PACE 101 H / PACE 203 H / PACE 300 03 PACE 101 H / PACE 203 H / PACE 300 External Cardiac Pacemakers +++ Externer Demand-Herzschrittmacher External Demand Pacemaker Externer Zweikammer-Herzschrittmacher her External Dual Chamber Pacemaker Externer Dreikammer-Herzschrittmacher External Triple Chamber Pacemaker
Open the catalog to page 102 PACE 101 H / PACE 203 H / PACE 300 PACE 203 H Handliches Design, einfache und schnelle Bedienung durch Dreh- und Druckknöpfe / Handy design, simple and quick handling by control and press button Terminals for patient Cables and Leads Pacing Mode Indicator Basic Rate Basic Rate A-Sensitivity (AAI A00, DDD->DVI) Atrial Sensitivity Atrial Stimulation Amplitude Ventricular Stimulation Amplitude Ventricular Sensitivity Dedicated function keys: Emergency, Lock/Unlock, Pause Dedicated function keys: On and Off 4 Softkeys: Selection of primary mode (DDD, VVI, AAI, VDD) PAUSE-Funktion /...
Open the catalog to page 2PACE 101 H / PACE 203 H / PACE 300 03 Technische Daten: Technical Data: • Modi: DDD, VDD, D00, VVI, V00, AAI, AAT, A00, DVI, DAI, VAT, DDD+AT, DAT • Grundfrequenz 30 …220 ppm • Obere Frequenzbegrenzung 80 … 230 ppm • Overdrive-Stimulation (atrial) 70 … 1000 ppm • Ventrikuläres Rapid Pacing 180 … 220 ppm • Stimulationsamplituden 0,1 … 18 V • Impulsdauer 0,05 … 1,5 ms • Empfindlichkeit atrial 0,2 … 20 mV, ∞ ventrikulär 1,0 … 20 mV, ∞ • Refraktärzeit atrial 250 … 400 ms PVARP 100 … 500 ms ventrikulär 200 … 500 ms • AV-Delay 5 … 400 ms • Modes: DDD, VDD, D00, VVI, V00, AAI, AAT, A00, DVI, DAI,...
Open the catalog to page 304 PACE 101 H / PACE 203 H / PACE 300 Besondere Eigenschaften Special Features (zusatzlich zu den Funktionen des PACE 203H): (additional to the features of PACE 203H): • Variable setting of VV-Deiay (pacing threshold as well as sensitivity) • Individuelle Einstellung des VV-Delays (Stimulations-Amplitude sowie Wahrnehmung) V-V Delay Einstellung zur temporaren Biventrikularen Stimulation (CRT) zur post-operativen hamodynamischen Optimierung Herzchirurgischer Patienten* Setting of the V-V Delay for temporary biventricular stimulation (CRT) to optimize post-operative hemodynamics of...
Open the catalog to page 4All OSYPKA catalogs and technical brochures
-
TB-FX / TB-FX J
1 Pages
-
BIPOLAR Pacing Catheter
1 Pages
-
OSYPKA Snare Catheter
2 Pages
-
HAT 500® -System
4 Pages
-
Adelante® & D-EB-P
4 Pages
-
End Caps
1 Pages
-
Permanent Adapters
2 Pages
-
VACS® II & VACS® III
4 Pages
-
TME
4 Pages
-
SIRIUS®
4 Pages
-
FINDER®
4 Pages
-
CERABLATE flutter®
4 Pages
-
VACS® II / VACS® III
4 Pages
-
HAT 500®-System
4 Pages
-
LASSOS® / CATCHER®
2 Pages
-
SIRIUS flutter®
2 Pages
-
FINDER pure®
4 Pages
-
CERABLATE cool®
4 Pages
-
CERABLATE® easy / easy TC
4 Pages