Modes of Ventilation:
The V8800 Ventilator supports various ventilation modes including Volume Controlled (VCV), Pressure Controlled (PCV), Pressure Regulation Volume Controlled (PRVC), Synchronized Intermittent Mandatory Ventilation (SIMV) with Pressure Support Ventilation (PSV), Spontaneous Ventilation (SPONT/CPAP) with PSV, Bi-Level Ventilation (BIVENT/APRV) with PSV, and Non-invasive Ventilation (NIV/CPAP + PSV, NIV/PCV).
Parameters and Ranges:
Key parameters include a respiratory rate of 1-120 bpm, inspiration time of 0.2-9 seconds, FiO2 range of 21%-100%, and PEEP range of 0-50 cmH2O. Other parameters include CPAP(NIV), Psupport, Pinsp, Phigh, Plow, Esens, and flow patterns.
Technical Parameters:
The V8800 monitors volume/flow values, pressure values, and includes alarms for various conditions such as high airway pressure and low battery. It operates on a power supply of 100-240V and supports communication interfaces like RS232, VGA, USB, and RJ45.
Standards:
The ventilator complies with standards such as UL/IEC 60601-1, IEC 60601-1-2, IEC 60601-2-12, and EN 794-1.
Design and Features:
The V8800 features a 15” TFT LCD touch screen with a rotatable display for ease of use. It includes powerful monitoring functions, lung mechanics monitoring, and the ability to add modules like a humidifier. Enhanced features include automatic tube compensation and NIV Ventilation as standard.
Clinical Features:
The ventilator offers synchronized nebulizer, inspiratory and expiratory hold, manual inspiration, and smart suction. It is designed for use with infants, children, and adults, providing comprehensive functionality for critical care.
See more

Catalog excerpts

V8800 Ventilator System-1

Your healthcare, we care. V8800 Ventilator Technical Parameters V8800 Modes of Ventilation Monitoring ·Volume Controlled (VCV), Assist/Control ·Pressure Controlled (PCV), Assist/Control ·Pressure Regulation Volume Controlled (PRVC), Assist/Control ·Synchronized Intermittent Mandatory Ventilation, SIMV(VCV) + PSV, SIMV(PCV) + PSV, SIMV(PRVC) + PSV ·Spontaneous Ventilation (SPONT/CPAP) + PSV ·Bi Level Ventilation (BIVENT/APRV) + PSV ·Non-invasive Ventilation (NIV/CPAP + PSV, NIV/PCV) ·Pressure values: Pmin, Pplat, Pmean, Ppeak, PEEP ·Volume/Flow values: VTI, VTE, MV, MVspont, Leak% ·Loops: Flow – Pressure, Pressure - Volume, Flow - Volume ·FiO 2 ·Optional EtCO 2 Parameters and Ranges ·Tidal volume: 20-2500ml ·Respiratory rate: 1-120bpm ·Inspiration time: 0.2-9s ·Inspiratory pause time: 0~4s ·Tslope: 0~2s ·FiO 2 : 21%~100% ·PEEP: 0-50cmH 2 O ·CPAP(NIV): 2-20cmH 2 O ·Psupport: 0-90cmH 2 O ·Pinsp: 5-90cmH 2 O ·Phigh: 5-90cmH 2 O ·Plow: 0-50cmH 2 O ·Esens: 5%~80% ·Flow patterns: square, decelerating ·Inspiratory hold ·Expiratory hold ·Nebulizer: 30 or 45 minutes ·Auto tube compensation (ATC) ·Compliance compensation ·Graphical trends ·Nurse call Ventilator System Alarms MV high, MV low, Circuit disconnect, Paw high, Paw low, Continuous airway pressure high, VTi high, fspont high, Tapnea, FiO 2 high, FiO 2 low, EtCO 2 high, EtCO 2 low, Power supply failure, Battery low, Battery exhausted, Air supply failure, O 2 supply failure, PEEP low, etc Operating Conditions ·Gas supply: O 2 , Air, 200kPa -650kPa (29 – 94 PSI) ·Power supply: 100-240V, 50-60Hz ·Temperature: 10-40℃(Operation) ·-20-60℃ (Storage) ·Relative humidity: 15-95%, non-condensing (Operation) ·≤95%, non-condensing (Storage) ·Atmospheric pressure: 500hPa-1060hPa (Operation & Storage) ·Communication interfaces: RS232, VGA, USB, RJ45 ·Dimensions (H×W×D): 624x774x1410mm (with Cart) Standards UL/IEC 60601-1, IEC 60601-1-2, IEC 60601-2-12, EN 794-1 Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA VL9002 October 2011 Tel: +1-215-538-2470 Fax: +1-215-538-2578 www.oricaremed.com

 Open the catalog to page 1
V8800 Ventilator System-2

V8800 Ventilator System V8800 is a critical care ventilator for infants, children and adults. It has comprehensive functionality, a user-friendly design, and is full of high-quality, reliable treatment options for the clinician. V8800 Ventilator System Simple and intuitive interface: With a 15” TFT LCD touch screen and a simple intuitive interface, the user can easily complete the entire operation. At the same time the display can be rotated 180 degrees around the user in different directions, different angles of observation and action. Powerful monitoring functions: · Complete ventilation functionality:...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.