Catalog excerpts

iXon EMCCD - 1

an Oxford Instruments company Featuring the NEW iXon Life models

Open the catalog to page 1
iXon EMCCD - 2

The Industry’s Highest Performance Scientific EMCCD Cameras Andor Technology pioneered the world’s first scientific Electron Multiplying CCD (EMCCD) cameras, shipping the initial cameras back in 2000 and winning the Photonics 2000 Andor shipped first EMCCD cameras • Pioneering EMCCD cameras Circle of Excellence award. At • Photonics Circle of Excellence Award that time, Andor coined the name ‘Electron Multiplying 2001 iXon CCD (EMCCD)’, which has • Flagship high-end EMCCD camera platform • First to introduce back-illuminated sensors been adopted right across this • Deepest cooling and...

Open the catalog to page 2
iXon EMCCD - 3

an Oxford Instruments company The EMCCD Advantage The iXon Platforms Ultimate sensitivity with super fast speeds iXon Ultra Driving the absolute best from EMCCD technology The market leading EMCCD camera, Andor's iXon Ultra has been long recognized as the highest performance, most versatile solution for the most demanding of light starved applications. Available for both physical and life science applications, iXon Ultra delivers unbeatable flexibility and functionality, offering market leading TE cooling, ‘2-in-1’ EMCCD and CCD readout modes and a host off other high end functionality....

Open the catalog to page 3
iXon EMCCD - 4

an Oxford Instruments company iXon 888 ModelsField of View and Sensitivity... now 3x faster! Features and Benefits 13.3 x 13.3 mm sensor Largest field of view EMCCD available Single Photon Sensitive and > 95% QE Optimal SNR in light starved applications such as single molecule detection and quantum physics Overclocked to 30 MHz readout Follow dynamic changing processes. Crop Mode Continuous imaging with fastest possible frame rate from centrally positioned ROIs. Highly enabling for live cell super-resolution and much more (e.g. 251 fps with 256 x 256 ROI). TE cooling to -95°C (deepest...

Open the catalog to page 4
iXon EMCCD - 5

an Oxford Instruments company iXon 897 ModelsUltimate sensitivity... supercharged! Available on iXon Ultra and iXon Life platforms, the iXon 897 models take the popular back-illuminated 512 x 512 frame transfer sensor and overclock readout to 17 MHz, pushing speed performance to an outstanding 56 fps (full frame), whilst maintaining quantitative stability throughout. Ultimate sensitivity is also attained through deep thermoelectric cooling down to -95°C and industry-lowest clock induced charge noise. The significant speed boost offered in the iXon Ultra 897 facilitates a new level of...

Open the catalog to page 5
iXon EMCCD - 6

an Oxford Instruments company Performance & Innovations Industry Fastest Frame Rate Optically Centered Crop Mode: Enabling Live Cell Super-Resolution Pushing Frame Rates with Crop Mode Maximum frame rate performance in EMCCDs is a function of two parameters; (1) Pixel Readout Speed (horizontal); (2) Vertical Clock speed. The former dictates how rapidly charge is pushed horizontally through the EM gain register and the remaining readout electronics, while the latter dictates the speed at which charge is vertically shifted down through both the exposed sensor area and masked frame transfer...

Open the catalog to page 6
iXon EMCCD - 7

Performance & Innovations EX2 Technology - Extended QE from Dual AR sensor coating (iXon Ultra) iXon Ultra models are now available with a new Dual Anti-Reflection coating applied to the back-illuminated sensor, affording a significant enhancement of the Quantum Efficiency performance. iXon Ultra models are now available with a new Fringe Suppression property in the sensor design, reducing spatial etaloning effects that can arise through monochromatic imaging in the Near Infra-Red (NIR) wavelength range. manufacturer e2v. The net effect is to offer significantly improved sensitivity in both...

Open the catalog to page 7
iXon EMCCD - 8

Performance & Innovations Deep Thermoelectric Cooling Spurious Noise Filter Single thermal electrons are amplified by the EMCCD gain mechanism. Deep vacuum TE cooling is critical to optimize the sensitivity performance of EMCCD sensors, otherwise the raw sensitivity will be compromised, even under conditions of short exposures. It can still be desirable to optionally filter the remaining spurious noise (Clock-Induced Charge or photons) to give as ‘black’ a background as possible, eradicating any remaining ‘salt and pepper’ noise. It is important to utilize noise selection and filter...

Open the catalog to page 8
iXon EMCCD - 9

Performance & Innovations Vacuum The iXon is well regulated in terms of both Baseline (bias offset) rigidity and superior EM gain stability, lending for enhanced quantitative reliability throughout and between measurements. Baseline Clamp OFF Window (Anti-reflection Coated) Heat Removal EM Gain Stability Mean ROI signal / ADU Andor’s proprietary UltraVac process has a proven track record of field reliability, accumulated over more than 15 years of shipping high-end vacuum cameras. UltraVac also enables use of only one input window, improving photon-throughput by 8%. Permanent, All-Metal...

Open the catalog to page 9
iXon EMCCD - 10

Performance & Innovations Software Solutions ‘2 in 1’ Performance - EMCCD and CCD (iXon Ultra) iXon Ultra 888 and 897 models offer ‘2 in 1’ performance flexibility, in terms of operating as a single photon EMCCD or a low noise conventional CCD, readily user selectable through software selection. Such versatility is attractive in laboratories that can require the camera to operate in low light conditions under both fast and slow frame rates. In photon starved applications, choosing the EMCCD amplifier usually yields better signal to noise ratio when under faster frame rates conditions (> 1...

Open the catalog to page 10
iXon EMCCD - 11

Application & Technical Notes Extensive Imaging Portfolio The Andor Imaging Range Andor’s high-performance EMCCD cameras have been the technology favorite of the vast majority of EMCCD-enabled laboratories across the globe. Have you found what you are looking for? As an alternative to the iXon series, Andor offers an extensive portfolio of high performance low light imaging camera technologies. iKon CCD Deep cooled, low noise CCD iXon EMCCD High performance EMCCD platform Single photon sensitive and back-illuminated Industry fastest frame rates ‘PV Inspector’ model (Optimized for EL / PL...

Open the catalog to page 11

All Oxford Instruments catalogs and technical brochures

  1. Microstat™

    8 Pages

  2. ZYLA-5.5

    12 Pages

  3. Solis I

    6 Pages

  4. iXon Ultra 897

    13 Pages

  5. Mosaic

    6 Pages

  6. iXon Ultra 888

    12 Pages

  7. SpectromagPT

    2 Pages

  8. Heliox™

    2 Pages

  9. Triton™XL

    2 Pages

  10. Triton™

    2 Pages

  11. MQC

    8 Pages

  12. Solis 64

    6 Pages