M7600/M7400 patient monitor Technical Specifications Your healthcare, we care. Calculations • Medications • Hemodynamics • Respiratory Mechanics • Oxygenation • Renal Clearance • Fick Output • Heart Rate Variability (HRV): Time Domain Histogram Default Alarms • User defined • Fixed or calculated values • Alarm levels: Clinical levels: C1, C2, C3, C4 Technical levels: T1, T2 • Visual and Audible alarm Recorder (Optional) • Integrated Recorder up to 3 channels Analog Output M7600 (M7400 optional) • ECG II- 1Volt/mV • ECG V1 - 1Volt/mV • QRS - 5 Volt • ART - 1Volt/100 mmHg • Output to input delay < 20 ms Languages • English, Dutch, French, Italian, Spanish, Espanol, Portuguese, Turkish, Russian, Polish. Regulatory Approvals • EN 60601-1 • EN 60601-1-1 • EN 60601-1-2 • Degree of protection against electrical chock ECG / RSP, ISP, CO and TEMP = Type CF NIBP, SpO2 and EtCO2 = Type BF • CE Mark 0473 • FDA Clearance - K073140, K093766 • WIFI FCC ID XM5-SM2144N1/2 • Industrial Canada 8514A- SMC 2144N ½ ECG(3/5/l0 Lead) • Leads: ECG cables for 3/5/10-lead surface ECG with defibrillation protection in the cable • Input Dynamic Range: ±5 mV peak to peak • Input DC Offset: ±530 mV • Baseline Correction: Automatic recovery of waveform within 100 ms • Notch Filtering: 50Hz or 60Hz • Frequency Response: - Diagnostic 0.05 to 150Hz - Monitoring 0.5 to 40Hz - ST 0.05 to 40Hz - Exercise 1 to 25Hz • Sensitivity: 0.25, 0.5, 1.0, 2.0, 4.0, 8.0 mV/cm (nominal) • Common Mode Rejection: 120 dB minimum • Noise: 30 microvolts • Input Impedance: 2.5 mega Ω • Defibrillator Pulse Protection: Yes • Baseline Recovery: < 8 sec • Lead Fault Sense: Based on impedance with driven lead • Digital Sample Rate: 640Hz • Sample Resolution: 24 bit • Pacemaker Detection and Rejection of Pacer Artifact • Pacer Detection Flag inserted into ECG waveform • 3 Detection Modes: - Fixed Threshold 2mV - Adaptive 1 Threshold 1/2mV High Sensitivity - Adaptive 2 Threshold > 2mV High Immunity • Auto Cable Detection • Audio Indicator: QRS Beep—Adjustable volume • QRS Detection Range: - Height: 0.25 or 0.15 mV to 5.0 millivolt - Width: 70 to 120 milliseconds • Heart Rate Counting: - Range: 0 to 350 BPM - 0-300 Accuracy: ±2 BPM, 300-350 Accuracy ±4 BPM • Note: Values below 20- forced to zero • Heart Rate Alarm Settings • High and low rate: 20 - 350 BPM non-overlapping • Leads analyzed for Heart Rate and Arrhythmia Configuration: Top two displayed • ECG Leads: - I, II, III (3 Lead cable) - I, II, III, aVR, aVL, aVF, V (5 Lead cable) - I, II, III, aVR, aVL, aVF, V1-V6 (12 Lead module) ST on all leads: - Automatic or Manual - ST range +8 mm to -8 mm - ST Alarm Arrhythmia: Detection and alarm on 19 Arrhythmias PR and QT measurement and display Data Storage: Beat notification, RR Interval, Heart Rate, ST values, Arrhythmia, Alarms, Alarm event markers Respiration • Leads: RA -LA or Leads: RA -LL • Excitation: 65 kHz, < 1 mA • Frequency Response: 0.13 to 2.5Hz • Impedance Range: 100 to 3000 Ω • Input Sensitivity Range: 0.2 to 5 Ω • Digital Sample Rate: 640 Hz • Sample Resolution: 24 bit • Sweep Speed: ECG speed, 6.25, 12.5 mm/sec (nominal) • Gain: Automatic or 1/8 to x 8 • Respiration Rate Counting Range: 0 to 150 breaths/min • Respiration rate: Accuracy +/- 1 per minute • Respiration Alarm Settings - Low rate: 0 - 150 BPM - High rate: 0 - 150 BPM - Apnea: User configurable (10, 15, 20, 