M7600/M7400 - 1

M7600/M7400 patient monitor Technical Specifications Your healthcare, we care. Calculations • Medications • Hemodynamics • Respiratory Mechanics • Oxygenation • Renal Clearance • Fick Output • Heart Rate Variability (HRV): Time Domain Histogram Default Alarms • User defined • Fixed or calculated values • Alarm levels: Clinical levels: C1, C2, C3, C4 Technical levels: T1, T2 • Visual and Audible alarm Recorder (Optional) • Integrated Recorder up to 3 channels Analog Output M7600 (M7400 optional) • ECG II- 1Volt/mV • ECG V1 - 1Volt/mV • QRS - 5 Volt • ART - 1Volt/100 mmHg • Output to input delay < 20 ms Languages • English, Dutch, French, Italian, Spanish, Espanol, Portuguese, Turkish, Russian, Polish. Regulatory Approvals • EN 60601-1 • EN 60601-1-1 • EN 60601-1-2 • Degree of protection against electrical chock ECG / RSP, ISP, CO and TEMP = Type CF NIBP, SpO2 and EtCO2 = Type BF • CE Mark 0473 • FDA Clearance - K073140, K093766 • WIFI FCC ID XM5-SM2144N1/2 • Industrial Canada 8514A- SMC 2144N ½ ECG(3/5/l0 Lead) • Leads: ECG cables for 3/5/10-lead surface ECG with defibrillation protection in the cable • Input Dynamic Range: ±5 mV peak to peak • Input DC Offset: ±530 mV • Baseline Correction: Automatic recovery of waveform within 100 ms • Notch Filtering: 50Hz or 60Hz • Frequency Response: - Diagnostic 0.05 to 150Hz - Monitoring 0.5 to 40Hz - ST 0.05 to 40Hz - Exercise 1 to 25Hz • Sensitivity: 0.25, 0.5, 1.0, 2.0, 4.0, 8.0 mV/cm (nominal) • Common Mode Rejection: 120 dB minimum • Noise: 30 microvolts • Input Impedance: 2.5 mega Ω • Defibrillator Pulse Protection: Yes • Baseline Recovery: < 8 sec • Lead Fault Sense: Based on impedance with driven lead • Digital Sample Rate: 640Hz • Sample Resolution: 24 bit • Pacemaker Detection and Rejection of Pacer Artifact • Pacer Detection Flag inserted into ECG waveform • 3 Detection Modes: - Fixed Threshold 2mV - Adaptive 1 Threshold 1/2mV High Sensitivity - Adaptive 2 Threshold > 2mV High Immunity • Auto Cable Detection • Audio Indicator: QRS Beep—Adjustable volume • QRS Detection Range: - Height: 0.25 or 0.15 mV to 5.0 millivolt - Width: 70 to 120 milliseconds • Heart Rate Counting: - Range: 0 to 350 BPM - 0-300 Accuracy: ±2 BPM, 300-350 Accuracy ±4 BPM • Note: Values below 20- forced to zero • Heart Rate Alarm Settings • High and low rate: 20 - 350 BPM non-overlapping • Leads analyzed for Heart Rate and Arrhythmia Configuration: Top two displayed • ECG Leads: - I, II, III (3 Lead cable) - I, II, III, aVR, aVL, aVF, V (5 Lead cable) - I, II, III, aVR, aVL, aVF, V1-V6 (12 Lead module) ST on all leads: - Automatic or Manual - ST range +8 mm to -8 mm - ST Alarm Arrhythmia: Detection and alarm on 19 Arrhythmias PR and QT measurement and display Data Storage: Beat notification, RR Interval, Heart Rate, ST values, Arrhythmia, Alarms, Alarm event markers Respiration • Leads: RA -LA or Leads: RA -LL • Excitation: 65 kHz, < 1 mA • Frequency Response: 0.13 to 2.5Hz • Impedance Range: 100 to 3000 Ω • Input Sensitivity Range: 0.2 to 5 Ω • Digital Sample Rate: 640 Hz • Sample Resolution: 24 bit • Sweep Speed: ECG speed, 6.25, 12.5 mm/sec (nominal) • Gain: Automatic or 1/8 to x 8 • Respiration Rate Counting Range: 0 to 150 breaths/min • Respiration rate: Accuracy +/- 1 per minute • Respiration Alarm Settings - Low