1. Catalogs
  2. Ortho Development
  3. Ovation® Surgical Technique

Ovation® Surgical Technique

Ovation® Surgical Technique
1 / 10 PagesView full catalog

Ovation® Surgical Technique

Product catalog summary
Overview: This document serves as a detailed guide for the surgical technique of the Ovation® Hip Stem, developed by surgeons Andrew Petrella, M.D., and Richard Vlasak, M.D. It is tailored for surgeons experienced in Total Hip Arthroplasty (THA) and highlights the necessity for case-specific adjustments based on the surgeon's expertise.
Device Description: The Ovation® Hip Stem is characterized by a reliable M/L taper design, adaptable to various surgical approaches. It ensures excellent rotational stability, simplifies the surgical process with minimal tools, and features optimized neck geometry for enhanced motion range. The stem is available in 12 sizes with both standard and extended neck offsets, coated with titanium plasma spray for durable fixation.
Preoperative Planning: Essential preoperative templating with 20% magnification templates is recommended to estimate the correct implant size and identify any anomalies. These templates should be used alongside standard preoperative lateral and A/P radiographs.
Surgical Technique: The procedure includes several critical steps:
  • Incision: The Ovation® Hip Stem can be implanted using Anterolateral, Posterolateral, or Direct Anterior approaches.
  • Femoral Neck Osteotomy: The femoral neck is cut according to the pre-determined template level.
  • Femoral Preparation: Utilizes a Box Osteotome and Starter Reamer to prepare the femur for broaching.
  • Trial Reduction: Involves selecting appropriate Neck and Femoral Head Trials to evaluate stability and motion range.
  • Femoral Component Insertion: The chosen Ovation® Hip Stem is inserted into the canal, followed by trial reduction to ensure proper seating and rotation.
  • Hip Reduction: The hip is reduced and tested through a full range of motion to confirm the desired outcome.
Instrumentation and Implants: The document details various instruments and implants, including Broaches, Neck Trials, Femoral Head Trials, and Ovation Stems, with specific part numbers and descriptions.
Conclusion: It stresses the importance of adhering to the Ovation® Hip Stem Instructions for Use (IFU) for comprehensive information on intended uses, contraindications, precautions, warnings, and potential risks.
Product Specifications: The document lists different models of CoCr (Cobalt Chromium) Femoral Heads used in orthopedic implants, available in sizes 28mm, 32mm, 36mm, and 40mm with offsets from -6mm to +9mm.
Company Information: Ortho Development Corporation, established in 1994, specializes in the design, manufacture, and distribution of orthopedic implants and surgical instruments, focusing on hip and knee joint replacement, trauma fracture repair, and spinal fixation. Based in Draper, Utah, the company distributes its products in the U.S., Japan, and select international markets.
Legal Notice: The document is copyrighted by Ortho Development Corporation. Reproduction or modification for purposes other than personal use is prohibited without prior written permission.
See more

Catalog excerpts

Ovation® Surgical Technique-2

Designing Surgeons: Andrew Petrella, M.D. Richard Vlasak, M.D. Table of Contents Surgical Technique Overview The following technique is a general guide for instrumentation of the Ovation® Hip Stem. It is expected that the surgeon is already familiar with the fundamentals of Total Hip Arthroplasty (THA). Each patient represents an individual case that may require modification of the technique according to the surgeon’s judgment and experience. Please see the Ovation® Hip Stem Instructions for Use (IFU) for intended uses/indications, device description, contraindications, precautions, warnings...

 Open the catalog to page 2
Ovation® Surgical Technique-3

Surgical Technique Overview • ptimized neck geometry with highly polished surface O improves overall range of motion • vailable in 12 sizes with standard and extended neck A The Ovation® Hip Stem is a proven M/L taper design that offsets to accommodate patient anatomy accommodates multiple surgical approaches. In order to P provide options for various patient needs, the Ovation® Hip • roximal body surface is coated with titanium plasma spray for solid, long-term fixation Stem is available in a full range of sizes. • apered stem design provides excellent rotational T stability and promotes 3-point...

 Open the catalog to page 3
Ovation® Surgical Technique-4

Templates with a 20% magnification are provided by Ortho Development® Corporation for use with preoperative x-rays. Preoperative templating enables the surgeon to estimate the correct implant size as well as to identify any unusual circumstances specific to the case at hand. The templates should be used with standard preoperative lateral and A/P radiographs to determine the approximate size and position of the prosthesis (Figure 1). 3. ncision I In Total Hip Arthroplasty, exposure may be achieved through a multitude of methods based on each surgeon’s individual preference. The Ovation® Hip Stem...

