Finetest

Finetest
1 / 24 PagesView full catalog

Finetest

Product catalog summary
Introduction
The document details the finetestTM Blood Glucose Monitoring System, emphasizing the importance of reading the manual thoroughly and consulting healthcare professionals for diabetes management.
Specifications and Intended Use
The system is for in vitro diagnostic use, specifically for testing blood glucose levels using fresh capillary whole blood samples. It is not suitable for diagnosing diabetes or testing newborns.
System Components
The kit includes a blood glucose meter, test strips, a lancing device, sterile lancets, an operation manual, a warranty registration card, a logbook, a battery, and a carrying case.
Operating Instructions
1. Insert the test strip into the meter.
2. Apply a blood sample to the test strip until the confirmation window is filled.
3. The meter displays results in 9 seconds.
4. If the confirmation window does not fill completely, discard the strip and retest.
Test Principle
The system uses a bio-sensor with glucose oxidase that reacts with glucose in the blood, measured amperometrically.
Maintenance and Storage
1. Do not disassemble the meter.
2. Keep the device dry and away from direct sunlight.
3. Store test strips in a cool, dry place and discard them three months after opening.
Control Solution Testing
Used to ensure the meter and test strips function correctly, especially when opening a new vial of test strips or if results are inconsistent.
Important Notes
1. Code the meter with each new vial of test strips.
2. Avoid using the meter near electromagnetic radiation.
3. Dispose of used test strips and lancets properly.
Warranty and Support
A three-year warranty is provided upon registration. Users are encouraged to contact local representatives for support.
Specifications and Usage Instructions
Use Finetest™ Test Strips exclusively with the Finetest™ Meter. Only fresh capillary whole blood should be used. Not suitable for neonates. Test strips are single-use only.
Interferences and Limitations
Hematocrit levels below 30% or above 55% can skew results. Substances like acetaminophen, uric acid, and vitamin C in high levels can affect results.
Performance Characteristics
Measurement range: 10 to 600 mg/dL (0.6-33.3 mmol/L).
Setting the Meter
The meter has three modes: Average period, Unit, Date & Time. Ensure the unit of measurement is set correctly.
Testing Procedure
Insert the test strip correctly, collect a blood sample, ensure the sample volume is 1.5㎕, and record results in the logbook.
Alternative Site Testing
Alternative sites include the upper arm, forearm, ventral palm, and dorsal hand.
Maintenance
Clean the meter with a damp cloth and mild detergent. Disinfect the lancing device with a bleach solution.
Cleaning and Maintenance
Use a cloth with disinfectant solution to clean the lancet device, soaking only the cap for 30 minutes.
Storage Instructions
Store the system in a cool, dry place, away from children. Avoid freezing and direct sunlight.
Usage Guidelines
Follow the manual for meter usage. Dispose of used lancets and test strips according to local regulations.
Testing Sites
Recommended testing sites include the fleshy areas of the palm, forearm, or upper arm. For hypoglycemia testing, use fingertips.
Battery Replacement
Replace the battery when low, ensuring correct polarity. The meter uses a 3.0V lithium battery, sufficient for 5,000 tests.
Data Transfer
Test results can be transferred to a computer using software available on the manufacturer's website.
Disposal Instructions
Dispose of the meter and batteries according to local regulations for electronic waste.
Troubleshooting
Common issues include improper meter settings, insufficient blood samples, and test strip problems.
Warranty
The meter comes with a three-year warranty, excluding batteries, covering defects not caused by misuse.
Specifications
The meter model IGM-0005A has a test range of 0.6 ~ 33.3 mmol/L, a reading time of 9 seconds, and a memory capacity of 200 results.
See more

Catalog excerpts

Finetest-1

Blood Glucose Monitoring System for self testing infopia Co., Ltd. 132, Anyangcheondong-ro, Dongan-gu, Anyang-si, Gyeonggi-do, Korea (431-836) www.infopia21.com Obelis S.A. Bd. General Wahis 53, 1030 Brussels, Belgium Tel: +(32) 2. 732.59.54 Fax: +(32) 2.732.60.03 E-Mail : [email protected] Lancing Device : GMMC Rm 1112, Ace Tower 9th Bldg., 130, Digital-ro, Geumcheon-gu, Seoul, Korea Global Medical Market Corporation S.L. Parc Industrial Ciutat de Carlet Mestral 20, 46240 Carlet, Valencia, Spain Tel : +34 963 691 484 Fax : +34 963 691 484 E-mail : [email protected] Lancet : infopia Co., Ltd.

 Open the catalog to page 1
Finetest-2

Blood Glucose Monitoring System for self testing

 Open the catalog to page 2
Finetest-3

System Owner Dear finetestTM System Owner Quick Reference This is intended only for quick reference. Please read the entire manual before you use the finetestTM monitoring system. Thank you for choosing the finetestTM Blood Glucose Monitoring System. This booklet has important information you must know about the finetestTM system. Please read it carefully. We understand that self-testing of blood glucose level provides a way to control your diabetes and may give you peace of mind by testing regularly. As a result finetestTM was developed to provide you with a FAST and Accurate reading with a...

