TRENDvent
2Pages

{{requestButtons}}

Catalog excerpts

TRENDvent - 1

PR-TRENDvent-eng-0610-03.pdf 1 21.01.2011 09:53:14 Dimensions (w x h x l) 330 mm x 110 mm x 280 mm Mass 4,2 kg Power Supply 100 V - 250 V AC, 50 - 60 Hz; 24 V DC / 5 A Internal Battery Lithium-Ion-Rechageable, 24 V; 2.3 Ah Average Power Consumption. 52 W Noise Level < 30 dB(A) overall < 25 dB(A) at 10 hPa Parameters PCV/APCV PSV CPAP S ST T IPAP 4 - 40 hPa 4 - 40 hPa 2 - 20 hPa 4 - 40 hPa 4 - 40 hPa 4 - 40 hPa PEEP 0 - 20 hPa 0 - 20 hPa 2 - 20 hPa 2 - 20 hPa 2 - 20 hPa Frequency 4 - 50 bpm 4 - 50 bpm; Off 4 - 50 bpm 4 - 50 bpm Insp.Time 0,3 - 8,0 s EPAP TRENDvent Technical Data Accessories The functional bag was developed especially for the ventilator TRENDvent. Through the bag window, the functions of the device can be controlled. For the accessories an enlargeable compartment with separat space for the humidifier is integrated. The wide belts care for a good wearing comfort as backpack or sling bag. Many attachment features at the bag allow an easy assembly at wheel chair. The external rechargable battery is intended as autonomous power supply for all HOFFRICHTER ventilators including TRENDvent. It was especially developed for homecare use, use in hospitals and effort in mobile use. The rechargable battery enables an additonal using time of 12 hours (in standard adjustments). 0,3 - 8,0 s Apnoea Limit Off; 3 - 60 s; Off; 3-60 s Auto [as alarm] 1-5 1-5 1-5 1-5 1 - 5; Auto 1 - 5; Auto Off; 1 - 5; Auto Ramp 1-5 Insp.Trigger Off; 1 - 5; Auto 1 - 5; Auto 3 - 60 s; Auto Exp.Trigger 10 - 90%; Auto 10 - 90%; Auto 10 - 90%; Auto Max. Insp.Time 1 - 10 s 1 - 10 s The remote alarm box is a wire alarm system signalling alarms of the TRENDvent for home use. The alarm is generated by the ventilator which is not within the operator’s immediate hearing range. There is no difference between alarm type and alarm priority in alarm signalling. 1 - 10 s Vt. min. 0.05 - 2 l; Off 0.05 - 2 l; Off 0.05 - 2 l; Off 0.05 - 2 l; Off 0.05 - 2 l; Off Add. Pressure 3 - 10 hPa 3 - 10 hPa 3 - 10 hPa 3 - 10 hPa 3 - 10 hPa The FiO2-Sensor-Set measures the oxygen at the air outlet of the ventilator which shows the actual value in the display of the device. Alarm Parameters Max. Volume 0.2 - 2.5 l; Off 0.2 - 2.5 l; Off 0.2 - 2.5 l; Off 0.2 - 2.5 l; Off 0.2 - 2.5 l; Off 0.2 - 2.5 l; Off Min.Volume 0.01- 2 l; Off 0.01- 2 l; Off 0.01- 2 l; Off 0.01- 2 l; Off 0.01- 2 l; Off 0.01- 2 l; Off 10 - 120 bpm; 10 - 120 bpm; 10 - 120 bpm; 10 - 120 bpm; 10 - 120 bpm; Off Off Off Off Off Max. Frequency 10 - 120 bpm; Off Max. Oxygen 30 - 100 %; Off 30 - 100 %; Off 30 - 100 %; Off 30 - 100 %; Off 30 - 100 %; Off 30 - 100 %; Off Min. Oxygen 18 - 90 %; Off Pres. Difference 1 - 10 hPa Leakage 18 - 90 %; Off 18 - 90 %; Off 18 - 90 %; Off 18 - 90 %; Off 1 - 10 hPa 1 - 10 hPa 1 - 10 hPa 1 - 10 hPa AquaTREND uni, the optional therapy air humidifier is able to be adjusted quickly with only one click. Easy cleaning and a large filling volume (300 ml) increases the user friendliness. An ingenious air-guidance system prevents water from getting into the therapy device. 18 - 90 %; Off 1 - 10 hPa 20 - 200 l/min; 20 - 200; l/min; 20 - 200; l/min; 20 - 200; l/min; 20 - 200; l/min; 20 - 200; l/min; Off Off Off Off Off Off Specifications and Performance Max. Stable Pressure Limit 60 hPa Max. Working Pressure 40 hPa Min. Stable Pressure Limit 0 hPa Min. Working Pressure Max. Flow 250 l/min 0 hPa Technical Requirements for Accessories Oxygen Inlet: Bacterial Filter: Type of Connection Port Quick Coupling Connections 22 / 15 mm Cone (according to EN 1281-1) Manufacturer: Pressure < 1000 hPa Resistance < 2.3 hPa at 60 l/min Flow < 15 l/min CE-Mark required! Sales: HOFFRICHTER GmbH Mettenheimer Straße 12/14 19061 Schwerin Germany Phone: +49 385 39925 0 Fax: +49 385 39925-25 E-Mail: info@hoffrichter.de www.hoffrichter.de Technical specifications are subject to technical modifications. PR-TRENDvent-eng-0610-03 For more noblesse

Open the catalog to page 1
TRENDvent - 2

PR-TRENDvent-eng-0610-03.pdf 2 21.01.2011 09:53:16 TRENDvent • Usage of Leakage- and Valve Tubing Systems With an easy switching, the system can be used with a leakage circuit or a valve circuit. PCV Pressure Controlled Ventilation • The ventilation archetype is pressure- and time-controlled. Airway Pressure IPAP controlled inspiration controlled inspiration controlled inspiration PEEP The wide, big handle guarantees an easy transport of the device. PCV - Pressure Controlled Ventilation • If the trigger is active ((A)PCV), the patient can request additionnal controlled inspiration breathes....

Open the catalog to page 2

All Orbisana catalogs and technical brochures

  1. point 2

    2 Pages

  2. CARAT pro

    2 Pages

  3. Masquerade

    2 Pages

  4. CARAT Pro

    2 Pages

  5. AUTOFLEX

    2 Pages

  6. Comfort Tube

    2 Pages

  7. Acessories

    2 Pages

  8. TREND 500

    2 Pages

  9. AKKUPACK uni

    2 Pages

  10. point 2

    2 Pages

  11. PasCal CPS

    4 Pages

  12. VECTOR et

    2 Pages

  13. PasCal

    12 Pages

  14. CARAT

    2 Pages

  15. TREND II

    2 Pages