TS Implant System
47Pages

{{requestButtons}}

Catalog excerpts

TS Implant System - 1

Osstem Implant 2016-17 Comprehensive Catalog Overall Planning/Editing PR Department Design Team Supervision Implant Lab, Marketing PM Production/Distribution Marketing & Planning Team Date of Publication 2016. Publisher Osstem Implant 8th FL, World Meridian II, 123, Gasan digital 2-ro, Geumcheon-gu, Seoul, Korea Phone +82.2.2016.7000 Fax +82.2.2016.7001 www.osstem.com INTRODUCTION CONTENTS TS SYSTEM REFERENCE

Open the catalog to page 1
TS Implant System - 6

ZioCera Angled Abutment Temporary Abutment Quick Temporary Abutment Multi Abutment Multi Angled Abutment Simple Mount Cover Screw Convertible Abutment Convertible Combination Cylinder Convertible Angled Cylinder Convertible GoldCast Cylinder Convertible Temporary Cylinder Healing Abutment Custom Healing Abutment Rigid Abutment Convertible Plastic Cylinder Convertible Pick-up Impression Coping Convertible Transfer Impression Coping Rigid Impression Coping Rigid Burn-out Cylinder Transfer Abutment Laboratory Screw Convertible Polishing Protector Stud Abutment Bite Index Fixture Pick-up...

Open the catalog to page 6
TS Implant System - 7

TSII SA Fixture TSII CA Fixture TSIII SA Fixture TSIII CA Fixture TSIII BA Fixture TSIII HA Fixture TSIV SA Fixture TSIV CA Fixture Simple Mount Cover Screw Healing Abutment Custom Healing Abutment PROSTHETIC FLOW DIAGRAM 1 Rigid Abutment Transfer Abutment PROSTHETIC FLOW DIAGRAM 2 Angled Abutment FreeForm ST Abutment GoldCast Abutment NP-Cast Abutment PROSTHETIC FLOW DIAGRAM 3 SmartFit Abutment Link Abutment (for Public / Cerec) Ziocera (Angled) Abutment Temporary Abutment (Quick) PROSTHETIC FLOW DIAGRAM 4 Multi (Angled) Abutment PROSTHETIC FLOW DIAGRAM 5 Convertible Abutment PROSTHETIC...

Open the catalog to page 7
TS Implant System - 8

�Submerged type implant with an internal hex and 11� tapered connection �Optimized screw thread design with the ideal SA surface �Straight body design allows easy insertion depth adjustments �Excellent initial stability in soft bone due to small threads in the upper section �Corkscrew threading with excellent self-threading effect �Recommended insertion torque: ※ Fixtures with a diameter of 4.5mm or more are recommended for the posterior area. NoMount fixture order code : fixture product code (ex : TS2S4010S) Pre-Mounted fixture (fixture + mount + cover screw) order code : B + fixture...

Open the catalog to page 8
TS Implant System - 9

�Submerged type implant with an internal hex and 11�tapered connection �Super-hydrophilic SA surface suspended in a calcium solution �Straight body design allows easy insertion depth adjustments �Excellent initial stability in soft bone due to small threads in the upper section �Corkscrew threading with excellent self-threading effect Ultra-wide �Ideal for an extracted tooth site in the posterior area, for immediate placement, or for replacing a failed implant �Apex is specifically design for excellent initial stability in an extracted tooth site �Recommended insertion torque: ≤40 Ncm ※...

Open the catalog to page 9
TS Implant System - 10

�Submerged type implant with an internal hex and 11� tapered connection �Optimized screw thread design with the ideal SA surface �Tapered body design with high initial stability �Excellent initial stability in soft bone due to the small thread on the upper part �Corkscrew threading with excellent self-threading effect �Excellent initial stability necessary for immediate loading, even in soft bone Extra short Narrow �A fixture that can be placed in tight spaces (narrow ridge) �Angle compensate is easy in the anterior area �Compatible with existing mini-international connection abutments...

Open the catalog to page 10
TS Implant System - 11

�Submerged type implant with an internal hex and 11�tapered connection �Super-hydrophilic SA surface suspended in a calcium solution �Tapered body design with high initial stability �Excellent initial stability in soft bone due to the small thread on the upper part �Corkscrew threading with excellent self-threading effect �Excellent initial stability necessary for immediate loading, even in soft bone Extra short Narrow �A fixture that can be placed in tight spaces (narrow ridge) �Angle compensate is easy in the anterior area �Compatible with existing mini-international connection abutments...

Open the catalog to page 11
TS Implant System - 12

�Submerged type implant with an internal hex and 11�tapered connection �Super-hydrophilic surface enhances the rapid formation of blood clots �SA surface coated with premium low crystalline nano-HA �Bio-absorbable coating with no risk of fracturing or flaking off �Tapered body design with high initial stability �Excellent initial stability in soft bone due to the small thread on the upper part �Corkscrew threading with excellent self-threading effect �Excellent initial stability necessary for immediate loading, even in soft bone �Recommended insertion torque: ≤40 Ncm ※ Fixtures with a...

Open the catalog to page 12
TS Implant System - 13

�Submerged type implant with an internal hex and 11�tapered connection �Premium high-crystalline HA-coated surface �Tapered body design with high initial stability �Excellent initial stability in soft bone due to the small thread on the upper part �Corkscrew threading with excellent self-threading effect �Excellent initial stability necessary for immediate loading, even in soft bone �Recommended insertion torque: ≤40 Ncm ※ Fixtures with a diameter of 4.5mm or more are recommended for the posterior area ※ Recommended to use carefully, as the high-crystalline HA coating has a risk of...

Open the catalog to page 13
TS Implant System - 14

Fixture Ultra-wide �Submerged type implant with an internal hex and 11�tapered connection �Optimized screw thread design with the ideal SA surface �Designed specifically for the maxillary sinus and soft bone �Excellent initial stability in soft bone due to the small thread on the upper �Corkscrew threading with excellent self-threading effect �Aggressive apex design allows placement even in a ∅2.0 or ∅3.0mm osteotomy in D4 bone Ultra-wide �Ideal for an extracted tooth site in the posterior area, for immediate placement, or for replacing a failed implant �Apex is specifically design for...

Open the catalog to page 14
TS Implant System - 15

Fixture Ultra-wide �Submerged type implant with an internal hex and 11�tapered connection �Designed specifically for the maxillary sinus and soft bone �Excellent initial stability in soft bone due to the small thread on the upper part �Super-hydrophilic SA surface suspended in a calcium solution �Corkscrew threading with excellent self-threading effect �Aggressive apex design allows placement even in a ∅2.0 or ∅3.0mm osteotomy in D4 bone Ultra-wide �Ideal for an extracted tooth site in the posterior area, for immediate placement, or for replacing a failed implant �Apex is specifically...

Open the catalog to page 15

All Osstem Implant France catalogs and technical brochures