Catalog InterVacTechnology 2023
20Pages

{{requestButtons}}

Catalog excerpts

Catalog InterVacTechnology 2023 - 1

VACUUM BLOOD COLLECTION SYSTEM

Open the catalog to page 1
Catalog InterVacTechnology 2023 - 2

NORWAY SWEDEN UNITED KINGDOM GERMANY CZECH REPUBLIC AUSTRIA SWITZERLAND InterVacTechnology OÜ is the unique high-technology manufacturer of the vacuum blood collection system Lind-Vac® in the Baltic states. The Lind-Vac® vacuum blood collection system was introduced into market in 2011. The system has been designed for quick, safe, correct and hygenic blood collection. We offer a complete range of blood collection tubes available in different sizes and with appropriate additives. Also we provide a wide range of Lind-Vac® needles and holders to perform a total safety of vacuum blood...

Open the catalog to page 2
Catalog InterVacTechnology 2023 - 3

Free Sales certificate (CE mark)      

Open the catalog to page 3
Catalog InterVacTechnology 2023 - 4

Clinical chemistry, serology, immunology tests of blood serum. No additive Clot activator Clinical chemistry, serology, immunology tests of blood serum. Clinical chemistry, serology, immunology tests of blood serum. Express clinical chemistry tests of blood serum. Express clinical chemistry tests of blood serum. Hematological and molecular genetic tests. Blood sedimentation test (ESR). Hemostasis Diagnostics (Coagulation). Clinical chemistry, immunology, toxicology tests of blood plasma. Glucose level, lactate, glycosylated hemoglobin. Glucose for the diagnosis of gestational diabetes...

Open the catalog to page 4
Catalog InterVacTechnology 2023 - 5

Description of base tubes Vacuum tube with no additive Tubes are used to tak (blood, urine, cerebr Usage: resear chemistry, serology, immunology. Can be used as primary tubes for tests, storage and transportation of biomaterials. Specimen: Clotting time: 60 minutes. Conditions of centrifugation: 1300 g for 10 minutes. Before centrifuging the tubes with serum it is necessary to wait until blood clotting. Color code: Red Vacuum tube with clot activator Serum Separation tubes are covered with clot activator powder to accelerate blood coagulation. Silica (clot activator) is used as the...

Open the catalog to page 5
Catalog InterVacTechnology 2023 - 6

Description of base tubes Vacuum tube with clot activator & gel As the activator it is used silica dioxide and biologically Gel provides the separation of serum and clot up to 48 hours without re- centrifugation. Gel is the special material intended for formation of barrier between cellular components of blood and serum during centrifugation. The steady barrier is formed within 5 minutes after There is added gel silica dioxide in the test tube providing a complete clotting during the 30 min. After capturing of blood sample into the vacuum tube with gel, it should be mixed 5-6 times. Usage:...

Open the catalog to page 6
Catalog InterVacTechnology 2023 - 7

Description of base tubes Vacuum tube with thrombin Thrombin is used for rapid laboratory tests. An inside surface of a tube is processed by a complex clots forming. After the process of centrifuging it allows to get a sample of serum for further tests. Using thrombin blood collection tubes it is possible than using no additive tubes. Usage: rapid tests of the serum in Clinic Chemistry, Immunology, Serology. Specimen: blood serum. Clotting time: 3-5 minutes. Centrifugation conditions: 1300 g during 10 minutes. Before centrifuging of tubes with the serum it is important to wait until full...

Open the catalog to page 7
Catalog InterVacTechnology 2023 - 8

Description of base tubes Vacuum tube for Hematology (potassium EDTA) Additive: potassium salt of EDTA (ethylenediaminetetraacetate). In accordance with international practice it is possible to use three options of EDTA: - EDTA K3; - EDTA K2; - EDTA Na2 In vacuum tubes anticoagulant is added in powder EDTA K2 or EDTA K3 solution, concentration reaches 1.8 mg/ml After taking blood into the tube it should be mixed by turning 6-8 times. Lack of mixing can also cause platelet aggregation, coagulation or formation of micro clots. Specimen: whole blood or plasma (Gel tubes) with Gel. Color code:...

Open the catalog to page 8
Catalog InterVacTechnology 2023 - 9

Description of base tubes Vacuum tube for coagulation (citrate) Additive: to research the hemostatic system there is used trisodium citrate liquid concentr The volume ratio of blood and sodium citr ate is an anticoagulant for collection of venous blood to research coagulation properties of blood. Anti-coagulative properties of citrate are shown in complex emoval them from blood. REF Sodium citrate 3,8% Size (mm) Volume (ml) Usage: to research the hemostatic system. Sodium citrate 3,2% Size (mm) Volume (ml) Specimen: plasma. Immediately after taking the blood into the tube with citrate it...

Open the catalog to page 9
Catalog InterVacTechnology 2023 - 10

Description of base tubes Additive: Lithium or Sodium Heparin Vacuum tube for plasma separation (lithium / sodium heparin) Heparin is a natural anticoagulant which presents in any healthy body. Heparin is used to take the plasma for chemical, immunology and toxicology tests. Plasma is freed from the cells by the centrifugation. Clotting of blood is prevented by the addition of an anticoagulant directly after the taking of blood. For this purpose, the lithium or sodium heparin is added in this tube. Advantages in comparison with serum: The bigger volume of material in the same volume of...

Open the catalog to page 10
Catalog InterVacTechnology 2023 - 11

Description of base tubes Vacuum tube for glucose determination Additive: test tubes contain anticoagulant and the glucose stabilizer. TA, K2-EDTA, EDT heparin can be used as an anticoagulant. Additives: Potassium o T K2-EDT EDT test tube allows to pre pr sample of blood. into the eep its level in the taken Specimen: plasma. V can cause hemolysis. Glucose tubes Size (mm) Volume (ml) After drawing the blood into the tube it should be mixed by xalate are exposed to hemolysis much more than other they must be mixed with extreme caution. Conditions of centrifugation: Centrifugation should be...

Open the catalog to page 11
Catalog InterVacTechnology 2023 - 12

Description of base tubes Vacuum tube for analysis of free extracellular DNA A vacuum tube is designed to collect venous blood for the subsequent analysis of free extracellular DNA. This kind of analysis is necessary for examination of DNA fragments. These can be, for example, fragments of fetal DNA in the blood of the mother. It’s analysis lets determine the gender of the child at the early stages of development and identify some hereditary multations. Also among free extracellular DNA there may be DNA fragments with somatic mutations resulting from carcinogenesis. Analysis of these...

Open the catalog to page 12