Catalog excerpts

ECG(3/5/l0 Lead) • LED for function indication • Leads: ECG cables for 3 / 5 / 10-leads with integrated defibrillation protection • Input Dynamic Range: ±5 mV peak to peak • Input DC Offset: ±300 mV • Baseline Correction: Automatic recovery of waveform within 100 msec • Notch Filtering: 50Hz or 60Hz • Frequency Response: -Diagnostic 0.05 to 150Hz -Monitoring 0.5 to 40Hz -ST 0.05 to 40Hz -Exercise 1 to 25Hz • Sensitivity: 0.25, 0.5, 1.0, 2.0, 4.0, 8.0 mV/cm • Common Mode Rejection: 120 dB minimum • Noise: 30μV • Input Impedance: > 2.5 mega Ω • Defibrillator Pulse Protection: Yes • Baseline Recovery: < 8 sec • Lead Fault Sense: Based on impedance with driven lead • Digital Sample Rate: 640Hz • Sample Resolution: 22 bit • Pacemaker Detection and Rejection of Pacer Artifact. • Pacer Detection Flag inserted into ECG waveform. -3 Detection Modes: 1.Fixed Threshold 2mV 2.Adaptive 1 Threshold 1/2mV High Sensitivity 3.Adaptive 2 Threshold > 2mV High Immunity • Auto Cable Type ( 3 / 5 / 10) Detection • Audio Indicator: QRS Beep - Adjustable volume • QRS Detection Range: -Height: 0.25 to 5.0 millivolt or 0.15mv -Width: 70 to 120 milliseconds • Heart Rate Counting: -Range: 0 to 350 BPM -0-300 Accuracy: ±2 BPM, 300-350 Accuracy ±4 BPM • Leads analyzed for Heart Rate and Arrhythmia Configuration: -Top two displayed ECG leads • ECG Leads: -I, II, III (3 Lead cable) -I, II, III, aVR, aVL, aVF, V (5 Lead cable) -I, II, III, aVR, aVL, aVF, V1-V6 (12 Lead module) • ST on all leads -Automatic or Manual -ST Range + 8 mm to -8 mm -ST Alarm • Arrhythmia: Detection and alarm on 19 Arrhythmias • PR and QT measurement and display • Data Storage: Beat notification, RR Interval, Heart Rate, ST values, Arrhythmia Alarms, Parameter settings, Cycle Time and Measurement Time Markers, Alarm Event Markers Respiration • Leads: RA -LA or Leads: RA -LL • Excitation: 65 kHz, < 1 mA • Frequency Response: 0.13 to 2.5Hz • Impedance Range: 100 to 3000 Ω • Input Sensitivity Range: 0.2 to 5 Ω • Digital Sample Rate: 640 Hz • Sample Resolution: 22 bit • Sweep Speed: ECG speed, 6.25, 12.5 mm/Sec • Gain: Automatic or 1/8 to x 8 • Respiration Rate Counting Range: 0 to 150 breaths/min • Respiration Alarm Settings -Low rate: 0 - 150 BPM -High rate: 0 - 150 BPM -Apnea: User configurable -Cardiac coincidence alarm • Data Storage: -Respiration rate -Respiration rate alarms -Apnea alarms (10, 15, 20, 30, 45, 60, 90 Sec) -Alarm event markers Invasive Blood Pressure • LED for function indication • Site Labels: BPx, ART, PAP, CVP, RAP, LAP, ICP • Input Sensitivity: 5 MicroVolt / Volt / mmHg • Dynamic Range -Pressure range: -50 to +350 mmHg -Zero range: ±150 mmHg -Total dynamic range: -200 to +450 mmHg -Heart rate: 20 - 350 BPM • Transducer Excitation Voltage: +5 VDC -Separate excitation driver for each channel • Zero Accuracy: ±0.2 mmHg • Zero Drift: Less than ±0.2 mmHg in 24 hours, (at constant temperature) • Blood Pressure Accuracy: ±2 mmHg or ±2%, whichever is greater, exclusive of transducer Blood Pressure Linearity: within 1% across entire range Waveform Frequency Response: 0 - 40 Hz Fault Detection: Transducer in/out, Cable out Data Storage: Systolic, Diastolic and Mean; Alarms Pulse Oximetry (SpO 2 ) • LED for function indication • Nellcor® Oximax or Masimo® SET Technology • Saturation Range: 1% to 100% SpO 2 • SpO 2 Accuracy: SpO 2 % ±1% standard deviation • Pulse Rate Range: 20 to 250 BPM ± 3 BPM • Saturation alarm limits: 0% to 100% • Data Storage: Heart rate end O 2 