Introduction
The document details the GLUCOLABTM Auto-coding Blood Glucose Monitoring System, emphasizing its use for self-testing blood glucose levels and the importance of consulting healthcare professionals for diabetes management. It is intended for in vitro diagnostic use only.
Specifications and Intended Use
The system is designed for testing blood glucose using fresh capillary whole blood samples, not for diagnosing diabetes or testing newborns. It is plasma-calibrated for comparison with laboratory methods.
Test Principle
The system uses glucose oxidase on test strips to measure blood glucose levels, with calibration done using the YSI 2300 STAT plus system.
Maintenance and Handling
Users should not disassemble the meter, keep it dry, and store it away from chemicals and sunlight. It contains small parts and should be kept out of reach of children.
System Components
The kit includes a test meter, test strips, lancing device, lancets, operation manual, warranty card, patient logbook, carrying case, and batteries.
Testing Procedures
Instructions cover setting up the meter, performing glucose control solution tests, and testing blood glucose levels, with auto-coding for convenience.
Limitations and Interferences
Conditions affecting test accuracy include dehydration, high altitudes, and substances like acetaminophen and vitamin C. The hematocrit range for accurate results is specified.
Performance Characteristics
The measurement range is 10 to 600 mg/dL. Proper handling and storage of test strips are advised to ensure accuracy.
Additional Features
The meter includes alarms, user ID options, and activity tracking related to test results, along with a conversion table for different measurement units.
Troubleshooting and Support
Guidance is provided for troubleshooting common issues, with customer support available for assistance.
Glucose Control Solution Testing
Instructions for using the glucose control solution include inserting a test strip, differentiating between control and actual tests, and comparing results to the range on the test strip vial.
Collecting a Drop of Blood
Use a new lancet and test strip for each test, wash hands thoroughly, and dispose of used lancets in a biohazard container.
Testing Procedure
Insert the test strip, apply a blood sample, and wait for results, which appear in 5 seconds. Record results and dispose of materials properly.
Reviewing and Deleting Results
The meter stores up to 365 test results, which can be reviewed and deleted using the meter's buttons.
Alternate Site Testing
Alternate sites include the forearm, upper arm, hand, thigh, and calf, used only when blood glucose is stable.
Precautions
Do not share lancing devices or lancets, avoid testing under direct sunlight, and ensure proper storage of components.
GLUCOLABTM Auto-coding Blood Glucose Test Meter Overview
The document provides instructions and specifications for the meter, including software usage, maintenance, troubleshooting, and warranty information.
Specifications
Details include sample type, volume, test range, reading time, calibration, operating conditions, and power requirements.
Procedures
Instructions for blood testing and battery replacement are provided, emphasizing proper sample application and meter settings.
Maintenance and Cleaning
Clean the meter with a damp cloth and mild detergent, disinfect the lancing device, and store the meter in a cool, dry place.
Troubleshooting
Guidance is provided for issues like the meter not powering on or inconsistent results, with advice to consult a doctor if abnormal readings persist.
Warranty
The meter has a three-year warranty covering defects, excluding misuse or damage, applicable to the original purchaser.
Environmental and Disposal Information
Dispose of the meter and batteries according to local regulations for electronic waste, following the WEEE directive.
See more

Catalog excerpts

GlucoLab-1

132, Anyangcheondong-ro, Dongan-gu, Anyang-si I Lancing Device: GMMC Rm 1112, Ace Tower 9th Bldg., 130, Digital-ro, Geumcheon-gu, Seoul, Korea MREPI Global Medical Market Corporation S.L. Pare Industrial Ciutat de Carlet Mestral 20, 46240 Carlet, Valencia, Spain E-mail: [email protected] EIREPI ObelisS.A. E-Mail: [email protected]

 Open the catalog to page 1
GlucoLab-3

Dear GLUCOLABTM Auto-coding Blood Glucose Monitoring System Owner Test Principle Thank you for choosing the GLUCOLABTM Auto-coding Blood Glucose Monitoring System. This booklet has important information you must know about the GLUCOLABTM Auto-coding Blood Glucose Monitoring System. Please read it carefully. The enzyme glucose oxidase on the blood glucose test strip reads specifically with the blood glucse. The current generated is converted and displayed as blood glucose value. The GLUCOLABTM Auto-coding Blood Glucose Monitoring System is plasma-calibrated to allow easy comparison of results...

 Open the catalog to page 3
GlucoLab-4

Intended use of GLUCOLABTM Auto-coding Blood Glucose Test Meter Contents 1. Learning the System Intended use of Blood Glucose Test Meter GLUCOLABTM Auto-coding Blood Glucose Monitoring System Kit Contents GLUCOLABTM Auto-coding Blood Glucose Test Meter GLUCOLABTM Auto-coding Blood Glucose Test Meter Display GLUCOLABTM Auto-coding Blood Glucose Test Strip Information Setting the blood glucose test meter Auto-Coding Function Performing a Glucose control solution test The GLUCOLAB Auto-codingTM Blood Glucose Monitoring System is intended for in vitro diagnostic use only. GLUCOLAB Auto-codingTM Blood...

