Aurora 1030W TOC Validation Package

Aurora 1030W TOC Validation Package

Product catalog summary
Overview
The Aurora 1030W Validation Package is designed for validating the 1030W TOC (Total Organic Carbon) instrument, ensuring compliance with GLP (Good Laboratory Practice) and GMP (Good Manufacturing Practice) standards in pharmaceutical and biotechnology applications. The package supports high sensitivity measurements necessary for Cleaning Validation (CV), Purified Water (PW), and Water for Injection (WFI) applications.

Specifications
The Aurora 1030W TOC Analyzers utilize heated persulfate wet oxidation for precise measurements. The validation package includes 21 CFR Part II compliant software to meet operational requirements in GLP and GMP environments.

Deliverables & Support
The package provides comprehensive validation protocols for installation qualifications (IQ), operation qualifications (OQ), and performance qualifications (PQ). It includes certification documents to record successful completion of each validation step. An OI Analytical technician can perform on-site installation and validations, ensuring the instrument's compliance with manufacturer specifications, including accuracy and reproducibility.

Principal Application
The validation package is primarily used for:
  • Cleaning Validation (CV)
  • Purified Water (PW)
  • Water for Injection (WFI)

Protocols & Documentation
The package includes:
  • Installation Qualifications (IQ)
  • Operation Qualifications (OQ)
  • Performance Qualifications (PQ)
  • Standard Operating Procedures (SOPs)
  • Certification Documentation

Contact Information
OI Analytical
PO Box 9010, College Station, TX
Phone: (979) 690-1711
Fax: (979) 690-0440
Website: www.oico.com
Email: [email protected]

Conclusion
The Aurora 1030W Validation Package ensures the instrument is properly installed and validated, supporting ongoing compliance with GLP/GMP standards throughout its operational life.
See more

Catalog excerpts

Aurora 1030W TOC Validation Package-1

PHARMACEUTICAL Aurora 1030W TOC Validation Package Complete IQ, OQ, PQ Documentation with On-Site Support Deliverables & Support The Aurora 1030W Validation Package provides complete documentation for validating a 1030W TOC (Total Organic Carbon) instrument for use in pharmaceutical and biotechnology GLP/GMP applications. The Aurora 1030W Validation Package consists of instrument validation protocols for installation qualications (IQ), operation qualications (OQ), and performance qualications (PQ) and matching certication documents to record successful completion of each step with a signature and date. Aurora 1030W TOC Analyzers employ heated persulfate wet oxidation to perform the high sensitivity measurements required in Cleaning Validation (CV), Puried Water (PW), and Water for Injection (WFI) applications. The 21 CFR Part II compliant software and Aurora 1030W validation package ensure the instrument meets all requirements for operation in GLP and GMP environments. Installation Validation Package Installation Qualications Operation Qualications Performance Qualications Standard Operating Procedures OI Analytical PO Box 9010 College Station, TX An OI Analytical technician is available to install the Aurora 1030W TOC analyzer and perform the IQ, OQ, PQ validations, providing certications to be maintained with instrument records for inspections or audits. Organizations that use in-house personnel to conduct instrument validations may obtain the validation package separately. The validation package and on-site installation ensure the Aurora 1030W is properly installed, verify operation of all critical sub-components using NIST-certied meters, and conrm system performance to manufacturer specications, including accuracy and reproducibility, using a test standard supplied by OI Analytical. The validation documents support the initial validation of an Aurora 1030W instrument and continuing validations over the lifetime of the instrument. Principal Application Protocols & Documentation Validation of Aurora 1030W TOC Analyzers for GLP/GMP compliance supporting: • Cleaning Validation (CV) • Puried Water (PW) • Water for Injection (WFI) • Operation Qualications (OQ) • Performance Qualications (PQ) • Standard Operating Procedures (SOPs) • Certication Documentation PO Box 9010 College Station, Texas 77842 Tel (800) 653-1711 • Fax (979) 690-0440 www.oico.com • E-mail [email protected]