saturation, Alarms Thermo Dilution Cardiac Output • LED for function indication • Adapter and Compatibility Cables: -CO Set interface cable -Ice Bath YSI-400 cardiac output interface cable -Dual temperature interface cable (YSI-400) • Temperature Range -Blood temperature: 27°C to 45°C (81°F to 113°F) -Injectate temperature: 0°C to 25°C (32°F to 77°F) -Body temperature: 0°C to 45°C (32°F to 113°F) • Accuracy ±0.1 over the entire range • Cardiac Output Determination Range: 0 to 20 liters per minute • Injectate Volumes: 1, 3, 5, and 10cc • Displayed Data: Cardiac Output, Cardiac Index, Stroke Volume, Stroke Volume Index, Blood Temperature, Injectate Temperature, Trial Number • Data Storage: In Cardiac Output mode: - Cardiac output - Hemodynamic Calculation result - Measuring time In Two Temp mode: - Temperatures and Delta-Temp - Temperature Alarm Non-Invasive Blood Pressure • LED for function indication • Oscillometric Method • Displayed Parameters: Systolic, Diastolic, Mean pressure values, Time of last measurement, and next measurement • Cuff Size: Adult, Pediatric, Infant, Neonatal • Inflation Rate: Within 5 sec. -Initial inflation target: 150 mmHg, Adult/Pediatric -Initial inflation target: 100 mmHg, Neonatal • Cycle Times -Deflation time (typical): 30 sec.; BP time-out: 60 - 180 sec. • Measurement Ranges, Adult (in mmHg) -Systolic: 30 to 255; Diastolic: 15 to 220; Mean: 20 to 235 • Measurement Ranges, Neonatal (in mmHg) -Systolic: 30 to 135; Diastolic: 15 to 110; Mean: 20-125 • Pressure: Transducer Accuracy ±3 mmHg or ±2%, whichever is greater • Heart Rate: -Adult/Pediatric: 30 to 240 BPM -Neonatal: 40 to 240 BPM • Modes: Auto, Manual, STAT • Automatic intervals 1, 2, 3, 4, 5, 10, 15, 20, 30, 60,120, 180, 240, 360, 480 minutes • Data Storage: Measurement time markers, S/D/M, Alarm event markers Temperature • YSI 400 Series Probes • Body temperature: 0°C to 45°C (32°F to 113°F) • Temperature Alarm Range: 25°C to 45°C (77°F to 113°F) • Data storage: Temperature and Delta temperature, Temperature alarms End Tidal CO 2 Microstream (EtCO 2 ) • LED for function indication • Sidestream method • Flow rate: 50mI /min (accuracy: -7.5ml/min + 15ml/min) • Displayed Data: -Waveform labels and annotations -EtCO 2 , insp CO 2 and respiration rate values •CO 2 Display Range: 0-99 mmHg •Measurement Resolution: Typical Accuracy -±2 mmHg for CO 2 range of 0-38 mmHg -±5% for CO 2 range of 39-99 mmHg -+0.08% for every 1 mmHg above 38 mmHg •Respiration Rate: -0 to 70 bpm: ±1 bpm -71 to 120 bpm: ±2 bpm -121 to 150 bpm: ±3 bpm •Rise Time: 190 msec (10% - 90%) •Delay Time: 2.7 Sec (10% - 90%) typical •Start-up Time: 30 sec typical Automatic Compensation: At least once per hour Ambient Temperature: 0-65°C Humidity: 10-95% RH, non-condensing Barometric Pressure: 430-795 mmHg (-1250 to 15,000 ft; -380 to 5200 meter) Calibration required: Initially - after 1200 operating hours and then once a year or 4000 operating hours CO 2 Alarm Limits: 0 to 100 mmHg; 0 to 10%; 0 to 15 kPa Respiration Rate Alarm Limits -Neonatal : 0 to 150 BPM -Adult: 0 to 50 BPM Data Storage: EtCO 2 , insp CO 2 and Respiration Rate values, Alarms, Apnea Alarm EEG – 4 Channel • LED for function indication • Uses 5 electrodes • Four differential channels • Gain options: 10, 20, 50, 70, 100, 200 microvolts/cm; Default 70 microvolts/cm • Filters -Lower filter (High pass): 0.5, 1.5 -Upper filter (Low PASS): 15, 35, 50, 70 • Input Specifications: -DC input offset voltage is up to ±300 mV -Input Dynamic Range up