 Open the catalog to page 3
Finetest-4

Important Information Important Information Before using the finetestTM Blood Glucose Monitoring System, read all of the operating instructions in this Operation Manual to practice for safe and accurate testing. Intended Use The finetestTM Blood Glucose Monitoring System is intended for use outside the body only(in vitro diagnostic use) and self-testing. The recorded results make it easier for your doctor to access your metabolic control. However, the self-testing should not take the place of overall diabetes management assessment from your doctor. It should be used only for testing blood glucose(sugar)...

 Open the catalog to page 4
Finetest-5

Learning The System finetesf" Blood Glucose Monitoring System KIT Contents i finetesf" Blood Glucose Meter 2 finetesfJ Blood Glucose Meter Display 3 finetesfJ Blood Glucose Test Strip 4 Before Testing Important finetesf " Test Strip Information 5 Checking the Meter with the Check Strip 6 Checking the System with the finetesf' Control Solution 8-12 Testing Ybur Blood Setting The Meter 13-14 Collecting a Drop of Blood 15-16 Reviewing Your Results Testing Your Blood 17-21 Reviewing Your Results 22-23 Caring for Your Meter Maintaining the finetest Meter 24 Alternative Site Test 25 Ventral palm/Dorsal...

 Open the catalog to page 5
Finetest-6

Blood Glucose Meter Blood Glucose Meter Display Test port LCD display segment Strip Code Symbol Low Battery Warning Symbol Time / Test Result Amount Blood drop symbol for test Pour utiliser avec FinetestTM Lecteur de glycémie Product Label Fabriqué par Infopia Co.,Ltd #1603, Dongil Technotown A bldg. 889-3, Kwanyang2-Dong, Dongan-Gu, Anyang, Kyunggi, 431-716, Korea infopia Co., Ltd. 891, Hogye-dong, Dongan-gu, Anyang, Kyunggi, 431-080, Korea www.infopia21.com Obelis S.A. Bd. General Wahis 53, 1030 Brussels, Belgium Tel: +(32) 2. 732.59.54, Fax: +(32) 2.732.60.03 E-Mail : [email protected] Mandataire...

 Open the catalog to page 6
Finetest-7

Blood Glucose Test Strip Test Strip Information The finetestTM System measures the amount of glucose in your blood. (Use only Finetest blood glucose test strip with your Finetest 1. Keep out of direct sunlight. blood glucose test meter) 2. Store the finetestTM Blood Glucose Test Strip vials in a cool and dry place between Blood is applied to the Top Edge of the finetest TM Test Strip and is automatically drawn into the channel where the reaction takes place Test Strip Port 3. Make a notation of the discard date on the vial label when you first open it. Discard remaining finetestTM blood glucose...

 Open the catalog to page 7
Finetest-8

Checking the Meter with the Check Strip The "Check Strip" is to make sure that the Meter functions properly. Code numbers are used to calibrate the finetestTM Meter with the finetestTM Test Strips for accurate results. You must code the meter before using it. Confirm the code number for the first time and then every time you change to another vial of test strips. STEP 1 ·The Check Strip automatically checks the Meter when inserted into the Test Port. ·Please Insert the Check Strip with“<<<”facing up into the test port of the Meter. If the value displayed is ranged between 107127, the Meter is...

 Open the catalog to page 8
Finetest-9

Checking the System with the Control Solution Checking the System with the Note: The finetestTM Control Solution is sold separately. Both, the low and high level control solution can be obtained through Infopia Co., Ltd. Refer to the finetestTM Control Solution package for additional information. Important Control Solution Test Information The finetestTM Control Solution is used to check that the Meter and the Test Strips are working together as a system and that you are performing the test correctly. It is very important that the control solution is used routinely to make sure that you receive...

 Open the catalog to page 9
Finetest-10

Checking the System with the finetestTM Test Strips provide accurate results when the following constraints are observed: • Use only the Finetest™Test Strips with the Finetest™Meter. • Use fresh capillary whole blood only. Do not use plasma or serum. • Do not use for neonate. • The test strips are for single use only. Do not reuse. • Dehydration may lower test results. If you are severely dehydrated, contact you physician immediately. How to do the finetestTM Control Solution test Physicians - Please note the following interferences that may affect test results : • Hematocrit: Extremes in hematocrit...

 Open the catalog to page 10
Finetest-11

Checking the System with the Control Solution STEP 3: Result appears in 9 seconds The finetestTM Meter has three functional modes as settings: 1) Average period, 2) Unit, 3) Date & Time. If you need to change the time, or if you remove the battery, you may need to enter the setting mode and reset. Once you hear the “beep” it indicates that the test strip is filled and the meter will begin to count down from , “9” seconds to “1” second Turn on the meter by pressing the SET button for 3 seconds. This will initiate the “Set the Meter”mode. and the control solution test result will be displayed (picture...

 Open the catalog to page 11

All OSANG Healthcare catalogs and technical brochures

  1. Gluconnect

    2  Pages

  2. SelexOn

    2  Pages

  3. LipidPro

    2  Pages

  4. Clover A1c

    2  Pages

  5. GlucoLab

    22  Pages

  6. Finetest AC

    24  Pages

  7. Healthpro

    24  Pages

  8. Element

    22  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.