1. Catalogs
  2. Oricare
  3. M7810 Patient Monitoring System

M7810 Patient Monitoring System

M7810 Patient Monitoring System

M7810 Patient Monitoring System

Product catalog summary
Overview: The M7810 Patient Monitoring System is designed for use in various clinical settings such as Operating Rooms, Intensive Care Units, and Neonatal Intensive Care Units. It offers a flexible, user-friendly interface with a 17” touchscreen display capable of showing up to 15 waveforms. The system is modular, allowing for expansion and customization to meet specific clinical needs.
Physical Specifications: The display unit measures 425mm x 245mm x 384mm and weighs 31lb/14kg with the XM module and recorder. The module rack measures 503mm x 169mm x 148mm and weighs 5.5lb/2.5kg without modules.
Display and Recording: The system features a 17” color TFT LCD with a resolution of 1280 x 1024. An optional strip chart recorder is available with print speeds of 12.5, 25, and 50mm/s.
ECG and RESP Monitoring: Supports 3, 5, and optional 12-lead ECG with various gain settings and sweep speeds. The RESP method uses trans-thoracic impedance with a range of 0-120rpm for adults and 0-150rpm for neonates/pediatrics.
SpO2 and NIBP Monitoring: The XM module measures SpO2 with a range of 0-100% and a pulse rate range of 25-300bpm. NIBP measurements vary by patient type, with specific ranges for adults, pediatrics, and neonates.
Additional Monitoring Capabilities: Includes temperature, IBP, cardiac output, CO2, and anesthetic gas monitoring. The system supports up to 8 IBP channels and offers various modules for expanded functionality.
Power and Connectivity: The system operates on AC power and includes a rechargeable Li-ion battery. Connectivity options include USB, VGA, DVI, RS-232, and network RJ-45 interfaces.
Features and Options: The M7810 is equipped with arrhythmia and S-T segment analysis, pacemaker detection, and defibrillator protection. It supports HL-7 network and electronic record integration, and offers a range of optional modules for enhanced monitoring capabilities.
Mounting and Configuration: The system can be mounted on anesthesia machines, shelves, or walls using GCX solutions. It is configurable with user-defined screens and offers a variety of display modes for different clinical needs.
Conclusion: The M7810 Patient Monitoring System is a versatile and reliable solution for high-acuity clinical environments, offering advanced monitoring capabilities and modular flexibility to adapt to various patient care scenarios.
See more

