Operating Parameters
The OPTI CCA-TS analyzer requires a minimum sample size of 125 µL, with a B60 cassette needing only 60 µL. It can analyze whole blood, plasma, or serum, depending on the analyte. The sample is applied via syringe, capillary, or ComfortSampler™ and is automatically aspirated. Results are available in less than 120 seconds. The device operates in ambient temperatures of 10°C to 32°C and relative humidity of 5% to 95% (non-condensing). It supports multiple languages including English, Spanish, French, and others.
Security Features
The analyzer setup, operation, and delete functions are password protected. It includes user-definable QC lockout functions and can store up to 300 operator IDs with associated PINs.
Miscellaneous Specifications
The device dimensions are 124 H x 362 W x 230 D mm, weighing 5.5 kg with a rechargeable battery pack. It operates on 120 or 240 AC/50-60 Hz with a maximum power consumption of 110 VA. Interfaces include Ethernet and Serial (ASTM or ASCII), and it holds CE, UL, and IVDD approvals.
Measured Parameters
The analyzer measures a range of parameters including pH, PCO2, PO2, tHb, SO2, Na+, K+, iCa, Cl-, Glucose, BUN, Lactate, and Barometric Pressure, each with specific ranges and resolutions.
Calculated Parameters
It calculates parameters such as Actual Bicarbonate, Standard Bicarbonate, Base Excess, Buffer Base, Standard pH, Hydrogen Ion Concentration, Total CO2, Oxygen Saturation, Oxygen Content, and others.
Technology and Features
The OPTI CCA-TS uses patented optical fluorescence technology, requiring no daily maintenance and having no tubing, electrodes, or reagents to replace. It features automatic sample aspiration, bubble and clot detection, and a color touch screen for ease of use. The device is cost-effective with low fixed operating costs and uses electronic QC.
Compliance and Data Management
The analyzer supports compliance with user-definable QC lockout, password protection, and maintenance logs. It offers optional data management with the Prism POC data manager and online Quality Assurance Program (QAP).
Customer Feedback
Customers praise the OPTI CCA-TS for its reliability, ease of use, and excellent customer service. It is noted for its performance in cold operating rooms and accurate glucose measurements.
See more

Catalog excerpts

OPTI LION Stat Electrolyte Analyzer brochure-1

Portable Blood Gas Analyzer with Optical Fluorescence Technology To learn more, contact OPTI Medical today at 800.490.6784 or 770.510.4444 or visit our website at: www.optimedical.com MEASURED PARAMETERS pH PCO2 PO2 tHb SO2 Na+ K+ iCa ClGlucose BUN (Urea) Lactate Barometric Pressure CALCULATED PARAMETERS Actual Bicarbonate (HCo3) Standard Bicarbonate (st.HCO3) Base Excess (BE) Base Excess Extra Cellular Fluid (BEecf) Base Excess Actual (BEact) Buffer Base (BB) Standard pH (st.pH) Hydrogen Ion Conc. (cH+) Total CO2 (tCO2) Oxygen Saturation (SO2) Oxygen Content (O2 ct) Alveolar-arterial O2 Conc. (AaDO2) P50 St. Ionized Calcium (pH=7.4)(nCa++) Hematocrit (Hct) INPUT PARAMETERS Operator ID (11 Digits) Patient ID (15 Digits) Accession Number (12 Digits) 3 User Defined Fields (9 Digits) Patient Temperature Date of Birth Patient Sex Hemoglobin Type Puncture Site Bypass Sample Type Total Hemoglobin MCHC O2 Mode FIO2 P50 Vent Mode TVol MVol PIP Pplat PS PEEP CPAP Rate Flow Rate I/E ratio Bi Level Pressure RQ Optical Fluorescence BLOOD GAS & ELECTROLYTE SYSTEMS OPERATING PARAMETERS Minimum Sample Size: 125 µL; B60 cassette – 60 µL Sample Type: Whole Blood, Plasma, or Serum (depends on analyte tested) Sample Application: Syringe, Capillary or ComfortSampler™ Sample Input: Automatic Aspiration Analysis Time (Time to Results): < 120 Seconds Ambient Temperature: 10° C - 32° C (50°F - 90°F) Relative Humidity: 5% - 95% (Non-Condensing) Available Languages: English, Spanish, French, Italian, German, Japanese, Chinese, Polish, Portuguese SECURITY Password: Password Protected Analyzer Setup, Operation and Delete Functions QC Lockout: User Definable QC Lockout Functions Operator IDs: Storage for 300 Operator IDs (11 Digits) and Associated PIN (4 Digits) MISCELLANEOUS Size 124 H x 362 W x 230 D mm (4.7 H x 14.2 W x 9.1 D in) Weight: 5.5 kg (12 lbs) with rechargeable Battery Pack Voltage/Frequency: 120 or 240 AC/50-60 Hz Power Consumption (Max.): 110 VA Interface: Ethernet, Serial (ASTM or ASCII) Approvals: CE, UL, IVDD OPTI Medical Systems, Inc. 235 Hembree Park Drive Roswell, Georgia 30076 USA + 1-770-510-4444 or 800-490-6784 www.optimedical.com OPTI, ComfortSampler, and the OPTI Medical logo are trademarks or registered trademarks of OPTI Medical Systems, Inc, in the United States and/or other countries. OPTI Medical’s privacy policies can be viewed at www.optimedical.com. ©2011 OPTI Medical Systems, Inc. PM0058 Rev D Portable Blood Gas Analyzer

 Open the catalog to page 1
OPTI LION Stat Electrolyte Analyzer brochure-2

Improving efficiency through reliability. Portable Blood Gas Analyzer RS232/Ethernet/Compact Flash Port (rear) Allows for simple upload of data to a compact flash card, transfer of data to a data manager, and easy software upgrades. Color Touch Screen Intuitive icons and step by step prompts reduce training requirements. Spend less time on maintenance Increase the productivity in your department and significantly reduce your operational cost. The OPTI CCA-TS analyzer uses a unique, patented optical fluorescent technology that minimizes maintenance. The OPTI CCA-TS analyzer requires no daily maintenance...