rate: 0 - 150 BPM - High rate: 0 - 150 BPM - Apnea: User configurable (10, 15, 20, 30, 45, 60, 90 Sec.) - Cardiac coincidence alarm • Data Storage: Respiration rate, Respiration rate Alarms, Apnea alarms, Alarm event markers Invasive Blood Pressure • Site Labels: BPx, ART, PAP, CVP, RAP, LAP, ICP • Input Sensitivity: 5μVolt/Volt/mmHg • IBP waveform synchronized to ECG • Dynamic Range - Pressure range: -50 to +350 mmHg - Zero range: ±150 mmHg - Total dynamic range: -200 to +450 mmHg - Heart rate: 20 - 350 BPM • Transducer Excitation Voltage: +5 VDC Separate excitation driver for each channel • Zero Accuracy: ±0.2 mmHg • Zero Drift: Less than ±0.2 mmHg in 24 hours (at constant temperature) • Blood Pressure Accuracy: ±2 mmHg or ±2%, whichever is greater, exclusive of transducer • Blond Pressure Linearity: within 1% across entire range • Waveform Frequency Response: 0 - 40 Hz • Sampling Rate: 640 Hz • Sample Resolution: 24 bit • Fault Detection: Transducer in/out, Cable out • Data Storage: Systolic, Diastolic and Mean; Alarms Pulse Oximetry (SpO 2 ) • Nellcor® Oximax or Masimo® SET Technology • Plethysmograph waveform • Saturation Range: 1% to 100% SpO 2 • Extreme Alarm Capability • SpO 2 Accuracy: SpO 2 % +/-3 digits standard deviation • Pulse Rate Range: 20 to 250 BPM +/-3 BPM • Saturation alarm limits: 0% to 100% • Data Storage: Heart rate end O 2 saturation, Alarms Thermo Dilution Cardiac Output • Adapter and Compatibility Cables: - CO Set interface cable - Ice Bath YSI-400 cardiac output interface cable - Dual temperature interface cable (YSI-400) • Temperature Range - Blood temperature: 27°C to 45°C (81°F to 113°F) - Injectate temperature: 0°C to 25°C (32°F to 77°F) -Body temperature: 0°C to 45°C (32°F to 113°F) • Accuracy ±0.1°C over the entire range • Digital Sample Rate: 160 Hz • Sample Resolution: 24 bit • Frequency Response: 0 to 15 Hz • Cardiac Output Determination Range: 0 to 20 liters per minute • Injectate Volumes: 1, 3, 5, and 10cc • Displayed Data: Cardiac Output, Cardiac Index, Stroke Volume, Stroke Volume Index, Blood Temperature, Injectate Temperature, Trial Number • Data Storage: -In Cardiac Output mode: Cardiac Output, Hemodynamic Calculation results -Measuring time -In Two Temp mode: Temperatures and Delta-Temp. Temperature Alarms Non-Invasive Blood Pressure • Oscillometric Method • Displayed Parameters: Systolic, Diastolic, Mean pressure values, Time of last measurement, and next measurement • Cuff Size: Adult, Pediatric, Infant, Neonatal • Inflation Rate: Within 5 sec. • Initial inflation target: 150 mmHg, Adult/Pediatric • Initial inflation target: 100 mmHg, Neonatal • Over pressure limit: 290 mmHg, Adult/Pediatric • Over pressure limit: 145 mmHg, Neonatal • Cycle Times Deflation time (typical): 30 sec.; BP time-out: 60 - 180 sec. • Measurement Ranges, Adult (in mmHg) Systolic: 30 to 255; Diastolic: 15 to 220; Mean: 20 to 235 • Measurement Ranges, Neonatal (in mmHg) Systolic: 30 to 135; Diastolic: 15 to 110; Mean: 20-125 • Pressure: Transducer Accuracy ±3 mmHg or ±2%, whichever is greater • Heart Rate: -Adult/Pediatric: 30 to 240 BPM -Neonatal: 40 to 240 BPM • Modes: Auto, Manual, STAT • Automatic intervals 1, 2, 3, 4, 5, 10, 15, 20, 30, 60, 120, 180, 240, 360, 480 minutes • Data Storage: Measurement time markers, S/D/M, Alarm event