Catalog excerpts

M7810 Patient Monitoring System-1

M7810 Specifications Physical Specification • M7810 Dimensions: Display Unit: 425mm(L) x 245mm(W) x 384mm(H) 16.7”(L) x 9.6”(W) x 15.1”(H) • M7810 Dimensions: Module Rack: 503mm(L) x169mm(W) x 148mm(H) 19.8”(L) x 6.7”(W) x 5.8”(H) • M7810 Weight: Display Unit with XM module and recorder: 31lb./14kg • M7310 Weight: Module Rack (with no modules) 5.5lb/2.5kg • Module weights vary, contract Oricare for details by module. Display • Type: Color TFT LCD 17” • Resolution: 1280 x 1024 • Waves Displayed: 15 max Strip Chart Recorder (optional) • Print speed: 12.5, 25, 50mm/s • Traces: 3 • Record width: 48mm ECG • Lead Types: 12-lead(optional), 5-lead, 3-lead • Gain: Auto, x0.125(1.25mm/mV), x0.25, x0.50, x1, x2, x4(40mm/mV) • Sweep Speed: 6.25, 12.5, 25. 50mm/s • ECG HR Range: Adult: 15 – 300bpm Pediatric/Neonate: 15 – 350bpm • Resolution: 1bpm • Accuracy: +/-1bpm or +/-1% • Bandwidth: Diagnostic Mode: 0.05 – 150Hz • Monitoring Mode: 0.5 – 40Hz • Surgical Mode: 1 – 20Hz • S-T Segment Detection: Measurement Range: -2.0mV – +2.0mV • Alarm Range: -2.0mV – +2.0mV RESP • Method: Trans-thoracic Impedance • Operation Mode: Auto/Manual • RR Measurement Range: Adult: 0 – 120rpm: Neonate/Ped. 0 – 150rpm • Resolution: 1rpm • Accuracy: +/-2rpm • Apnea Alarm Threshold: 10, 15, 20, 25, 30, 35, 40 sec. • Sweep Speed: 6.25, 12.5, 25.50mm/s SpO2(in XM module) • Meas.& Alarm Range: 0 – 100% • Resolution: 1% • Accuracy: +/-2% (70 – 100%, Adult, Pediatric); +/-3% (70 – 100%, Neo.) • PR Range: 25 – 300bpm • Resolution: 1bpm • Accuracy: +/-2bpm • Refresh Rate: 1sec. SpO2 (Nellcor Oximax module) • Measurement & Alarm Range: 1 – 100% • Resolution: 1% • PR Range: 20 – 300bpm • Resolution: 1bpm • Accuracy: +/-3bpm (depends on probe) • Refresh Rate: 1sec. NIBP (in XM module) • Measurement Ranges: • Adult: Systolic Pressure: 40 – 270mmHg Diastolic Pressure: 10 – 215mmHg Mean Art. Pressure: 20 – 235mmHg • Pediatric: Systolic Pressure: 40 – 200mmHg Diastolic Pressure: 10 – 50mmHg Mean Art. Pressure: 20 – 165mmHg • Neonate: Systolic Pressure: 40 – 135mmHg Diastolic Pressure: 10 – 100mmHg Mean Art. Pressure: 20 – 110mmHg Pulse Rate: 40 – 240bpm NIBP (OMRON Module) • Method: Oscillometric • Modes: Auto, Man., Continuous • Measurement Ranges: • Adult/Pediatric: Systolic Pressure: 60 – 250mmHg Diastolic Pressure: 40 – 200mmHg Mean Art. Pressure: 45 – 235mmHg • Neonate: Systolic Pressure: 40 – 120mmHg Diastolic Pressure: 20 – 90mmHg Mean Art. Pressure: 30 – 100mmHg • Pulse Rate: ADT/PED 40 – 200,NEO 40 – 240 • Pressure Accuracy (SP10: 2002): Max mean error: +/-5mmHg Max Standard Deviation: 8mmHg Temperature • Measurement/Alarm Range: 0 – 50°C (3 – 122°F) • Resolution: 0.1°C (0.1°F) • Accuracy: +/-0.1°C (+/-0.2°F) • Channels: 2; provides T1, T2, ∆T IBP • Channels: 2 or 4 • Site Labels: ART, PA, CVP, RAP, LAP, ICP, P1, P2 • Measurement Range: -50 – 300mmHg • Resolution: 1mmHg • Accuracy: +/-2% or +/-1mmHg • Sensitivity: 5µV/V/mmHg • Impedance Range: 300 – 3000Ohm C.O. (V-CO module) • Method: Thermodilution • Measuring Range: • C.O.: 0.1L/min to 20L/min • Tblood: 23°C – 43°C • Tinjectate: -1°C – 27°C CO2 (V-CO2 module) • Type: Sidestream or Mainstream • Range: 0 – 150mmHg • Accuracy: +/-2mmHg 0 – 40mmHg +/-5% 41 – 70mmHg +/-8% 71 – 100mmHg +/-10% 101 – 150mmHg • AwRR Range: 0 – 150rpm • AwRR Accuracy: +/-1rpm Anesthetic Gas/O2 (V-AG module) • Technology: Infrared Absorption • Paramagnetic Oxygen: optional • Gases: CO2, O2, N2O, Des, Iso, Enf, Hal, Sev with Auto Agent ID • Warm-up time: Mainstream: IRMA AX+: Iso 45s Full accuracy mode: 60s Sidestream: <20s • Sample Flow Rate: 50+/-10ml/min Power Supply • AC Power: 100 – 240VAC 50/60Hz • Battery Technology: Rechargeable Li-ion • Number of Battery: 1 (standard), 1 (option) Interfaces • Analog output, Defib.Sync., Nurse Call, USB (4 or 8), VGA, DVI, RS-232, Module Rack interface (PAM), Network RJ-45 Manufactured for: Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA GL9007 June 2014 0123 Your healthcare, we care. Tel: -1-215-538-2470 Fax: -1-215-538-2578 [email protected] www.oricaremed.com Rx Only M7810 Patient Monitoring System

 Open the catalog to page 1
M7810 Patient Monitoring System-2

Clinical Performance and User Friendly Advanced Features and Connectivity M7810 Modular Patient Monitor is easy to use, reliable and flexible to match your patient’s needs. Whether at work in the Operating Room, Post-Anesthesia Care Unit, Intensive Care Area, NICU or other Medium to High Acuity area, this monitor includes the features and technology you need at a price that makes it an outstanding value. The large 17” Touchscreen is easy to use and view. The optional module rack allows for expansion into the most demanding clinical environments. The M7810 monitor features large storage capacity...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.