30, 45, 60, 90 Sec.) - Cardiac coincidence alarm • Data Storage: Respiration rate, Respiration rate Alarms, Apnea alarms, Alarm event markers Invasive Blood Pressure • Site Labels: BPx, ART, PAP, CVP, RAP, LAP, ICP • Input Sensitivity: 5μVolt/Volt/mmHg • IBP waveform synchronized to ECG • Dynamic Range - Pressure range: -50 to +350 mmHg - Zero range: ±150 mmHg - Total dynamic range: -200 to +450 mmHg - Heart rate: 20 - 350 BPM • Transducer Excitation Voltage: +5 VDC Separate excitation driver for each channel • Zero Accuracy: ±0.2 mmHg • Zero Drift: Less than ±0.2 mmHg in 24 hours (at constant temperature) • Blood Pressure Accuracy: ±2 mmHg or ±2%, whichever is greater, exclusive of transducer • Blond Pressure Linearity: within 1% across entire range • Waveform Frequency Response: 0 - 40 Hz • Sampling Rate: 640 Hz • Sample Resolution: 24 bit • Fault Detection: Transducer in/out, Cable out • Data Storage: Systolic, Diastolic and Mean; Alarms Pulse Oximetry (SpO 2 ) • Nellcor® Oximax or Masimo® SET Technology • Plethysmograph waveform • Saturation Range: 1% to 100% SpO 2 • Extreme Alarm Capability • SpO 2 Accuracy: SpO 2 % +/-3 digits standard deviation • Pulse Rate Range: 20 to 250 BPM +/-3 BPM • Saturation alarm limits: 0% to 100% • Data Storage: Heart rate end O 2 saturation, Alarms Thermo Dilution Cardiac Output • Adapter and Compatibility Cables: - CO Set interface cable - Ice Bath YSI-400 cardiac output interface cable - Dual temperature interface cable (YSI-400) • Temperature Range - Blood temperature: 27°C to 45°C (81°F to 113°F) - Injectate temperature: 0°C to 25°C (32°F to 77°F) -Body temperature: 0°C to 45°C (32°F to 113°F) • Accuracy ±0.1°C over the entire range • Digital Sample Rate: 160 Hz • Sample Resolution: 24 bit • Frequency Response: 0 to 15 Hz • Cardiac Output Determination Range: 0 to 20 liters per minute • Injectate Volumes: 1, 3, 5, and 10cc • Displayed Data: Cardiac Output, Cardiac Index, Stroke Volume, Stroke Volume Index, Blood Temperature, Injectate Temperature, Trial Number • Data Storage: -In Cardiac Output mode: Cardiac Output, Hemodynamic Calculation results -Measuring time -In Two Temp mode: Temperatures and Delta-Temp. Temperature Alarms Non-Invasive Blood Pressure • Oscillometric Method • Displayed Parameters: Systolic, Diastolic, Mean pressure values, Time of last measurement, and next measurement • Cuff Size: Adult, Pediatric, Infant, Neonatal • Inflation Rate: Within 5 sec. • Initial inflation target: 150 mmHg, Adult/Pediatric • Initial inflation target: 100 mmHg, Neonatal • Over pressure limit: 290 mmHg, Adult/Pediatric • Over pressure limit: 145 mmHg, Neonatal • Cycle Times Deflation time (typical): 30 sec.; BP time-out: 60 - 180 sec. • Measurement Ranges, Adult (in mmHg) Systolic: 30 to 255; Diastolic: 15 to 220; Mean: 20 to 235 • Measurement Ranges, Neonatal (in mmHg) Systolic: 30 to 135; Diastolic: 15 to 110; Mean: 20-125 • Pressure: Transducer Accuracy ±3 mmHg or ±2%, whichever is greater • Heart Rate: -Adult/Pediatric: 30 to 240 BPM -Neonatal: 40 to 240 BPM • Modes: Auto, Manual, STAT • Automatic intervals 1, 2, 3, 4, 5, 10, 15, 20, 30, 60, 120, 180, 240, 360, 480 minutes • Data Storage: Measurement time markers, S/D/M, Alarm event markers Temperature • YSI 400 Series Probes • Body temperature: 0°C to 45°C (32°F to 113°F) +/- 0.1°C • Temperature Alarm Range: 25°C to 45°C (77°F to 