REVO 80

REVO 80

REVO 80

Product catalog summary
Introduction
The document introduces the REVO 80, a state-of-the-art Spectral Domain OCT instrument designed for simplicity and advanced functionality. It emphasizes ease of use, requiring only the pressing of a start button to begin examinations, and highlights its compact design suitable for small spaces.

Key Features
  • Advanced Imaging: The REVO 80 offers high-quality OCT imaging with noise reduction technology and AI-enhanced tomograms for detailed analysis.
  • Comprehensive Analysis: It provides full functionality from retina to cornea, allowing measurement, quantification, and tracking of changes over time.
  • Networking and Integration: The device supports DICOM and EMR integration, facilitating efficient data management and patient education.

Functional Capabilities
  • Retina and Glaucoma Analysis: A single 3D scan performs both analyses, with automatic recognition of retinal layers for precise diagnosis.
  • Angiography: Non-invasive technique for visualizing retinal microvasculature, with options for high-detail imaging over large fields.
  • Glaucoma Tools: Includes comprehensive tools for nerve fiber layer and ganglion layer analysis, aiding in early detection and monitoring.
  • Corneal Topography: Provides detailed curvature maps and keratoconus screening, with customizable views and automatic capturing.
  • Anterior Chamber Imaging: Built-in lens for anterior segment imaging without additional equipment.
  • Biometry OCT: Measures ocular structures along the eye axis, with visual verification of measurements.

Technical Specifications
The document lists detailed technical specifications, including scanning speed, resolution, connectivity options, and power requirements. It also notes optional software modules and hardware features.

Conclusion
The REVO 80 is presented as a versatile and efficient OCT device suitable for modern practices, offering advanced diagnostic capabilities and seamless integration into existing systems.
See more

Catalog excerpts

REVO 80-2

lution starts again Our supreme experience in Spectral Domain OCT allows us to provide the market with a state of the art instrument which comes with new advanced technologies and remarkable simplicity of operation. The REVO 80 will expand the daily demands of any modern practice. OCT made simple as never before Position the patient and press the START button to acquire examinations of both eyes. The Revo 80, guides the patient through the process with vocal messages to increase comfort and reduce patient chair time. New OCT standard - All functionality In One device. Once again REVO goes beyond...

 Open the catalog to page 2
REVO 80-3

A single 3D Retina scan performs both Retina and Glaucoma analysis. The software automatically recognizes 8 retinal layers which assists with precise diagnosis and mapping of any changes in the patient’s condition. A variety of result analysis and presentation methods allows the most suitable selection to increase efficiency. REVO’s standard high density scanning capability and blood vessel structure recognition enable a precise alignment of past and current scans. The operator can analyse changes in morphology, quantified progression maps and evaluate the progression trends. Progression Morphology...

 Open the catalog to page 3
REVO 80-4

lution starts again This non-invasive dye free technique allows the visualization of the microvasculature of the retina. Both blood flow and structural visualization give additional diagnostic information about many retinal diseases. Angiography scan allows assessment of the structural vasculature of the macula, the periphery or the optic disc. Extremely short scanning times of 1,6 seconds in standard resolution or 3 seconds in high resolution. Now Angiography OCT can become a routine in your diagnostic practice. The Angiography mosaic delivers high-detail images over a large field of the retina....

 Open the catalog to page 4
REVO 80-5

Comprehensive glaucoma analytical tools for quantication of the Nerve Fiber Layer, Ganglion layer and Optic Head with DDLS enable the user to perform precise diagnosis and monitoring of glaucoma over time. With the Asymmetry Analysis of Ganglion layers between hemispheres and between eyes it is possible to identify and detect glaucoma in early stages and in non-typical patients. Invaluable combination of information about the functional quality of vision with comprehensive data on retinal Ganglion Cells, RNFL and Optic Nerve Head for both eyes on a single report page. The S&F report contains...

 Open the catalog to page 5
REVO 80-6

lution starts again ANTERIOR CHAMBER Built-in anterior lens allows the user to perform the imaging of the anterior segment without installing additional lens or forehead adapter. Now you can display the whole anterior segment or focus on a small area to bring out the details of the image. Anterior Chamber exam with a fast view of the whole Anterior Chamber make the evaluation of gonioscopy situation and the verification of cataract lens easier and faster. For all anterior examination, no additional lens is required. This allows the examiner to quickly complete the scanning procedure. * Images...

 Open the catalog to page 6
REVO 80-7

Choroidal observation Wide Central scan Sclera and Anterior Structure Cornea wide scan

 Open the catalog to page 7
REVO 80-8

TECHNICAL SPECIFICATION Technology Light source Scanning speed Axial resolution Transverse resolution Overall scan depth Focus adjustment range Scan range 80 0005 / 60 000 measurements per second 2.6 μm digital, 5 μm in tissue 12 μm, typical 18 μm 2.8 mm / ~6 mm in Full Range mode -25 D to +25 D Posterior 5 mm to 15 mm, Angio 3 mm to 6 mm, Anterior 3 mm to 18 mm 3D, Angio1, Full Range Radial, Full Range B-scan, Radial, B-scan, Raster, Cross Scan types Fundus image Live Fundus Reconstruction Retina analysis Retina thickness, Inner Retinal thickness, Outer Retinal thickness, RNFL+GCL+IPL thickness,...

 Open the catalog to page 8

All Optopol Technology catalogs and technical brochures

  1. REVO NX 130

    16  Pages

  2. REVO 60

    8  Pages

  3. REVO FC 130

    16  Pages

Archived catalogs

  1. revo-fc130

    16  Pages

  2. REVO FC

    6  Pages

  3. REVO NX

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.