 Open the catalog to page 4
Ovation® Surgical Technique-5

Increase the Broach size sequentially until the Broach size matches the implant size determined during preoperative templating, or until sufficient stability of the Broach has been achieved. Rotational stability of the Broach is tested by turning the Broach Handle back and forth. Once the final Broach size has been determined to be stable, remove the Broach Handle and leave the Broach in place for trialing. If desired, with the final Broach inserted to the proper level, attach the Calcar Planar to a power driver and connect it to the Broach’s post (Figure 8). Advance the Calcar Planer into the...

 Open the catalog to page 5
Ovation® Surgical Technique-6

7. emoral Component F Insertion Once the Femoral Stem implant is in place, trial reduction may be performed once again to check for proper seating, rotation, and to ensure the appropriate femoral head neck length is selected (Figure 12). Based on the trial reduction, the appropriate Femoral Head implant is selected by matching the desired head diameter and length to the last Femoral Head Trial used. The selected Femoral Head is placed onto the taper of the stem by hand using extreme care to keep the stem taper undamaged and clean from soft tissue or bone. Lightly tap the Femoral Head with the...

 Open the catalog to page 6
Ovation® Surgical Technique-7

Ovation® Instrument Trays Blunt Tip Broach Size 1 Blunt Tip Broach Size 2 Neck Trial Size 1-3 Standard Neck Trial Size 4-6 Standard Blunt Tip Broach Size 4 Neck Trial Size 7-9 Standard Blunt Tip Broach Size 5 Neck Trial Size 10-12 Standard Blunt Tip Broach Size 6 Neck Trial Size 4-6 Extended Neck Trial Size 7-9 Extended Neck Trial Size 1-3 Extended Neck Trial Size 10-12 Extended Blunt Tip Broach Size 8 Blunt Tip Broach Size 9 Blunt Tip Broach Size 7 Blunt Tip Broach Size 10 Femoral Head Impactor Large Calcar Planar 40mm Femoral Head Impactor Large Hudson T-Handle Offset Stem Inserter Right Femoral...

 Open the catalog to page 7
Ovation® Surgical Technique-8

Ovation® Implants Femoral Head Trial 22mm -3 Femoral Head Trial 22mm +0 Femoral Head Trial 22mm +3 Femoral Head Trial 22mm +6 Femoral Head Trial 26mm -3 Femoral Head Trial 26mm +0 Femoral Head Trial 26mm +3 Femoral Head Trial 26mm +6 Femoral Head Trial 26mm +9 Femoral Head Trial 28mm -6 Femoral Head Trial 28mm -3 Femoral Head Trial 28mm +0 Femoral Head Trial 28mm +3 Femoral Head Trial 28mm +6 Femoral Head Trial 28mm +9 Femoral Head Trial 32mm -6 Femoral Head Trial 32mm -3 Femoral Head Trial 32mm +0 Femoral Head Trial 32mm +3 Femoral Head Trial 32mm +6 Femoral Head Trial 32mm +9 Femoral Head Trial...

 Open the catalog to page 8
Ovation® Surgical Technique-9

Biolox® Delta Femoral Head 28mm S -5 Biolox® Delta Femoral Head 28mm M -1 Biolox® Delta Femoral Head 28mm L +2 Biolox® Delta Femoral Head 32mm S -5 Biolox® Delta Femoral Head 32mm M -1 Biolox® Delta Femoral Head 32mm L +2 Biolox® Delta Femoral Head 32mm XL +6 Biolox® Delta Femoral Head 36mm S -5 Biolox® Delta Femoral Head 36mm M -1 Biolox® Delta Femoral Head 36mm L +2 Biolox® Delta Femoral Head 36mm XL +6 Biolox® Delta Femoral Head 40mm S -5 Biolox® Delta Femoral Head 40mm M -1 Biolox® Delta Femoral Head 40mm L +2 Biolox® Delta Femoral Head 40mm XL +6 CoCr Femoral Head 28mm +3 CoCr Femoral Head...

 Open the catalog to page 9
Ovation® Surgical Technique-10

12187 So. Business Park Drive Draper, Utah 84020 801-553-9991/fax 801-553-9993 Copyright © 2013 Ortho Development® Corporation. All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by Ortho Development Corporation. All rights reserved. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior...

 Open the catalog to page 10