TECHNICAL SPECIFICATIONS Image Types optomap plus (red and green laser): Colour Composite View Green Laser View Red Laser View optomap af (green laser): Autofluorescence (optional) Resolution optomap plus: 14 µm Wavelengths Red laser: 635 nm Green laser: 532 nm Exposure Time Foot Print Weight Table Space Requirements Colours Laser Class System Voltage Less than 0.4 seconds Width: 440 mm/18 in Depth: 500 mm/20 in Height: 795 mm/32 in 28 kg/62 lbs Width: 900 mm/36 in Depth: 600 mm/24 in Variety of colours, see optosnextgen.com Laser safety class-1 following EN60825 EU/AU: 200-240V at 50/60Hz, 1.5A Power Consumption Optos has more than 250 completed and ongoing clinical studies supporting our commitment to the belief that an ultra-widefield view of the retina helps eye care professionals provide the best care for their patients. More than 5,000 devices are installed worldwide and more than 39 million patients have received an optomap® . Optos plc Queensferry House Carnegie Campus Enterprise Way Dunfermline, Fife Scotland KY11 8GR Tel: +44 (0)1383 843300 info@optos.com Optos North America 67 Forest Street Marlborough, MA 01752 USA Call Toll-free (US & Canada): 1-800-854-3039 Outside of the US: +1 508 787 1400 usinfo@optos.com Optos Australia 10 Myer Court Beverley South Australia 5009 Tel: +61 8 8443 4533 auinfo@optos.com © 2013 Optos. All rights reserved. Optos, optos and optomap are registered trademarks of Optos plc. Registered in Scotland Number: SC139953 Registered Office: Queensferry House, Carnegie Campus, Dunfermline, Fife KY11 8GR, UK Building The Retina Company Optos 4_color Logo Optos Dark Blue c100m86y26k21
Open the catalog to page 1PIONEERING TECHNOLOGY Optos’ patented ultra-widefield digital scanning laser technology acquires images that support the detection, diagnosis, analysis, documentation and management of ocular pathology and systemic disease that may first present in the periphery. These conditions may otherwise go undetected using traditional examination techniques and equipment. Simultaneous, non-contact, central pole-to-periphery views of up to 82% or 200 degrees of the retina are displayed in one single capture, compared to 45 degrees achieved with conventional methods. The newest addition to the Optos...
Open the catalog to page 2PIONEERING TECHNOLOGY Optos’ patented ultra-widefield digital scanning laser technology acquires images that support the detection, diagnosis, analysis, documentation and management of ocular pathology and systemic disease that may first present in the periphery. These conditions may otherwise go undetected using traditional examination techniques and equipment. Simultaneous, non-contact, central pole-to-periphery views of up to 82% or 200 degrees of the retina are displayed in one single capture, compared to 45 degrees achieved with conventional methods. The newest addition to the Optos...
Open the catalog to page 3TECHNICAL SPECIFICATIONS Image Types optomap plus (red and green laser): Colour Composite View Green Laser View Red Laser View optomap af (green laser): Autofluorescence (optional) Resolution optomap plus: 14 µm Wavelengths Red laser: 635 nm Green laser: 532 nm Exposure Time Foot Print Weight Table Space Requirements Colours Laser Class System Voltage Less than 0.4 seconds Width: 440 mm/18 in Depth: 500 mm/20 in Height: 795 mm/32 in 28 kg/62 lbs Width: 900 mm/36 in Depth: 600 mm/24 in Variety of colours, see optosnextgen.com Laser safety class-1 following EN60825 EU/AU: 200-240V at 50/60Hz,...
Open the catalog to page 4All Optos catalogs and technical brochures
-
V² Vantage Pro
2 Pages
-
ONE SOLUTION
4 Pages
-
Daytona plus
4 Pages
-
Monaco
4 Pages
-
California Brochure
4 Pages