call 1.866.549.6446

Open the catalog to page 20
Ohio Medical Gas Fittings And Adapters - 21

Chemetron ® Style Male Quick-Connects DISS Male DISS Female Hex Nut & Nipple Hose Barb DISS Demand Check Unit for ordering information, please call 1.866.549.6446

Open the catalog to page 21
Ohio Medical Gas Fittings And Adapters - 22

Chemetron ® Style Female Couplers 1/8" NPT Male DISS Male DISS Female Hex Nut & Nipple Hose Barb for ordering information, please call 1.866.549.6446

Open the catalog to page 22

All Ohio Medical catalogs and technical brochures

  1. Medical Device

    56 Pages

  2. Cuff Sentry

    2 Pages

  3. Amvex Catalog

    28 Pages

Archived catalogs

  1. Care-E-Vac 3

    4 Pages