1. Catalogs
  2. Oricare
  3. A9800 Anesthesia Workstation (Non-USA)

A9800 Anesthesia Workstation (Non-USA)

A9800 Anesthesia Workstation (Non-USA)

A9800 Anesthesia Workstation (Non-USA)

Product catalog summary
Overview: The A9800 Anesthesia Workstation is an advanced, user-friendly device designed for accurate, pneumatically driven, and electronically controlled ventilation. It supports a wide range of ventilation modes and is equipped with sophisticated monitoring and safety features.
Ventilation Modes: The workstation supports multiple ventilation modes including Volume Controlled Ventilation (VCV), Pressure Controlled Ventilation (PCV), Synchronized Intermittent Mandatory Ventilation with Pressure Support (SIMV + PS), Pressure Support with Apnea Backup, Pressure Controlled Ventilation with Volume Guarantee (PCV-VG), and Manual Ventilation.
Alarms: The system includes various alarms for apnea, CO2 levels, inspiratory O2 concentration, minute volume, airway pressure, EtCO2, continuous pressure, O2 supply failure, negative pressure, high breath rate, high PEEP, mixed agents, low battery, AC power failure, and technical issues.
Operational Conditions: The workstation operates at AC100-240V, 50Hz/60Hz, within a temperature range of 10-40℃, and a relative humidity of ≤90%. It weighs approximately 140Kg and measures 1400mm x 900mm x 760mm.
Standards and Monitoring: It complies with EN 60601-1, EN 60601-1-2, ISO 80601-2-13 standards. Continuous monitoring includes inspiratory O2 concentration, breathing frequency, airway pressure, minute volume, and tidal volume, with digital and graphical displays.
Parameters and Ranges: Key parameters include pressure target (5-70 cmH2O), pressure support (3-50 cmH2O), tidal volume (20-1500 mL), breathing frequency (2-100 bpm), PEEP (OFF, 3-30 cmH2O), and I:E Ratio (4:1 – 1:8).
Features: The workstation features a 15” TFT LCD touch screen, electronic flow meters, data communication support, and a variety of advanced features for therapy delivery. It includes a heated breathing system, autoclaveable components, and an absorber by-pass function.
Additional Options: Options include gas monitoring for CO2, N2O, and anesthetic agents, an Anesthetic Gas Scavenging System (AGSS), patient suction regulator, and a third vaporizer parking position.
Safety and Usability: The system ensures a minimum of 25% O2 concentration, features a large stainless worktable, auxiliary oxygen flow meter, and an Air/O2 Blender. It also includes GCX-type rails, gas supply pressure gauges, and locking drawers for storage.
See more

Catalog excerpts

A9800 Anesthesia Workstation (Non-USA)-1

A9800 Anesthesia Workstation Technical Parameters Alarms ·Apnea ·Apnea CO 2 ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Continuous Pressure ·O 2 Supply Fail ·Negative Pressure ·High Breath Rate (PS) ·High PEEP ·Mixed Agents ·Low Battery ·AC Power Fail ·Technical alarms Ventilation Modes ·Volume Controlled Ventilation (VCV) ·Pressure Controlled Ventilation (PVC) ·Synchronized Intermittent Mandatory Ventilation w / Pressure Support (SIMV + PS) with Volume or Pressure-type mandatory breaths ·Pressure Support (PS) with Apnea Backup ·Pressure Controlled Ventilation with Volume Guarantee (PCV-VG) ·Manual Ventilation Parameters and Ranges ·Pressure target: 5 – 70 cmH 2O ·Pressure support (delta P): 3 – 50 cmH 2O ·Tidal Volume: 20 – 1500 mL ·Breathing Freq.: 2 – 100 bpm 2 – 60 bpm in PS 2 – 100 bpm in SIMV-VC and SIMV-PC 4 – 100 bpm in other modes ·TINSP: 0.2 – 5.0 s ·PEEP: OFF, 3 – 30 cmH 2O ·FreqMIN: 2 – 60 bpm ·Tpause: OFF, 5% – 60% ·Trigger: 1 – 15 L/min ·I: E Ratio: 4 :1 – 1: 8 ·TSLOPE: 0 – 2 s ·Vaporizers: Sevoflurane, Desflurane, Isoflurane, Halothane, Enflurane Inspiratory O 2 concentration (FiO 2) Minute Volume (MV) Airway pressure (PAW) EtCO 2 and agents Anesthesia Workstation Operation Conditions ·Operating voltage: ·Temperature: AC100-240V, 50Hz / 60Hz 10 - 40℃(operation) -20 - 60℃(storage &transport) ·Relative humidity: 90%, non-condensing (operation); 90%, non-condensing (storage &transport) ·Weight (without vaporizer & cylinders): approx. 140Kg ·Dimensions (H x W x D): approx. 1400mm x 900mm x 760mm Monitoring ·Continous monitoring of inspiratory O 2 concentration, breathing frequency, airway pressure (Ppeak, Plat, Pmean, PEEP), minute volume and tidal volume. ·The measured parameters are displayed as large, easy to read digital values. Airway pressure, flow, volume and CO 2 (optional) are shown in graphical waveforms. Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA AL9017 Jun. 2014 0123 Tel: -1-215-538-2470 Fax: -1-215-538-2578 [email protected] www.oricaremed.com Rx Only

 Open the catalog to page 1
A9800 Anesthesia Workstation (Non-USA)-2

A9800 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation. It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician. A9800 provides complete anesthesia ventilation capabilities that include traditional and “intensive-care type” ventilation modes like PCV-VG (volume guarantee). Low-flow anesthesia delivery creates savings by lowering facility gas usage. Sophisticated ventilation capabilities of A9800 will meet the needs of the full patient...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.