Overview: The OKM 800 Multi-Parameter Monitor is designed for use in intensive care and anesthesia settings, suitable for adult, pediatric, and neonatal patients. It features a 12.1” color TFT touch screen and supports waveform monitoring up to 9 channels.
Performance Specifications: The monitor includes an electronic keyboard, interchangeable waveform colors, and a drug dose calculation program for 15 drugs. It supports 3, 7, or 12 lead ECG measurements, extended arrhythmia, and ST segment analysis. It is compatible with pacemakers and includes a defibrillator synchronization socket.
Safety and Standards: The monitor is FDA and ISO 13485:2003 approved, with CE marking according to MDD93/42/EEC. It offers IPx1 protection against water ingress.
Electrical Characteristics: Operates on a power supply of 100-240V, 50/60Hz, and includes a rechargeable lithium-ion battery with a capacity of 2200mAh, providing up to 4 hours of backup.
Environmental and Physical Characteristics: Operates within a temperature range of 5-40°C and humidity up to 93%. It weighs 3.9kg and measures 346.1mm x 301.5mm x 178.5mm.
Interface and Connectivity: Includes parameter cable interfaces, AC power input, software upgrade ports, RJ45, and nurse call ports. Supports both wired and wireless connections to a central monitoring system.
Alarm and Indicators: Features auditory and visual alarms with user-adjustable limits, and indicators for power, battery, and alarms.
ECG Specifications: Supports 3, 5, and 12-lead ECG configurations with a heart rate range of 15-350 bpm, offering high accuracy and protection against interference.
Respiration and SpO2: Respiration is measured via thoracic impedance, with a range of 0-150 rpm. SpO2 measurement ranges from 0-100% with high accuracy.
EtCO2 and Temperature Monitoring: Uses non-dispersive infrared technology for EtCO2 measurement, with a range of 0-150 mmHg. Temperature is measured with dual channels, offering a range of 0-50°C.
NIBP Monitoring: Uses an automatic oscillometric method for blood pressure measurement, with adjustable auto measure times and comprehensive pressure range settings for different patient types.
Blood Pressure Monitoring: Supports Adult, Pediatric, and Neonate modes with respective pressure ranges of 20-235 mmHg, 20-165 mmHg, and 20-110 mmHg. Features both hardware and software over-pressure protection, with an accuracy of less than ±5 mmHg and a resolution of 1 mmHg. Alarms are available for systolic, diastolic, and mean pressures.
Pulse Oximetry (SpO2): Displays pulse oximeter values, SpO2 bar graph, and volume recorded waveform. The measurement range is 1-100% with an accuracy of ±2% for pediatric and ±3% for neonate in non-motion conditions. The pulse rate (PR) measurement range is 20-300 bpm with an accuracy of ±3 bpm in non-motion and ±5 bpm in motion.
EtCO2 Monitoring: Uses Masimo technology for sidestream and mainstream CO2 measurement with a range of 0-190 mmHg. Accuracy varies with the range, and the response time is less than 3 seconds for sidestream and less than 1 second for mainstream. The respiratory rate range is 0-150 rpm with an accuracy of ±1 rpm.
Bispectral Index (BIS): Measures BIS, SQI, EMG, SR, BC, and TP with a range of 0-100. The EEG sampling frequency is 2048 Hz with a CMRR greater than 150 dB. Event marking and various sweep speeds are supported.
Gas Measurement: Supports measurement of CO2, N2O, Des, Iso, Enf, Sev, Hal, and O2. The measurement range for N2O and O2 is 0-100 vol% with specified accuracy.
Cardiac Output (C.O.): The range is 0.1-20 L/min with an accuracy of ±5% or ±0.1 L/min. Temperature measurements (BT, IT) range from 25-43°C and 0-25°C respectively, with an accuracy of ±0.1°C.
Impedance Cardiography (ICG): Uses thoracic bio-impedance measurement with a stroke volume range of 5-50 ml/b and heart rate range of 40-250 bpm. The cardiac output range is 1.4-15 L/min with specified accuracy.
Recorder and IBP: Features a built-in thermal array recorder with 3-channel waveforms. Invasive Blood Pressure (IBP) measurement supports two channels with various pressure ranges and an accuracy of ±2% or ±1 mmHg.
Additional Information: The device is splash-proof (IPX4) for the sensor itself and supports data output for more accurate results. Technical specifications are subject to change without prior notice.
See more

