Catalog excerpts

A9800 Anesthesia Workstation Technical Parameters Alarms ·Apnea ·Apnea CO 2 ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Continuous Pressure ·O 2 Supply Fail ·Negative Pressure ·High Breath Rate (PS) ·High PEEP ·Mixed Agents ·Low Battery ·AC Power Fail ·Technical alarms Ventilation Modes ·Volume Controlled Ventilation (VCV) ·Pressure Controlled Ventilation (PVC) ·Synchronized Intermittent Mandatory Ventilation w / Pressure Support (SIMV + PS) with Volume or Pressure-type mandatory breaths ·Pressure Support (PS) with Apnea Backup ·Pressure Controlled Ventilation with Volume Guarantee (PCV-VG) ·Manual Ventilation Parameters and Ranges ·Pressure target: 5 – 70 cmH 2O ·Pressure support (delta P): 3 – 50 cmH 2O ·Tidal Volume: 20 – 1500 mL ·Breathing Freq.: 2 – 100 bpm 2 – 60 bpm in PS 2 – 100 bpm in SIMV-VC and SIMV-PC 4 – 100 bpm in other modes ·TINSP: 0.2 – 5.0 s ·PEEP: OFF, 3 – 30 cmH 2O ·FreqMIN: 2 – 60 bpm ·Tpause: OFF, 5% – 60% ·Trigger: 1 – 15 L/min ·I: E Ratio: 4 :1 – 1: 8 ·TSLOPE: 0 – 2 s ·Vaporizers: Sevoflurane, Desflurane, Isoflurane, Halothane, Enflurane Inspiratory O 2 concentration (FiO 2) Minute Volume (MV) Airway pressure (PAW) EtCO 2 and agents Anesthesia Workstation Operation Conditions ·Operating voltage: ·Temperature: AC100-240V, 50Hz / 60Hz 10 - 40℃(operation) -20 - 60℃(storage &transport) ·Relative humidity: 90%, non-condensing (operation); 90%, non-condensing (storage &transport) ·Weight (without vaporizer & cylinders): approx. 140Kg ·Dimensions (H x W x D): approx. 1400mm x 900mm x 760mm Monitoring ·Continous monitoring of inspiratory O 2 concentration, breathing frequency, airway pressure (Ppeak, Plat, Pmean, PEEP), minute volume and tidal volume. ·The measured parameters are displayed as large, easy to read digital values. Airway pressure, flow, volume and CO 2 (optional) are shown in graphical waveforms. Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA AL9017 Jun. 2014 0123 Tel: -1-215-538-2470 Fax: -1-215-538-2578 info@oricaremed.com www.oricaremed.com Rx Only
Open the catalog to page 1
A9800 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation. It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician. A9800 provides complete anesthesia ventilation capabilities that include traditional and “intensive-care type” ventilation modes like PCV-VG (volume guarantee). Low-flow anesthesia delivery creates savings by lowering facility gas usage. Sophisticated ventilation capabilities of A9800 will meet the needs of the full...
Open the catalog to page 2All Oricare catalogs and technical brochures
-
V8600 Ventilator
6 Pages
-
L2700 Series
6 Pages
-
T3600
16 Pages
-
T3600 Operating Table
8 Pages
-
P1000 Series
12 Pages
-
Anesthetic A9040 Vaporizer
2 Pages
-
A9600 Anesthesia Workstation
6 Pages
-
C4500 Medical Air Compressor
2 Pages
-
V8800
6 Pages
-
A9800
6 Pages
-
M7600/M7400
6 Pages
-
M7800
6 Pages
-
V8800 Ventilator System
2 Pages
Archived catalogs
-
T3600 Operating Table
6 Pages
-
A9600 Anesthesia Workstation
2 Pages