Introduction
The OMRON Electronic Nerve Stimulator E2 ELITE (HV-F127-E) is designed for home use to alleviate muscle and nerve pain through gentle electrical stimulation, providing relief from muscle stiffness and fatigue.
Safety Notes
Users must follow safety guidelines to prevent injuries or device malfunction. The device should not be used with pacemakers or by individuals with certain health conditions without medical consultation. It should not be applied near the heart, head, or on diseased skin.
General Information
The E2 ELITE uses electrical impulses to stimulate the body's pain-relieving mechanisms, inhibiting pain transmission and improving blood circulation. It offers nine automatic programs and four special modes for customized treatment.
Features
The device includes Quick Relief, Region, and Massage buttons for targeted treatment, along with special modes like Soft, Repeat, Point, and Wide for personalized stimulation.
Intended Use
The device is intended as a massager for relieving muscle pain, stiffness, and fatigue through electronic nerve stimulation, suitable for home use by individuals not restricted by the safety notes.
Package Contents
The package includes the main unit, electrode cord, long-life pads, batteries, electrode holder, soft fabric pouch, and an instruction manual.
High & Low-Frequency Therapy
Low-frequency therapy is effective for chronic pain and improves blood circulation, while high-frequency therapy is used for acute pain relief.
Device Components
The device consists of a main unit, electrode cord, intensity adjustment dial, and various buttons for program selection.
Usage Instructions
Instructions are provided for inserting batteries, connecting the electrode cord, and attaching the electrode pads. Users should follow these steps carefully to ensure proper device operation.
Maintenance
Guidelines for cleaning, storing, and troubleshooting the device are included to maintain its functionality and longevity.
Battery Handling and Replacement
  • Replace batteries if worn out in less than three months.
  • Remove batteries if the unit will not be used for over three months to prevent leakage.
  • Avoid mixing new and old batteries or different types of batteries.
  • Ensure correct polarity alignment when inserting batteries.
  • Dispose of used batteries according to local regulations.
Initial Setup and Electrode Cord Handling
  • Remove pads from the plastic bag without peeling off the clear film initially.
  • Avoid excessive bending and pulling of the Electrode Cord; unplug by holding the plug.
  • Contact the store or nearest OMRON dealer if the Electrode Cord is damaged.
Device Usage Instructions
  • Attach electrode pads to the desired treatment area without bending them.
  • Seek assistance for difficult-to-reach areas like the back.
  • Examples of application include shoulders, soles, calves, and lower back.
  • Turn on the device by rotating the Intensity Dial/Power Button; select treatment method (Massage, Quick Relief, Region).
  • Adjust intensity from 1 to 10; recommended treatment duration is 10-15 minutes per region, once or twice daily.
  • Store the unit properly after use to maintain pad adhesiveness.
Post-Treatment Storage
  • Turn off the power and remove the Electrode Cord Plug.
  • Peel off pads using the tab, attach them lightly to the Electrode Holder, and store in the Soft Fabric Pouch.
Maintenance and Cleaning
  • Wash pads under cold water if adhesive surface is dirty; air dry thoroughly.
  • Clean the unit with a soft cloth; avoid using benzine, thinner, or gasoline.
  • Store the unit in a cool, dry place away from direct sunlight.
Troubleshooting
  • Ensure batteries are inserted correctly if the power does not switch on.
  • Reattach pads securely if the power switches off unexpectedly.
  • Replace worn-out batteries and damaged pads as needed.
  • Adjust intensity if the stimulating effect is not felt.
Maintenance and EMC Information
Electromagnetic interference from electronic devices can affect medical devices. The EN60601-1-2:2007 standard regulates EMC requirements to prevent such issues. OMRON Healthcare's device complies with this standard. Maintain a minimum distance of 7 meters from devices generating strong electromagnetic fields.
Disposal Instructions
The product should not be disposed of with household waste. Contact retailers or local authorities for recycling information. Business users should consult suppliers for disposal terms. The product contains no hazardous substances, and battery disposal should follow national regulations.
Specifications
The device complies with the EC directive 93/42/EEC and is produced under OMRON's strict quality system. Key specifications include:
  • Model: E2 ELITE (HV-F127-E)
  • Power Supply: 3 V DC (two AAA batteries)
  • Battery Life: Approx. 3 months with new alkaline batteries
  • Frequency Generation: Approx. 1 to 1200 Hz
  • Power Consumption: Approx. 40 mA
  • Max Output Voltage: ≤ 90 V
  • Max Output Current: ≤ 10 mA
  • Operating Temperature: 10°C to 40°C
  • Storage Temperature: –20°C to 60°C
  • Dimensions: 60 x 154 x 21 mm
  • Weight: Approx. 120 g (including batteries)
See more

Catalog excerpts

E2 Elite - Instruction Manual-1

Electronic Nerve Stimulator E2 ELITE (HV-F127-E) • Electronic Nerve Stimulator. Instruction Manual. • Neurostimulateur electronique. Mode d’emploi. • Elektronischer Nervenstimulator. Gebrauchsanweisung. • Elettrostimolatore. Manuale di istruzioni. • Neuroestimulador electronico. Manual de instrucciones. • Elektronische zenuwstimulator. Gebruiksaanwijzing. • GneKTpoMaccarnep MeflMMMHCKMM, PyKOBOflCTBO no aKcnnyaTaqMM. • Elektronik Sinir Stimulatoru. Kullanim Kilavuzu,

 Open the catalog to page 1
E2 Elite - Instruction Manual-2

Instruction Manual Electronic Nerve Stimulator E2 ELITE CONTENTS 1. Before using the unit 1 Thank you for purchasing the OMRON Electronic Nerve Stimulator E2 ELITE (HV-F127-E). Please read this Instruction Manual thoroughly before using this unit, this ensures safe and correct use. Please keep this Instruction Manual always at hand for your future reference. 1.1 Notes on safety . . . . . . . . . . . . . . . . . . . . 3 1.2 General information on OMRON E2 ELITE Electronic Nerve Stimulator . . . . . . . . . . 4 1.3 Features of the product. . . . . . . . . . . . . . 4 1.4 Intended use . . . . ....

