Finetest AC

Finetest AC
1 / 24 PagesView full catalog

Finetest AC

Product catalog summary
Introduction
The Finetest Auto-coding™ Premium Blood Glucose Monitoring System is intended for in vitro diagnostic use, specifically for self-testing blood glucose levels using fresh capillary whole blood samples. It is not suitable for diagnosing diabetes or testing newborns.
Specifications and Features
The system includes a blood glucose test meter, test strips, a lancing device, sterile lancets, and other accessories. Key features include automatic coding, a test strip ejector, and a plasma-calibrated system for easy comparison with laboratory results. The meter requires a 1.5㎕ blood sample, stores up to 365 test results, and calculates average sugar levels over preset days.
Usage Instructions
Users should follow instructions carefully, consult healthcare professionals for diabetes management, and handle blood properly to avoid health hazards. The system should be kept out of reach of children and stored away from direct sunlight and moisture.
Maintenance and Care
Do not disassemble the meter. Keep it dry and clean, and avoid exposure to chemicals or direct sunlight. Replace batteries as needed and dispose of the meter and batteries properly.
Testing Procedure
Set up the meter, check the system with a glucose control solution, and perform a control solution test before testing. Collect a drop of blood and follow the testing procedure. The system automatically turns off if not used within 5 minutes.
Results and Troubleshooting
Review and delete test results as needed. Consult a healthcare professional if results are inconsistent or fall outside the normal range. The system includes troubleshooting guidance for common issues.
Limitations and Interferences
The test strips are for single use and should not be reused. Conditions like dehydration or high altitudes may affect results. Interferences from substances like acetaminophen and vitamin C are minimal at normal concentrations.
Warranty and Support
The product comes with a warranty, and users are encouraged to contact local representatives for support or if any parts are missing or damaged.
Testing Procedures
Insert the test strip correctly to turn on the meter and display the code, temperature, date, and time. Apply blood to the test strip; the meter will count down from 9 seconds and display results. Avoid testing under direct sunlight for accurate results.
Control Solution Testing
Use glucose control solution to check the meter and test strip functionality. Perform tests when results are inconsistent, after dropping the meter, or for quality control.
Blood Sample Collection
Use a lancing device with sterile lancets for single use only. Collect blood from alternative sites like the arm or palm, ensuring the area is clean and dry.
Precautions and Recommendations
Do not share lancing devices or lancets to prevent infection. Store lancets at room temperature, away from sunlight and moisture. Discard used test strips and lancets in biohazard containers.
Data Management
Review stored results and averages using the meter's built-in memory. Delete individual or all test results as needed.
Alternative Site Testing
Alternative sites include the dorsal hand, ventral palm, upper arm, forearm, calf, and thigh. Be aware that results from alternative sites may differ from fingertip samples, especially when blood glucose levels are changing rapidly.
Alternate Site Testing Guidelines
Use alternate site samples for testing only before meals or more than two hours after meals, insulin doses, or physical exercise. Fingertip testing is recommended within two hours after meals, insulin doses, or exercise, or when glucose levels may be changing rapidly.
Software and Data Transfer
Test results can be transferred from the meter to a computer using software available on the Infopia website. A specific USB cable is required for data transfer.
Blood Test Procedure Using Alternate Site
Rub the test site to bring fresh blood to the surface, lance the site, and apply the test strip to the blood drop.
Battery Replacement
The meter uses two 3V Lithium batteries (CR2032). Replace when the low battery icon appears. After replacing batteries, recheck meter settings and perform a control solution test.
Cleaning and Maintenance
Clean the meter with a damp cloth and mild detergent. Avoid liquids on the meter. Clean the lancet device with soap and water, and disinfect with a bleach solution.
Troubleshooting
Various error messages and solutions are provided for issues like test strip problems, battery issues, and inconsistent results.
Disposal Instructions
Dispose of the meter and batteries according to local regulations for electronic waste and batteries.
Specifications
Sample type: Capillary whole blood. Sample volume: 1.5㎕. Test range: 10~600 mg/dl. Reading time: 9 seconds. Operating temperature: 10-40℃ (50-104℉).
Warranty
The meter has a three-year warranty against defects, excluding misuse or damage.
See more

Catalog excerpts

Finetest AC-1

Anyang-si, Gyeonggi-do, Korea (431 V, U>) IECIREPI ObelbSJt. Brussels, Belgium IMl Lancing Device :GMMC Digital-ro, Geumcheon-gu Seoul, Korea IECIREPI Global Medical Market Corporation S.L. I'.iu lndiMii.il Gutat de Carlet Medial 20,46240 Carlet, Valenda, Spain E-mail: aricco@gmmc-inccom Full Automatic Coding Test Strip Ejector Operation Manual

 Open the catalog to page 1
Finetest AC-2

Auto-coding Premium

 Open the catalog to page 2
Finetest AC-3

Dear Finetest Auto-coding Premium System Owner TM Thank you for choosing the Finetest Auto-codingTM Premium Blood Glucose Monitoring System. This booklet has important information you must know about the Finetest Auto-codingTM Premium System. Please read it carefully. We understand that self-testing of blood glucose level provides a way to control your diabetes and may give you peace of mind by testing regularly. As a result Finetest Auto-codingTM Premium was developed to provide you with a fast and accurate reading with a convenient and simple process. Our goal at Finetest Auto-codingTM Premium...