to ±5 mV -Common mode rejection (CMRR) - 120 db -Maximum DC input current is 100nA -Input Impedance, typical: 0.5 M Ω -System noise, referenced to input (RTI), is 3 microvolts p-p • Multi-channel crosstalk is less than 2% • Defibrillator Pulse Protection: Yes • Data Storage: -Waveforms 4 channels Spirometry Module • LED for function indication • For use for patients with tidal volumes greater than 100 ml. • Waveforms: -Air Flow -Air Volume -Airway pressure • Loops: -Flow Volume -Pressure Volume -Flow Pressure Spirometry Measured Parameters • RR - Respiration Rate • VT - Tidal Volume • MV - Minute Volume • PIP - Peak Inspiration Pressure • MAP - Mean Airway Pressure • PEEP - Positive End Expiratory Pressure • RES - Resistance • COMP - Compliance • PLTP - Plateau Pressure EZ-Flow TM Flow Airway Adapter Specifications • Flow Range: 2 – 180 lpm (33 – 3000 ml/s) • Accuracy: ±5% reading, or 0.5 lpm • Dead Space: 6.9 ml • Flow (L/min): -Range: Adult 2.0 to 180 -Accuracy: Greater of 0.5 LPM or ±3% of reading •Tidal Volume (ml) -Range: Adult 200 to 3000 -Resolution: Adult 1 ml -Volume Accuracy: Greater of ±10 ml or ±3% of reading • Respiration Rate (breaths/min) -Range: Adult 2 to 120 -Accuracy: Adult ±1 • Airway Pressure (cm H 2 O) -Range: Adult -120 to 120 -Resolution: Adult 0.1 cm H 2 O -Accuracy: Adult ±2% of reading BIS Interface BISx Technology • Bispectral Index (BIS): 0 to 100 (0 = no brain activity, 100 = fully conscious) • Electromyographic Strength (EMG): 25 to 100 dB (where 1 microvolt = 40dB) • Signal Quality Index (SQl): 0 to l00% • Suppression Ratio (SR): 0 to 100% • Spectral Edge Frequency (SEF): 0.5 to 30.0 Hz • Total Power (TP): 40 to 100 dB (1microvolt 2 RMS = 40dB) • Burst Count (BC): 0 to 30 (with an Extend Sensor only) • EEG: Two channel, real-time EEG waveform • Noise (EEG Waveform) < 0.3 microvolt RMS (2.0 microvolt peak-to-peak) • BIS Numeric Update Frequency: Once per second • Band width: 0.25 to 100 Hz (- 3dB) • Filters: -High Pass: 0.25, 1, 2 Hz -Low Pass: 30, 50, 70 Hz -Notch: 50 or 60 Hz • Impedance Measurement Range: 0 to 999 kOhm • Data Storage: -Numeric Chart -Graphic Trend and -EEG waveform full disclosure -CRG trend • Display features: -EEG waveforms -EEG waveform + Trend of BIS and EMG -BIS value and alarm limit -EMG and SQl at vertical bars -SR, BC, TP numeric display • Alarms: -High BIS alarm: 0 - 100 -Low BIS alarm: 0 - 100 Your healthcare, we care. Anesthetic Gases Module • Agent Gas External Module with Automatic 5 Agent Identification • Size: (WxDxH) 145x350x90 mm / 5.75x13.75x3.5 in • Weight 3.85 kg / 8.5 lbs • Power: Input Voltage 100 to 240 Vac - 48 to 62 Hz • Sampling Gas Flow Rate: 120 ml / min • Environment: -Temperature: +10 to +40°C / +50 to 104°F -Humidity: 10 to 95% RH (non-condensing) -Barometric Pressure / Altitude: 525mmHg to 790mmHg / -305 m to + 3,048 m Gas Specification Gas Breath Rate Calculated from N 2 O + Agent M7800 Patient Monitoring System Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA GL9000 October 2012
Open the catalog to page 1All Oricare catalogs and technical brochures
-
V8600 Ventilator
6 Pages
-
L2700 Series
6 Pages
-
T3600
16 Pages
-
T3600 Operating Table
8 Pages
-
P1000 Series
12 Pages
-
Anesthetic A9040 Vaporizer
2 Pages
-
A9600 Anesthesia Workstation
6 Pages
-
C4500 Medical Air Compressor
2 Pages
-
V8800
6 Pages
-
A9800
6 Pages
-
M7600/M7400
6 Pages
-
V8800 Ventilator System
2 Pages
Archived catalogs
-
T3600 Operating Table
6 Pages
-
A9600 Anesthesia Workstation
2 Pages