 Open the catalog to page 4
GlucoLab-5

GLUCOLABTM Auto-coding Blood Glucose Monitoring System KIT Contents GLUCOLABTM Auto-coding Blood Glucose Test Meter Blood glucose test strip Port: Insert the GLUCOLABTM Auto-coding blood glucose test strip here. Blood glucose test strip ejector Display Screen: Displays your test results, symbols and messages. Function Button: Powers the meter on/off, prompts memory data and acts as an enter button during setup and after tests. BLOOD GLUCOSE TEST METER For use with 1. GLUCOLAB Auto-coding Blood Glucose Test Meter 2. GLUCOLABTM Auto-coding Blood Glucose Test Strips 3. Lancing Device 4. Lancets...

 Open the catalog to page 5
GlucoLab-6

GLUCOLABTM Auto-coding Blood Glucose Test Meter Display Low Battery Warning Symbol User ID Symbol Strip Code Symbol Blood drop symbol for test Alarm Symbol Before Having a Meal After Having a Meal After Sports Activity After Taking Medication Temperature / Date Time / Test Result Amount Test Result Unit Symbol Control Solution Symbol R Average Test Result System Delete results GLUCOLABTM Auto-coding Blood Glucose Test Strip Information Storage and Handling Caution 1. Keep out of direct sunlight. 2. Store the GLUCOLABTM Auto-coding Blood Glucose Test Strip vials in a cool, dry place between 2-30°C(36-86℉)....

 Open the catalog to page 6
GlucoLab-7

GLUCOLABTM Auto-coding Blood Glucose Test Strip Information Limitations of Blood glucose measuring system : The blood glucose test Strips provide accurate results when the following constraints are observed : - Use the GLUCOLABTM Auto-coding blood glucose test strips with the GLUCOLABTM Auto-coding blood glucose test meter or GLUCOLABTM blood glucose test meter. - Use fresh capillary whole blood only. - Do not use neonate samples. - The blood glucose test strips are for single use only. Do not reuse. - Dehydration may lower test results. - Inaccurate results may occur when in shock, hypotensive,...

 Open the catalog to page 7
GlucoLab-8

Setting Your Blood Glucose Test Meter Temperature unit Number of days for average Press and release either ▲ or ▼ buttons to set ℉ or ℃. Enter button. After pressing and releasing either ▲ or ▼ buttons to set the number of days for average calculation (3 different possible), confirm with . Auto-Coding Function 1. GLUCOLABTM Auto-coding has automatic code recognition function. Alarm on/off After pressing and releasing either ▲ or ▼ buttons to turn the alarm on/off, confirm with . 2. It recognizes automatically the code number. This is a very convenient function preventing the inconvenience of...

 Open the catalog to page 8
GlucoLab-9

Performing a Glucose Control Solution Test The glucose control solution should be used when there is suspicion that the blood glucose test meter or the blood glucose test strips are not working properly. For example: if strips have been exposed to extreme conditions or if you drop the blood glucose test meter. Check the expiration date before performing a glucose control solution test. Do not used if expired. Once opened, solution expires after 3 months. The Glucose control solution should be used •Whenever you suspect the blood glucose test meter or blood glucose test strip is not functioning...

 Open the catalog to page 9
GlucoLab-10

Testing Your Blood - Preparation Collecting a Drop of Blood Before testing, be sure to read this section and blood glucose test strip package insert found in the blood glucose test strip box carefully, Make sure you have all the necessary items to begin testing: • GLUCOLABTM Auto-coding blood glucose test meter • GLUCOLABTM Auto-coding blood glucose test strip • Lancing Device • Sterile Lancets The lancing device is a convenient medical tool for collecting capillary blood samples for glucose monitoring or other tests which require one or two drops of blood. As a more advanced lancing device,...

 Open the catalog to page 10
GlucoLab-11

Collecting a Drop of Blood Collecting a Drop of Blood Disposing of your lancet 1. Unscrew the tip of the lancing device by turning it counter-clockwise while holding the base firmly. 2. With two fingers, pull out the lancet carrier and hold it in place. 3. While holding the lancet carrier, insert a new sterile lancet into the bottom of lancet carrier. 1. Push the needle into the protective cover. 2. Pull the lancet out and discard accordingly. Recommended Available Lancing Device INFOPIA®, ElementTM sterile Lancet is used with a Lanzo Lancing device. 12345 5. Put the tip of the lancing device...

 Open the catalog to page 11
GlucoLab-12

Testing Procedure Testing Procedure Correct Applying Blood Completely Filled Note : Inserting the blood glucose test strip in the wrong direction will turn the blood glucose test meter on, but you will be unable to test. Caution 1. If the code is not displayed after for a while, pull the blood glucose test strip out of the port, and re-start the procedure from the beginning. 2. If the code on the LCD display window and on the test vial does not match, try another new blood glucose test strip. If the mismatch persists, please contact your local representative for help. 3. If the blood glucose...

 Open the catalog to page 12

All OSANG Healthcare catalogs and technical brochures

  1. Gluconnect

    2  Pages

  2. SelexOn

    2  Pages

  3. LipidPro

    2  Pages

  4. Clover A1c

    2  Pages

  5. Finetest

    24  Pages

  6. Finetest AC

    24  Pages

  7. Healthpro

    24  Pages

  8. Element

    22  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.