Overview: The Oricare L2700 Series Operating Room Lamps utilize advanced LED technology to provide superior surgical lighting. These lamps offer low infrared and UV-free radiation, reducing tissue desiccation and promoting faster post-surgical recovery. The warm-white LED light source closely mimics natural daylight, enhancing visualization and comfort during procedures.
Key Features:
  • LED Technology: The lamps feature warm-white LED lights that produce minimal IR and zero UV radiation, creating a cooler work environment and preventing tissue damage.
  • Shadowless Optics: Patented optics ensure a shadowless lighting environment, essential for various surgical procedures.
  • Color Rendering: The lamps have an excellent color rendering index, covering the entire visible spectrum, aiding in distinguishing between healthy and pathological tissues.
  • Durability and Efficiency: The LED light source is durable, shock-resistant, and has a long life of 50,000 hours. It is also energy-efficient and free from hazardous substances.
  • Temperature Control: The lamps maintain a low temperature rise in the surgical area, enhancing comfort for both patients and staff.
Technical Specifications:
  • Models: L2770 and L2750 with light head diameters of 700mm and 500mm, respectively.
  • Illumination: Ranges from 110,000 to 160,000 Lux, with adjustable levels from 30% to 100%.
  • Color Temperature: 4300K ± 500K.
  • Power and Efficiency: Input power of 460 VA, with LED power of 160W for L2770 and 80W for L2750.
  • Illumination Depth: ≥500mm at 60% central illumination and ≥800mm at 20% central illuminance.
Design and Safety:
  • Suspension System: Features a patented suspension arm design for stability and ease of positioning.
  • Heat Dissipation: The aluminum alloy shell ensures efficient heat dissipation, extending the LED's life.
  • Safety Features: Independent control of light source groups prevents total system failure, enhancing surgical safety.
Additional Features:
  • Video Integration: Compatible with SD and HD video systems for documentation and live transmission.
  • Environmental Adaptability: The lamps are designed to minimize turbulence in laminar airflow, reducing cross-infection risks.
Specifications:
  • Temperature rise in the surgical area surface is limited to ≤3℃, and in the surgeon's head area to ≤1℃.
  • The L2700 Series Operating Room Lamps are compatible with both SD and HD video camera systems.
  • Video Camera Specifications:
    • CCD sensor: 1/4" for SD, 1/3" CMOS for HD.
    • Signal system: NTSC or PAL for SD, 1080i for HD.
    • Effective pixels: 440,000 for SD, 2,000,000 for HD.
    • Aspect Ratio: 4:3 for SD, 16:9 for HD.
    • S/N ratio: > 50 dB for both.
    • Optical zoom: 43x motorized for SD, 10x motorized for HD.
    • Digital zoom: 16x for SD, 12x for HD.
    • Focal length: f = 3.21-138.5mm for SD, f = 5.1mm-51.0 mm for HD.
    • Minimum working distance: 100 mm for SD, 10 mm (wide) to 800 mm (tele) for HD.
    • Aperture: F1.65 to F3.7 for SD, F1.8 to F2.1 for HD.
    • Antiflicker and Autofocus: Integrated in both.
    • Sensitivity: 1.4 lx (F1.6, 50IRE) for SD, 1.2 lx (F1.8, 50IRE) for HD.
    • Camera location: Center of lighthead in post for sterilizable handle for both.
    • Control box power supply: 100-240 VAC; 50/60 Hz; 50 VA for both.
    • White balance: Auto for both.
    • Video signal outputs: SD: 75 ohm/external BNC plug-composite; HD: Component YPbPr.
    • Serial link interface: RS-485 for both.
Procedures and Recommendations:
  • The L2700 series lamps can be used with SD and HD video systems for documenting surgical procedures, live transmissions, or consultations with external surgeons.
  • The camera system is versatile, available in different versions, and can be integrated with OR systems to deliver high-quality images to TFT monitors.
Contact Information:
  • Oricare Inc., 1900 AM Drive, Quakertown, PA 18951 USA.
  • Tel: +1-215-538-2470, Fax: +1-215-538-2578.
  • Website: www.oricaremed.com
See more

Catalog excerpts

L2700 Series Operating Room Lamps-1

Your healthcare, we care. L2700 Series Operating Room Lamps Oricare Inc. 1900 AM Drive Quakertown, PA 18951 USA Ll9002 August 2012

 Open the catalog to page 1
L2700 Series Operating Room Lamps-2

Warm-white LED lighting produces low IR and zero UV radiation Oricare L2700 Operating Room Lamps have low Infrared and UV-free radiation, thanks to the warm-white LED light source. This can prevent the desiccation of exposed tissue and prolong tissue life, which can result in accelerated post-surgerical wound recovery. Additionally, it creates a cooler work environment for you and your staff The design of the Oricare L2700 Operating Room Lamps is based on the leading LED technology. optics create bright light which forms an absolutely shadowless lighting environment and meets the requirements...