 Open the catalog to page 2
E2 Elite - Instruction Manual-3

1 .Before using the unit # The icons and warning signs are indicated here for your safety and correct usage of the product as well as to prevent injuries and/or damage to properties. • The icons and meanings are as follows: Examples of Icons The icon indicates prohibitions (must not do). Matters involving certain prohibitions are indicated by text or pictures in or near . The icon to the left means “Prohibitions to Disassemble”. Do not use this unit for purposes other than treatment indicated in this manual. May lead to accident, problems, or failure of the unit. OThe icon indicates something...

 Open the catalog to page 3
E2 Elite - Instruction Manual-4

I.Before using the unit The OMRON E2 ELITE Electronic Nerve Stimulator is an electro-therapeutic device. The E2 ELITE Electronic Nerve Stimulator enables you to reduce and relieve your pain symptoms. The treatment alleviates muscle and nerve pain through gentle stimulation. But always remember that pain also has a very important warning function, telling us that something is wrong. If you suffer from any serious illness, consult your doctor in order to confirm whether you can use the Electronic Nerve Stimulator. For active people, it provides a massaging experience which has a very beneficial...

 Open the catalog to page 4
E2 Elite - Instruction Manual-5

1 .Before using the unit The following components are included in the box. If any components are missing, please contact the nearest OMRON dealer. 3. Long-Life Pad (to be referred to as “Pad” hereafter.) One set contains two Pads. 6. Soft fabric pouch 4. AAA size (R03) batteries for § ) 1.6 Information on high & low-frequency therapy What is frequency? Frequency is the number of times electric stimulation is applied to the body per second and is represented by a unit called Hertz (Hz). I. What is Low Frequency? Although we do not notice it, our bodies generate very weak electricity from...

 Open the catalog to page 5
E2 Elite - Instruction Manual-6

1.7 Names and functions of the parts Main Unit Electrode Cord Connects the Main unit with the Pad Electrode Cord Plug Intensity Adjustment Dial/Power Button Turns on and off the power and adjusts the intensity of stimulation. Electrode Cord Jack Automatic Programmes Select one programme from each course in the treatment, region, and massage method. Quick Relief Button The programme treats the region with high frequency of 1200 Hz, which helps to relieve acute pain promptly. Region Button The unit treats the selected region with the effective programme. SPECIAL MODE Massage Button Select your...

 Open the catalog to page 6
E2 Elite - Instruction Manual-7

1 .Before using the unit Electrode Cord Plug Attach the red or the white plug to each Pad. Point & Wide Mode Wide The unit treats the red and the white sides alternately. The unit treats both the red Balance Adjustment (Switching between red and white buttons) R-button and white sides simultaneously. * Select either the Wide or the Point Button. The unit emphasizes therapy on the red side. The unit emphasizes therapy on the white side.

 Open the catalog to page 7
E2 Elite - Instruction Manual-8

2. How to use the device 2.1 How to insert batteries 1. Turn the Intensity Adjustment Dial/Power Switch to the “OFF” position. 2. Open battery cover on the back of the main unit. 3. Insert batteries according to the polarities (+ and -) shown in the battery compartment. 1.5V LR03 SIZU'AAA' OOOOOO SIZU'AAA' 1.5V LR03 OOOOOO General advice from OMRON on the handling of batteries • The supplied batteries are for the trial use only and may wear out in less than three months. • Replace the worn batteries with new ones immediately. • If you are not going to use the unit for more than three months,...

 Open the catalog to page 8
E2 Elite - Instruction Manual-9

2.3 How to attach the electrode pads Attach each Pad to the region you want to treat without bending it. When using the unit for the first time A clear plastic film is attached to the Pads. As the Pads have strong adhesiveness, peel off the clear plastic film from the Pads and attach the Pads to the region you want to receive treatment. * Discard the peeled off clear film as it should not be used anymore. * It may be difficult for you to attach the Pads on your back such as shoulders or lower back. It is a good idea to ask someone to help you. Attach the Pads close to the skin. * If the Pads...

 Open the catalog to page 9
E2 Elite - Instruction Manual-10

Calf Swelling and fatigue of the Calf is presumably caused by congestion of blood and accumulation of fatigue substances in that region. Attach the Pads to upper and lower calf. Waist (Lower Back) Back pain is caused by various reasons. The type of back pain that can be treated by low-frequency therapy includes stiffness of the lower back, muscle pain, and neuralgia (nerve pain). Attach the Pads symmetrically to the regions you feel pain with the backbone as the center. It is effective to attach the Pads to the shaded regions of lower back as shown in the diagram. It is effective to attach the...

 Open the catalog to page 10
E2 Elite - Instruction Manual-11

stimulation. Select your favorite intensity level from 1 to 10 by rotating the Intensity Dial/Power Button. Standard for treatment. Duration: 10 to 15 minutes per region for each treatment. Number of treatment times: Once or twice a day. Intensity: As high as you feel comfortable when using this unit. 1 SPECIAL MODE ELECTRONIC NERVE STIMULATOR ends, turn off the power. ck Cli Rotate the Intensity Dial/Power Button upwards. When you hear a click, the power is turned off. * The power will be turned off automatically in approximately 15 minutes after the treatment starts. Even when the power is...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.