T3600 - 1

Your healthcare, we care. T3600 Operating Table Oricare Inc. 1900 AM Drive Quakertown, PA 18951 USA Tl9005 September 2012

Open the catalog to page 1
T3600 - 2

Table position display Lateral tilt left Lateral tilt right Back plate down ‘One-key reset’ makes post-surgery table positioning easier and more convenient. Table down Reverse Trendelenburg Flex position Re-flex position Auto-lock system of T3600 improves clinical safety. Table locked Table released Once the table’s position is adjusted by the controller, the table base will lock automatically. This function prevents possible surgical accidents which could occur by forgetting to lock the table base. Furthermore, if table is not utilized within the first minute, the controller will...

Open the catalog to page 2
T3600 - 3

Table position display Lateral tilt left Lateral tilt right Back plate down ‘One-key reset’ makes post-surgery table positioning easier and more convenient. Table down Reverse Trendelenburg Flex position Re-flex position Auto-lock system of T3600 improves clinical safety. Table locked Table released Once the table’s position is adjusted by the controller, the table base will lock automatically. This function prevents possible surgical accidents which could occur by forgetting to lock the table base. Furthermore, if table is not utilized within the first minute, the controller will...

Open the catalog to page 3
T3600 - 4

Head plate folds up/down Leg plates fold up/down. Leg plates split 180º. Leg and head plates use common ports. Positions of leg and head plates can be exchanged quickly. Therefore, X-ray radiolucent area is expanded. Built-in elevator kidney-bridge, which has no negative effect on X-ray radiolucency procedure, supports kidney and gallbladder surgery efficiently. The table plate is made of environment-friendly material which has outstanding x-ray radiolucency.

Open the catalog to page 4
T3600 - 5

Head plate folds up/down Leg plates fold up/down. Leg plates split 180º. Leg and head plates use common ports. Positions of leg and head plates can be exchanged quickly. Therefore, X-ray radiolucent area is expanded. Built-in elevator kidney-bridge, which has no negative effect on X-ray radiolucency procedure, supports kidney and gallbladder surgery efficiently. The table plate is made of environment-friendly material which has outstanding x-ray radiolucency.

Open the catalog to page 5
T3600 - 6

Two control modes: Corded hand control and override control panel on the support column. This redundant surgical position control system provides a back-up adjustment method to the user and guarantees safety. Three-level square support column is constructed of high quality stainless steel , which is easy to clean. The patented hydraulic cylinder ensures consistent operation of the table. On a fully-charged battery, maximum working time of the table is 15 days. Operating on battery power enhances the safety of surgeries since there is no connection to an AC power supply. High quality...

Open the catalog to page 6
T3600 - 7

Two control modes: Corded hand control and override control panel on the support column. This redundant surgical position control system provides a back-up adjustment method to the user and guarantees safety. Three-level square support column is constructed of high quality stainless steel , which is easy to clean. The patented hydraulic cylinder ensures consistent operation of the table. On a fully-charged battery, maximum working time of the table is 15 days. Operating on battery power enhances the safety of surgeries since there is no connection to an AC power supply. High quality...

Open the catalog to page 7
T3600 - 8

Options Knee crutch Many specialized options available for the operating table allow it to be used to support a multitude of body positions and procedures. Round-hole clamp Body strap Hand Operating Table ‘L’ style anesthesia screen Lateral support

Open the catalog to page 8
T3600 - 9

Options Knee crutch Many specialized options available for the operating table allow it to be used to support a multitude of body positions and procedures. Round-hole clamp Body strap Hand Operating Table ‘L’ style anesthesia screen Lateral support

Open the catalog to page 9
T3600 - 10

T3600 Electronic Table Options List Options(standard with Operating Table) Order Part number Round-hole Clamp Body Strap Anesthesia Screen Assembly Lateral Support Assembly Knee Crutch Assembly Drainage Bowl High Position Arm Holder Options (optional) Part Number High Position Arm Holder Head Rest Hand Operating Table Instrument Tray Iliac Support Infusion Stand Notched Clamp Connection Bracket Drainage Bowl Iliac Support Foot Plate Instrument Tray Orthopedics Traction Foot Plate

Open the catalog to page 10
T3600 - 11

T3600 Electronic Table Options List Options(standard with Operating Table) Order Part number Round-hole Clamp Body Strap Anesthesia Screen Assembly Lateral Support Assembly Knee Crutch Assembly Drainage Bowl High Position Arm Holder Options (optional) Part Number High Position Arm Holder Head Rest Hand Operating Table Instrument Tray Iliac Support Infusion Stand Notched Clamp Connection Bracket Drainage Bowl Iliac Support Foot Plate Instrument Tray Orthopedics Traction Foot Plate

Open the catalog to page 11
T3600 - 12

Orthopedics Traction System Connecting Plate For Head Rest Horseshoe Head Support and Infusion Stand Narrow Head Plate Horseshoe Head Support Orthopedics Traction System (Storage) T3600 Operating Table

Open the catalog to page 12
T3600 - 13

Orthopedics Traction System Connecting Plate For Head Rest Horseshoe Head Support and Infusion Stand Narrow Head Plate Horseshoe Head Support Orthopedics Traction System (Storage) T3600 Operating Table

Open the catalog to page 13
T3600 - 14

T3600 is a high quality Electro hydraulic operating table that satisfies the most demanding world-wide clinical safety requirements and national standards. With its advanced configuration, its high quality materials, and its flexible and convenient operating system the T3600 will be the best choice for the modern operating room. The T3600 features a wide adjustment range for all position settings in order to satisfy the demands of many different types of surgeries. Technical Specifications Table Length Table Width(without side rails) Lateral Tilt (left/right) Back Plate Up/Down Head Plate...

Open the catalog to page 14
T3600 - 15

T3600 is a high quality Electro hydraulic operating table that satisfies the most demanding world-wide clinical safety requirements and national standards. With its advanced configuration, its high quality materials, and its flexible and convenient operating system the T3600 will be the best choice for the modern operating room. The T3600 features a wide adjustment range for all position settings in order to satisfy the demands of many different types of surgeries. Technical Specifications Table Length Table Width(without side rails) Lateral Tilt (left/right) Back Plate Up/Down Head Plate...