 Open the catalog to page 3
Finetest AC-4

Finetest Auto-coding* Premium Blood Glucose Monitoring System KIT Contents ■ ■ -9 infopia co.,ltd. | Intended use of Finetest Auto-coding™ Premium Blood Glucose Test Meter The Finetest Auto-coding™ Premium Blood Glucose Monitoring System is ntended for in vitro diagnostic use only. Finetest Auto-coding™ Premium Blood Glucose Monitoring System is for self-testing. It should not be used for the diagnosis of diabetes or for the testing of The Finetest Auto-coding™ Premium was designed to test a blood glucose (sugar) level and can be used with a capillary whole blood sample. Do not use the Finetest...

 Open the catalog to page 4
Finetest AC-5

Reminders Testing during or after meal, physical exercise, or any other event that will impact glucose levels can affect your blood glucose result. Finetest Auto-codingTM Premium Blood Glucose Monitoring The Finetest Auto-codingTM Premium Blood Glucose Monitoring System is intended for use outside the body (in vitro diagnostic use only). The Finetest Auto-codingTM Premium Blood Glucose Monitoring System should be used only for testing glucose and only with fresh capillary whole blood samples. The Finetest Auto-codingTM Premium Blood Glucose Monitoring System should not be used for the diagnosis...

 Open the catalog to page 5
Finetest AC-6

I Finetest Auto-coding™Premium BlOOd GlUCOSe Meter Test Strip Port: Insert the Finetest Auto-coding Premium Test Strip here. Test Strip Ejector Display Screen Display your test results: Function Button Powers the meter on/off, prompts memory data and acts as an enter button during setup and after tests. Up/Down Arrow Buttons: Adjusts setting, scrolls through memory. -Serial Number - Battery Cover Do not use Element™ Auto-coding blood glucose test meter in a dry environment, especially if synthetic materials are present. Synthetic clothes, carpets, etc., may cause damag'ng static discharges in...

 Open the catalog to page 6
Finetest AC-7

Finetest Auto-codingTM Premium Blood Glucose Test Strip Use the Finetest Auto-codingTM Premium Test Strip with the Finetest AutocodingTM Meter and FinetestTM Meter. Apply Blood Target Confirmation Window Storage and Handling Caution 1. Keep out of direct sunlight. 2. Store the Finetest Auto-codingTM Premium Blood Glucose Test Strip vials in a cool, dry place between 2-30°C(36-86°F). Do not freeze. 3. Make a notation of the discard date on the vial label when you first open it. Discard remaining ElementTM Auto-coding blood glucose test strips 3 months after first opening the vial. 4. Close the...

 Open the catalog to page 7
Finetest AC-8

Setting your Blood Glucose meter Setting your Blood Glucose meter The Blood Glucose Monitoring System has a wide variety of functions to choose from. From the setup mode you have the ability to turn the activity / meal flags on or off, and you can also set the date/time, designate three unique averages and set up to five daily alarms. Temperature unit Press and release either or buttons to set or . Enter button. Power On Press for 3 seconds at least. User Activity Option After pressing and releasing either or buttons to turn the user Activity option on/off, confirm with Number of days for average...

 Open the catalog to page 8
Finetest AC-9

Auto-coding Function Checking the System with Glucose Control Solution How to do the Finetest Auto-codingTM Premium glucose control solution test. Step 1-1 : (refer to page 16) 1) Finetest Auto-codingTM Premium has automatic code recognition function. To check the meter and test strip with glucose control solution, when the symbol, , is displayed, press or button. Then, the symbol, , will be displayed. As the glucose control solution symbol appears, apply the glucose control solution to the test strip. 2) It recognizes automatically the code number. This is a very convenient function preventing...

 Open the catalog to page 9
Finetest AC-10

Performing a Control Solution Test The control solution should be used when there is suspicion that the meter or the strip are not working properly. For example : if strips have been exposed to extreme conditons or if you drop the meter. Performing a Control Solution Test For example If you use a normal control solution, you must use the normal range printed on the side of the strip vial. Check the expiration date before performing a control solution test. Do not used if expired. Once opened, solution expires after 3 months. Note : (In order to perform the more accurate glucose control solution...

 Open the catalog to page 10
Finetest AC-11

Testing your Blood - Preparation Before testing, be sure to read this section and test strip package insert found in the test strip box carefully. Make sure you have all the necessary items to begin the test : 1) Finetest Auto-codingTM Premium blood glucose test meter. 2) Finetest Auto-codingTM Premium blood glucose test strip. 3) Lancing Device. 4) Sterile Lancet. Caution To reduce risk of infection : Collecting a Drop of Blood The lancing device is a convenient medical tool for collecting capillary blood samples for glucose monitoring or other tests which require one or two drops of blood....

 Open the catalog to page 11
Finetest AC-12

Collecting a Drop of Blood Collecting a Drop of Blood Disposing of your lancet 1. Unscrew the tip of the lancing device by turning it counter-clockwise while holding the base firmly. 2. With two fingers, pull out the lancet carrier and hold it in place. 3. While holding the lancet carrier, insert a new sterile lancet into the bottom of lancet carrier. 1. Push the needle into the protective cover. 2. Pull the lancet out and discard accordingly. Recommended Available Lancing Device infopia®, Element™ sterile Lancet is used with a Lanzo Lancing device. 12345 5. Put the tip of the lancing device...

 Open the catalog to page 12

All OSANG Healthcare catalogs and technical brochures

  1. Gluconnect

    2  Pages

  2. SelexOn

    2  Pages

  3. LipidPro

    2  Pages

  4. Clover A1c

    2  Pages

  5. Finetest

    24  Pages

  6. GlucoLab

    22  Pages

  7. Healthpro

    24  Pages

  8. Element

    22  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.