DATASHEET ILINE F

DATASHEET ILINE F

DATASHEET ILINE F

Product catalog summary
Technology Overview
Ovizio's platform utilizes patented Differential Digital Holographic Microscopy, enabling real-time, label-free monitoring of suspension cell bioreactors. This technology allows for 3D numerical reconstruction of objects by interfering a scattered light beam with a reference beam on a CCD camera. The iLine F measures holographic signatures of cells to compute cell counts and reports cell density and viability online.

Device Features
The iLine F is designed for direct monitoring of suspension cell bioreactors, featuring real-time cell density and viability monitoring. It connects to bioreactors via the BioConnect disposable fluidics system. The software captures real-time 3D images and quantitative data for automatic cell counting. The device is adaptable to different cell sizes with a typical magnification of 20X.

Measurements and Applications
  • Cell count
  • Cell viability
  • Cell morphology
  • Cell clusters
The technology supports the entire bioreactor cycle, allowing operators to track cell density and viability in real-time, reducing contamination risks and improving harvest time predictions. It is effective across a wide range of cell densities.

OsOne Software
The iLine F is paired with the OsOne software, designed for ease of use and comprehensive data analysis. It simplifies the user experience and provides tools for thorough data investigation.

Operational Process
  1. Assemble
  2. Autoclave and connect pump
  3. Insert in iLine F
The iLine F uses a sterile closed-loop fluidics system to pump cells through the imaging device, capturing holograms for continuous analysis of cell density and viability.

Benefits
  • On-line bioreactor monitoring
  • Viable cell density measurement
  • Label-free and non-invasive
  • Reduced operational costs by up to 50%
  • No sampling or sample preparation required
  • Environmentally friendly

Contact Information
Ovizio Imaging Systems, Rue du Bourdon 100, B-1180 Brussels, Belgium. Phone: +32 2 600 50 90, Email: [email protected]

Global Partner
Applikon Biotechnology BV, Heertjeslaan 2, 2629 JG Delft, The Netherlands. Phone: +31 10 208 35 55, Email: [email protected]
See more

Catalog excerpts

DATASHEET ILINE F-1

ON-­‐LINE QUANTITATIVE CELL IMAGING ANALYSER TECHNOLOGY Ovizio’s platform is based on patented “Differential Digital Holographic Microscopy”. This unique technology brings real-­‐time label-­‐free monitoring to suspension cell bioreactors. In Digital Holography, the scattered light beam from an illuminated object interferes with a reference beam on a CCD camera allowing for a 3D numerical reconstruction of the object. Differential Digital Holography is an evolution of this base technology that brings increased stability and an important size reduction of the instruments. Digital Holography can construct intensity images; quantitative phase images and 3D phase images covering the shape and density of an object in a volume. The phase image is equivalent to the optical thickness of the sample. Images of cells captured in a hologram can be refocused after acquisition. The iLine F measures the specific holographic signature of each cell within the field of view and computes a cell count based on a sequence of holograms. The platform reports cell density and cell viability per measurement sequence (on-­‐line). Ovizio’s instrument is designed with bioreactors in mind. The technology can track a bioreactor run and counts cell viability from very low to high cell concentrations. This device has been developed for direct monitoring of suspension cell bioreactors. The device has built-­‐in functionality to monitor cell density and cell viability in real-­‐time. The iLine F can be connected to a bioreactor via an innovative disposable fluidics system, BioConnect. The advanced, easy to use software captures real time 3D images and quantitative data allowing for automatic cell counting and other specific measurements. The total magnification is typically 20 X but can be adapted to fit the size of the cells to be observed. MEASUREMENTS • • • • Cell count Cell viability Cell m orphology Cell clusters The technology can be used throughout the bioreactor cycle and will allow the operator to track cell density and cell viability in real-­‐time eliminating the need for sampling and reducing the risk of contamination. Tracking cell growth continuously allows for more accurate prediction of the optimum harvest times. The platform is designed to cope with very low cell densities and very high densities. Quantitative imaging as a new Process Analytical Technology (PAT) is applied to on-­‐line bioreactor monitoring and improves process knowledge, quality and productivity in R&D, Pilot and Production. FEATURES ① On-­‐line bioreactor monitoring ② Viable cell density measurement ③ Label-­‐free ④ Reduced operational costs up to 50% ⑤ No sampling, no sample preparation ⑥ Non-­‐invasive ⑦ Environmental-­‐friendly

 Open the catalog to page 1
DATASHEET ILINE F-2

The iLine F is delivered in combination with the easy to operate ‘OsOne’ software package. This workflow driven application is intended to get beyond the burden of current cumbersome life sciences instrument applications and is focused on giving the user a straightforward experience. OsOne allows the user to focus on the result of a measurement while offering all the tools required for a thorough investigation of the underlying data. CELL DENSITY AND VIABILITY Cell...