
Catalog excerpts

Your healthcare, we care. A9600 Anesthesia Workstation Technical Parameters ·Volume Control - Intermittent Positive Pressure Ventilation (IPPV) ·Pressure Control Ventilation (PCV) ·Synchronized Intermittent Mandatory Ventilation with Pressure Support (SIMV + PS) ·Pressure Support with Apnea backup (PS) ·Manual ·Apnea ·Apnea CO 2 ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Continuous Pressure ·O 2 Supply Fail ·Negative Pressure ·High Breath Rate (PS) ·High PEEP ·Mixed Agents ·Low Battery ·AC Power Fail ·Technical alarms Parameters and Ranges ·Pressure target: 5 – 70 cmH 2 O ·Pressure support (delta P): 3 – 50 cmH 2 O ·Tidal Volume: 20 – 1500 mL ·Breathing Freq.: 4-100 bpm 2-60 bpm in PS, SIMV ·T INSP : 0.2-5.0s ·PEEP: OFF, 3 - 30 cmH 2 O ·Freq MIN : 2 - 60 bpm ·T pause: OFF, 5%-60% ·Trigger: 1 – 15 L/min ·I:E Ratio: 4:1-1:8 ·T SLOPE : 0 – 2 s ·Vaporizers: Sevoflurane, Desflurane, Isoflurane, Halothane, Enflurane Monitoring Continuous monitoring of inspiratory O 2 concentration, breathing frequency, airway pressure (Paw, Peak, Pmean, PEEP), minute volume and tidal volume. The measured parameters are displayed as large, easy to read digital values. Airway pressure, flow and CO 2 (optional) are shown in graphical waveforms. Optional Gas Monitoring for CO 2 and 5 Anesthetic Agents with Agent Identification Inspiratory O 2 concentration (FiO 2 ) Minute Volume (MV) Airway pressure (PAW) EtCO 2 and agents Operation Conditions: ·Operating voltage: AC100-240V, 50Hz/60Hz ·Temperature: -20 - 50 ℃ ·Relative humidity: 15~95%, non-condensing (operating) ·Weight (without vaporizer & cylinders): approx. 120Kg ·Dimensions (H x W x D): approx. 1400mmX760mmX760mm Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA AL9000 September 2012
Open the catalog to page 1
A9600 Anesthesia Workstation A9600 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation. It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician. A9600 includes Adult and Child modes that provide patient-appropriate defaults and ranges. A9600 has VCV, PCV and SIMV+PS automatic ventilation modes providing flexibility in your choice of ventilation strategy. It is suitable for pediatric and adult operation. A9600 is filled with many...
Open the catalog to page 2
A9600 Anesthesia Workstation A9600 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation. It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician. A9600 includes Adult and Child modes that provide patient-appropriate defaults and ranges. A9600 has VCV, PCV and SIMV+PS automatic ventilation modes providing flexibility in your choice of ventilation strategy. It is suitable for pediatric and adult operation. A9600 is filled with many...
Open the catalog to page 3
A9600 Anesthesia Workstation A9600 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation. It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician. A9600 includes Adult and Child modes that provide patient-appropriate defaults and ranges. A9600 has VCV, PCV and SIMV+PS automatic ventilation modes providing flexibility in your choice of ventilation strategy. It is suitable for pediatric and adult operation. A9600 is filled with many...
Open the catalog to page 4
Your healthcare, we care. A9600 Anesthesia Workstation Technical Parameters ·Volume Control - Intermittent Positive Pressure Ventilation (IPPV) ·Pressure Control Ventilation (PCV) ·Synchronized Intermittent Mandatory Ventilation with Pressure Support (SIMV + PS) ·Pressure Support with Apnea backup (PS) ·Manual ·Apnea ·Apnea CO 2 ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Continuous Pressure ·O 2 Supply Fail ·Negative Pressure ·High Breath Rate (PS) ·High PEEP ·Mixed Agents ·Low Battery ·AC Power Fail ·Technical alarms Parameters and...
Open the catalog to page 5
Your healthcare, we care. A9600 Anesthesia Workstation Technical Parameters ·Volume Control - Intermittent Positive Pressure Ventilation (IPPV) ·Pressure Control Ventilation (PCV) ·Synchronized Intermittent Mandatory Ventilation with Pressure Support (SIMV + PS) ·Pressure Support with Apnea backup (PS) ·Manual ·Apnea ·Apnea CO 2 ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Continuous Pressure ·O 2 Supply Fail ·Negative Pressure ·High Breath Rate (PS) ·High PEEP ·Mixed Agents ·Low Battery ·AC Power Fail ·Technical alarms Parameters and...
Open the catalog to page 6All Oricare catalogs and technical brochures
-
V8600 Ventilator
6 Pages
-
L2700 Series
6 Pages
-
T3600
16 Pages
-
T3600 Operating Table
8 Pages
-
P1000 Series
12 Pages
-
Anesthetic A9040 Vaporizer
2 Pages
-
C4500 Medical Air Compressor
2 Pages
-
V8800
6 Pages
-
A9800
6 Pages
-
M7600/M7400
6 Pages
-
M7800
6 Pages
-
V8800 Ventilator System
2 Pages
Archived catalogs
-
T3600 Operating Table
6 Pages
-
A9600 Anesthesia Workstation
2 Pages