markers Temperature • YSI 400 Series Probes • Body temperature: 0°C to 45°C (32°F to 113°F) +/- 0.1°C • Temperature Alarm Range: 25°C to 45°C (77°F to 113°F) • Data storage: Temperature and Delta temperature, Temperature alarms Delta Temperature • Range +/ - 45°C • Delta temp Accuracy: +/- 0.1°C End Tidal CO 2 Microstream (EtCO 2 ) • Sidestream method • Flow rate: 50 mL/min (accuracy: -7.5 mL/min + 15 mL/min) • Displayed Data: -Waveform labels and annotations -EtCO 2 , insp CO 2 and respiration rate values • CO 2 Display Range: 0-99 mmHg • Measurement Resolution: Typical Accuracy ±2 mmHg for CO 2 range of 0-38 mmHg +0.08% for every 1 mmHg above 38 mmHg ±5% for CO 2 range of 39-99 mmHg • Respiration Rate: -0 to 70 bpm: ±1 bpm -71 to 120 bpm: ±2 bpm -121 to 150 bpm: ±3 bpm • Rise Time: 190 msec (10% - 90%) • Delay Time: 2.7 sec (10% - 90%) typical • Start-up Time: 30 sec typical • Automatic Compensation: At least once per hour • Ambient Temperature: 0-65°C • Humidity: 10-95%, non-condensing • Barometric Pressure: 430-795 mmHg (-1250 to 15,000 ft; -380 to 5200 meter) • Calibration required: Initially - after 1200 operating hours and then once a year or 4000 operating hours • CO 2 Alarm Limits: 0 to 100 mmHg; 0 to 10%; 0 to 15 kPa • Respiration Rate Alarm Limits: Neonatal - 0 to 150 BMP; Adult - 0 to 50 BPM • Data Storage: EtCO 2 , insp CO 2 and Respiration Rate values, Alarms, Apnea, Alarm • Exhaust Gas Outlet BIS Interface BISx Technology • Bispectral Index (BIS): 0 to 100 (0 = no brain activity, 100 = fully conscious) • Electromyographic Strength (EMG): 25 to 100 dB (where 1 microvolt = 40dB) • Signal Quality Index (SQI): 0 to l00% • Suppression Ratio (SR): 0 to 100% • Spectral Edge Frequency (SEF): 0.5 to 30.0 Hz • Total Power (TP): 40 to 100 dB((1 microvolt)2 rms = 40dB) • Burst Count (BC): 0 to 30 (with an Extend Sensor only) • BEG: Two channel, real-time EEG waveform • Noise (EEG Waveform) < 0.3 microvolt RMS (2.0 microvolts peak-to-peak) • BIS Numeric Update Frequency: Once per second • Band width: 0.25 to 100 Hz (- 3dB) • Filters: -High Pass: 0.25, 1, 2 Hz -Low Pass: 30, 50, 70 Hz -Notch: 50 or 60 Hz • Impedance Measurement Range: 0 to 999 kOhm • Data Storage: -Numeric Chart -Graphic Trend -BEG waveform full disclosure -CRG trend • Display features: -EEG waveforms -EEG waveform + Trend of BIS and EMG -BIS value and alarm limit -EMG and SQl at vertical bars -SR, BC, TP numeric display • Alarms: -High BIS alarm: 0 - 100 -Low BIS alarm: 0 - 100 Anesthetic Gases Module • Agent Gas External Module with Automatic 5 Agent Identification • Size: (WxDxH) 145x350x90 mm / 5.75x13.75x3.5 in • Weight 3.85 kg / 8.5 lbs • Power: Input Voltage 100 to 240 Vac - 48 to 62 Hz • Sampling Gas Flow Rate: 120 mL/ min • Environment: -Temperature: +10 to +40°C / +50 to 104°F -Humidity: 10 to 95% RH (non-condensing) -Barometric Pressure / Altitude: 525mmHg to 790mmHg / -305 m to + 3,048 m M7600 Patient Monitoring System M7400 Patient Monitoring System Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA GL9001 October 2012

Open the catalog to page 1

All Oricare catalogs and technical brochures

  1. L2700 Series

    6 Pages

  2. T3600

    16 Pages

  3. P1000 Series

    12 Pages

  4. V8800

    6 Pages

  5. A9800

    6 Pages

  6. M7800

    6 Pages

Archived catalogs