Catalog excerpts

OKM 800 MULTI-PARAMETER MONITOR-1

Oicumnn Healthcare OKm800 Multi-Parameter Monitor Ideal Multi-Parameter Monitor for Monitoring of Large Intensive Care and Anesthesia Parameters from Basic Patient Parameters

 Open the catalog to page 1
OKM 800 MULTI-PARAMETER MONITOR-2

Performance Specifications 12.1” color TFT touch screen Parameters convenient for use in adult, pediatric and neonatal patients Waveform monitoring up to 9 channels Electronic keyboard on screen for inputting information Interchangeable waveform colors Ability to control all alarms from a single. Drug dose calculation program for 15 different drugs Educational demo feature OxyCRG software 3, 7 or 12 lead ECG measurement with 3, 5 or 10-electrodes ECG cable Extended arrhythmia analysis and ST segment analysis Easy monitorization with large numerical value and waveform selection Suitable monitorization...

 Open the catalog to page 2
OKM 800 MULTI-PARAMETER MONITOR-3

Interface Parameter cable interface AC power input socket Software upgrade through networking port& USB port RJ45 port Nurse call port Indicator One alarm indicator (C80) Power indicator Battery indicator QRS beep and alarm sound Operating key sound Alarm Event Recall Wave Recall NIBP Recall Trend Graph Trend Table Power-off storage Alarm Network ECG Lead Type 12-lead cable 5-lead cable 3-lead cable Lead selection Gain Selection Sweep Speed Heart Rate Range Resolution Protection Accuracy Bandwidth ST detection Arrhythmia analysis Pacemaker detection 500 groups(120hours) 6 hours 2000 groups 120...

 Open the catalog to page 3
OKM 800 MULTI-PARAMETER MONITOR-4

Temperature (Dual Channel) Range 0-50°C

 Open the catalog to page 4
OKM 800 MULTI-PARAMETER MONITOR-5

End Tidal Karbon Dioksit (EtCO2) / Respironics EtCO2(Sidestream) Technical principle Dual waveband, non-dispersive infrared (NDIR)single beam optics Initialization time Capnogram,displayed in less than 20 seconds, at an ambient temperature of 25°C, full specifications within 2 minutes CO2 measurement range 0-150 mmHg, 0-19,7%, 0-120kPa CO2 stability Sampling rate Respiratory rate range Respiratory rate accuracy Calibration Water resistance Data output 0.1mm Hg (0 to 69 mm Hg) 0.25mm Hg (70 to 150 mm Hg) 0-40mm (±2 mm Hg) 41-70mm Hg (±5% of reading) 71-100mm Hg (±8% of reading) 101-150mm Hg (±10%...

 Open the catalog to page 5
OKM 800 MULTI-PARAMETER MONITOR-6

Okuman(EtCO2)-Sidestream) Technical principle Initialization time CO2 measurement range Rise time C02 resolution CO2 accuracy CO2 stability Sampling rate Respiratory rate measurement range Dual waveband, non-dispersive infrared (NDIR) Full specifications within 3 seconds, waveform data in less than 3 seconds 0-114 mmHg, 0-15%, 0-15.2kPa Sidestream <3 s (dependent on the flow rate and the length of sampling tube) 0.1mm Hg (0 to 59 mm Hg) 0.25mm Hg (60 to 114 mm Hg) 0-40mm (±2 mm Hg) 41-76mm Hg (±5% of reading) 77-114mm Hg (±8% of reading) Respiratory rate above 80 BPM (±12% of reading ) Short-term...

 Open the catalog to page 6
OKM 800 MULTI-PARAMETER MONITOR-7

IBP Channel: Measured Pressure: Measurement Range: IBP Accuracy: Alarm Range: Multi-Gas/02 Method Gas sorts Measurement range Data output Respiratory rate Preheating time Alarm Others Infrared Absorption C02,N20,Des,lso,Enf,Sev,Hal,02 (optional paramagnetic sensor) C02 : 0-15 vol%: ±(0.2 vol% + 2 % of the reading), 15-25vol %: unspecified N2O: 0-100 vol%: ±(2 vol% + 2 % of the reading) HAL, ISO, ENF: 0-8 vol%: ±(0.15 vol% + 5 % of the reading); 8-25vol %: unspecified SEV: 0-10 vol%:±(0.15 vol% + 5 % of the reading); 10-25vol %: unspecified DES: 0-22 vol%: ±(0.15 vol% + 5 % of the reading); 22-25vol...