113°F) • Data storage: Temperature and Delta temperature, Temperature alarms Delta Temperature • Range +/ - 45°C • Delta temp Accuracy: +/- 0.1°C End Tidal CO 2 Microstream (EtCO 2 ) • Sidestream method • Flow rate: 50 mL/min (accuracy: -7.5 mL/min + 15 mL/min) • Displayed Data: -Waveform labels and annotations -EtCO 2 , insp CO 2 and respiration rate values • CO 2 Display Range: 0-99 mmHg • Measurement Resolution: Typical Accuracy ±2 mmHg for CO 2 range of 0-38 mmHg +0.08% for every 1 mmHg above 38 mmHg ±5% for CO 2 range of 39-99 mmHg • Respiration Rate: -0 to 70 bpm: ±1 bpm -71 to 120 bpm: ±2 bpm -121 to 150 bpm: ±3 bpm • Rise Time: 190 msec (10% - 90%) • Delay Time: 2.7 sec (10% - 90%) typical • Start-up Time: 30 sec typical • Automatic Compensation: At least once per hour • Ambient Temperature: 0-65°C • Humidity: 10-95%, non-condensing • Barometric Pressure: 430-795 mmHg (-1250 to 15,000 ft; -380 to 5200 meter) • Calibration required: Initially - after 1200 operating hours and then once a year or 4000 operating hours • CO 2 Alarm Limits: 0 to 100 mmHg; 0 to 10%; 0 to 15 kPa • Respiration Rate Alarm Limits: Neonatal - 0 to 150 BMP; Adult - 0 to 50 BPM • Data Storage: EtCO 2 , insp CO 2 and Respiration Rate values, Alarms, Apnea, Alarm • Exhaust Gas Outlet BIS Interface BISx Technology • Bispectral Index (BIS): 0 to 100 (0 = no brain activity, 100 = fully conscious) • Electromyographic Strength (EMG): 25 to 100 dB (where 1 microvolt = 40dB) • Signal Quality Index (SQI): 0 to l00% • Suppression Ratio (SR): 0 to 100% • Spectral Edge Frequency (SEF): 0.5 to 30.0 Hz • Total Power (TP): 40 to 100 dB((1 microvolt)2 rms = 40dB) • Burst Count (BC): 0 to 30 (with an Extend Sensor only) • BEG: Two channel, real-time EEG waveform • Noise (EEG Waveform) < 0.3 microvolt RMS (2.0 microvolts peak-to-peak) • BIS Numeric Update Frequency: Once per second • Band width: 0.25 to 100 Hz (- 3dB) • Filters: -High Pass: 0.25, 1, 2 Hz -Low Pass: 30, 50, 70 Hz -Notch: 50 or 60 Hz • Impedance Measurement Range: 0 to 999 kOhm • Data Storage: -Numeric Chart -Graphic Trend -BEG waveform full disclosure -CRG trend • Display features: -EEG waveforms -EEG waveform + Trend of BIS and EMG -BIS value and alarm limit -EMG and SQl at vertical bars -SR, BC, TP numeric display • Alarms: -High BIS alarm: 0 - 100 -Low BIS alarm: 0 - 100 Anesthetic Gases Module • Agent Gas External Module with Automatic 5 Agent Identification • Size: (WxDxH) 145x350x90 mm / 5.75x13.75x3.5 in • Weight 3.85 kg / 8.5 lbs • Power: Input Voltage 100 to 240 Vac - 48 to 62 Hz • Sampling Gas Flow Rate: 120 mL/ min • Environment: -Temperature: +10 to +40°C / +50 to 104°F -Humidity: 10 to 95% RH (non-condensing) -Barometric Pressure / Altitude: 525mmHg to 790mmHg / -305 m to + 3,048 m M7600 Patient Monitoring System M7400 Patient Monitoring System Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA GL9001 October 2012
Open the catalog to page 1All Oricare catalogs and technical brochures
-
V8600 Ventilator
6 Pages
-
L2700 Series
6 Pages
-
T3600
16 Pages
-
T3600 Operating Table
8 Pages
-
P1000 Series
12 Pages
-
Anesthetic A9040 Vaporizer
2 Pages
-
A9600 Anesthesia Workstation
6 Pages
-
C4500 Medical Air Compressor
2 Pages
-
V8800
6 Pages
-
A9800
6 Pages
-
M7800
6 Pages
-
V8800 Ventilator System
2 Pages
Archived catalogs
-
T3600 Operating Table
6 Pages
-
A9600 Anesthesia Workstation
2 Pages