 Open the catalog to page 2
L2700 Series Operating Room Lamps-3

Warm-white LED lighting produces low IR and zero UV radiation Oricare L2700 Operating Room Lamps have low Infrared and UV-free radiation, thanks to the warm-white LED light source. This can prevent the desiccation of exposed tissue and prolong tissue life, which can result in accelerated post-surgerical wound recovery. Additionally, it creates a cooler work environment for you and your staff The design of the Oricare L2700 Operating Room Lamps is based on the leading LED technology. optics create bright light which forms an absolutely shadowless lighting environment and meets the requirements...

 Open the catalog to page 3
L2700 Series Operating Room Lamps-4

The lamp head is composed of multiple groups of individual light sources, which are controlled separately. Patented light path design, no need for manual focus adjustment Oricare L2700 Series Operating Room Lamps include patented light path focus technology which provides an abundant and uniform lighting field. A 225mm light cylinder diameter and 500mm of light depth provide an effective illuminating solution for most surgery situations, including surgery of a large wound area. Failure of an individual light source group will not cause the whole light to malfunction because each group is controlled...

 Open the catalog to page 4
L2700 Series Operating Room Lamps-5

The lamp head is composed of multiple groups of individual light sources, which are controlled separately. Patented light path design, no need for manual focus adjustment Oricare L2700 Series Operating Room Lamps include patented light path focus technology which provides an abundant and uniform lighting field. A 225mm light cylinder diameter and 500mm of light depth provide an effective illuminating solution for most surgery situations, including surgery of a large wound area. Failure of an individual light source group will not cause the whole light to malfunction because each group is controlled...

 Open the catalog to page 5
L2700 Series Operating Room Lamps-6

Ultra-thin with a streamlined appearance Benefiting from LED light technology, Oricare L2700 Series Operating Lamps do not require the massive reflection body and related complex heat-insulation system of traditional Halogen light systems. Slim and compact, with low wind resistance and a flow-optimized appearance, Oricare L2700 minimizes turbulence in laminar air flow. Therefore, the laminar flow can reach the surgical wound area consistently, avoiding possible cross-infection. Light screen is anti-infrared and scratch-proof. The transparent light screen of Oricare L2700 Operating Room Lamps...

 Open the catalog to page 6
L2700 Series Operating Room Lamps-7

Ultra-thin with a streamlined appearance Benefiting from LED light technology, Oricare L2700 Series Operating Lamps do not require the massive reflection body and related complex heat-insulation system of traditional Halogen light systems. Slim and compact, with low wind resistance and a flow-optimized appearance, Oricare L2700 minimizes turbulence in laminar air flow. Therefore, the laminar flow can reach the surgical wound area consistently, avoiding possible cross-infection. Light screen is anti-infrared and scratch-proof. The transparent light screen of Oricare L2700 Operating Room Lamps...

 Open the catalog to page 7
L2700 Series Operating Room Lamps-8

Patented suspension arm design gives the Oricare L2700 Operating Room Lamps excellent stability with a compact and streamlined appearance Diameter of Light Head Illu minatio n(Lux) Color temp(K) Color Rendering Index (Ra, %) Diameter of light spot (D50, mm) Input Power(VA) Illumination Depth (mm) (20%of Central Illuminance) interactive control system and patented drift - proof technology assure that the light head is fully cardanic and extremely stable. Short ceiling axis is compatible with low-rise operating rooms. The central sterile handle allows the surgeon to control the light head position...

 Open the catalog to page 8
L2700 Series Operating Room Lamps-9

Oricare L2700 series Operating Room Lamps can be easily used in conjunction with our SD and HD video systems, if you wish to document surgical procedures for training purposes, make use of live transmissions or consult with external surgeons during operations. The camera system is available in different versions and can be operated with integrated OR systems. It delivers first-rate images in SD or HD quality straight to the TFT monitor. Technical Data Video Camera Signal system Effective number of pixels Horizontal resolution (at center) (LVT) -Standard NTSC or PAL Aspect Ratio Optical zoom Digital...

 Open the catalog to page 9
L2700 Series Operating Room Lamps-10

Patented suspension arm design gives the Oricare L2700 Operating Room Lamps excellent stability with a compact and streamlined appearance Diameter of Light Head Illu minatio n(Lux) Color temp(K) Color Rendering Index (Ra, %) Diameter of light spot (D50, mm) Input Power(VA) Illumination Depth (mm) (20%of Central Illuminance) interactive control system and patented drift - proof technology assure that the light head is fully cardanic and extremely stable. Short ceiling axis is compatible with low-rise operating rooms. The central sterile handle allows the surgeon to control the light head position...

 Open the catalog to page 10
L2700 Series Operating Room Lamps-11

Oricare L2700 series Operating Room Lamps can be easily used in conjunction with our SD and HD video systems, if you wish to document surgical procedures for training purposes, make use of live transmissions or consult with external surgeons during operations. The camera system is available in different versions and can be operated with integrated OR systems. It delivers first-rate images in SD or HD quality straight to the TFT monitor. Technical Data Video Camera Signal system Effective number of pixels Horizontal resolution (at center) (LVT) -Standard NTSC or PAL Aspect Ratio Optical zoom Digital...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.