Model 1088 Rotary Autosampler Specification Sheet
2Pages

{{requestButtons}}

Catalog excerpts

Model 1088 Rotary Autosampler Specification Sheet - 1

1088 Rotary Autosampler Autosampler for the Aurora 1030 TOC Analyzer • Automates introduction of 88 samples to the Aurora 1030 TOC Analyzer • Congurable for pre-acidication and sparging of sample TIC content within the autosampler to reduce TOC analysis time • Performs programmable rinse steps via an integral wash station to clean the sampling needle and prevent crosscontamination • Magnetic stirring ensures insoluble and particulated samples are homogeneous for accurate results • Fits directly under the Aurora 1030 TOC analyzer to minimize laboratory benchspace requirements • Supports sampling from open vials and septum piercing of sealed vials Description and Function Principal Applications • Drinking water • Wastewater • Ultrapure water • Cleaning validation • Water for injection • Groundwater • Surface water • Industrial process water • Seawater Sampling Methods • Open vial • Septum piercing The 1088 Rotary Autosampler is specically designed to operate with an Aurora 1030 TOC analyzer. The 1088 autosampler aspirates liquid samples from vials and transfers each sample aliquot to an Aurora 1030 TOC analyzer for analysis. A removable 88-position autosampler tray loads the sample vials for fully automated, unattended operation. The 1088 supports a number of special functions to address a range of sample conditions and analysis requirements. Onboard magnetic stirring ensures samples containing insoluble components or particles are homogeneous for sampling and accurate analysis. Septum piercing provides closed vial sampling for applications where open vials may comprise the accuracy of measurements. System conguration for sample pretreatment allows pre-acidication and purging of samples within the 1088 prior to sampling. This technique removes the TIC content of samples, reducing the analysis time required for TOC measurements. Operating Principle The sampling sequence of the 1088 autosampler is user-programmed through the Aurora 1030 touchscreen display. A stepper motor drive positions the appropriate vial below the sampling needle. The needle mechanism then lowers into the vial, aspirates the specied sample volume, and transfers it to the reaction chamber of Aurora 1030. Following sample transfer, the sampling needle returns to a wash station to be rinsed. A user-programmable number of rinses are then performed to clean the needle before the next vial is sampled.

Open the catalog to page 1
Model 1088 Rotary Autosampler Specification Sheet - 2

Specications 64.77–cm H x 38.1–cm W x 48.26–cm D (25.5” H x 15” W x 19” D) Weight (1088 Autosampler) 19 kg (42 lbs) Dimensions 66–cm H x 47–cm W x 66–cm D (1088 Autosampler & Aurora 1030) (26” H x 18.5” W x 26” D) Weight (1088 Autosampler & Aurora 1030) 34.4 kg (76 lbs) Benchspace Footprint 3,102 cm2 (494 in2) Environment 15–35 °C operating temperature 10–90% relative humidity Sample Capacity 88 sample vials Sampling Needle 8.4”, two-hole, stainless steel ® Sample Transfer Tubing 0.045” I.D. x 1/8” O.D. Teon tubing Vials 40-mL VOA vials Caps Open-hole caps Septa TFE-faced septa Sample...

Open the catalog to page 2

All OI Analytical catalogs and technical brochures

  1. Eclipse 4760

    4 Pages

  2. 4450 PID/FID

    2 Pages

  3. CHROM-LINK®

    2 Pages

  4. Eclipse 4760

    4 Pages

  5. 5383 PFPD

    2 Pages

  6. 4430 PID

    2 Pages

  7. 5320 ELCD

    2 Pages

Archived catalogs