Non-invasive Cardiac Output
6Pages

{{requestButtons}}

Catalog excerpts

Non-invasive Cardiac Output - 1

OSYPKA MEDICAL Noninvasive Cardiac Output E,ectrical Cardiometry™ AESCULON' Window to the Circulation®

Open the catalog to page 1
Non-invasive Cardiac Output - 2

Electrical Cardiometry™ (EC™) Electrical Cardiometry™ is a method for the non-invasive determination of stroke volume (SV), cardiac output (CO), and other hemodynamic parameters in adults, children, and neonates. Electrical Cardiometry has been validated against “gold standard” methods such as thermodilution and is a proprietary method patented by Osypka Medical. Sensor located at the left side of neck and thorax iSense Single Patient EC Sensors How it works The placement of four skin sensors on the neck and left side of the thorax allow for the continuous measurement of the changes of...

Open the catalog to page 2
Non-invasive Cardiac Output - 3

Advanced, Non-Invasive Hemodynamic Monitoring: Blood pressure, heart rate and other vital signs typically available to clinicians do not give a complete picture of a patient's hemodynamics. Guiding therapy by traditional parameters makes it very difficult to decide whether volume, inotropes, or vasopressors would be best for the patient. With the ICON and AESCULON, the user gets a complete picture of the patient hemodynamics using a method that is quick, easy, safe, non Invasive and accurate. The parameters provided by EC fill in the blanks of traditional monitoring, helping physicians...

Open the catalog to page 3
Non-invasive Cardiac Output - 4

Window to the Circulation® AESCULON® Parameters SV/SI Stroke Volume / Stroke Index CO/CI Cardiac Output /Cardiac Index Vascular System SSVR / SSVRI Non-invasive Blood Pressure Systemic Vascular Resistance/ SVR-Index based on input of Central Venous Pressure (CVP) Stroke System Vascular Resistance/ SSVR-Index ICON™ Index of Contractility VIC™ Variation of Index of Contractility LCW / LCWI Left Cardiac Work based on input of Wedge Pressure (PAOP) LSW / LSWI Left Stroke Work STR Systolic Time Ratio (PEP/LVET) CPI Cardiac Performance Index Fluid Status TFC SVV FTc...

Open the catalog to page 4
Non-invasive Cardiac Output - 5

Blood Flow SV/SI HR CO/CI Stroke Volume / Stroke Index Heart Rate Cardiac Output /Cardiac Index SVR /SVRI Systemic Vascular Resistance/ SVR-Index based on input of Blood Pressure (BP) and Central Venous Pressure (CVP) ICON™ Index of Contractility VIC™ Variation of Index of Contractility STR Systolic Time Ratio (PEP/LVET) CPI Cardiac Performance Index TFC Thoracic Fluid Content SVV Stroke Volume Variation FTC Corrected Flow Time based on input of Hemoglobin and SpO2 1. Attach Sensors 2. Press SETUP 3. Enter Patient Data 4. Press MEASURE to start ICON® Features • 3.5"...

Open the catalog to page 5
Non-invasive Cardiac Output - 6

Technical Data Measurement Method Electrical Cardiometry (EC) Electrical Velocimetry (Advanced Bio-Impedance) Electrical Cardiometry (EC) Electrical Velocimetry (Advanced Bio-Impedance) Non-invasive Blood Pressure (NIBP) Oscillatoric systolic: 40 mm Hg ... 260 mm Hg diastolic: 25 mm Hg ... 200 mm Hg Oxygen Saturation (SpO2) optional Power Consumtion Internal Battery Enclosure Dimensions: height x width x depth According to EC-Directive US. Regulatory Class Protection Type Standard Compliance Class IIa Class II Class 1 equipment (Typ BF) IEC 60601-1, IEC 60601-1-2 and more Class IIa Class...

Open the catalog to page 6