NRFit ®

NRFit ®

NRFit ®

Product catalog summary
Introduction to NRFit Standard:
The document introduces the NRFit standard, which is part of the ISO 80369 series issued in 2016 to prevent incorrect connections and injections. NRFit, specifically ISO 80369-6, is designed for neuraxial procedures, replacing the LUER standard with a new, incompatible connection.

Key Changes with NRFit:
  • NRFit connectors are 20% smaller and 3 mm longer than LUER connectors, with an additional outer cone.
  • Limited compatibility to neuraxial and major regional anesthesia applications.
  • Color-coded in yellow for easy identification and to avoid misconnections.

Product and Service Offerings:
PAJUNK® offers a comprehensive range of products for regional anesthesia, including spinal, epidural, and combined spinal-epidural anesthesia, nerve blocks, lumbar puncture, and wound infiltration, all compliant with the NRFit standard.

Support for Transition:
  • PAJUNK® provides counseling for planning, partnering, and execution of the transition to NRFit.
  • Offers standard and customized NRFit sets to facilitate the transition.
  • Assistance in procurement management, storage, and medical application training.

Product Range:
  • Neuraxial Anesthesia: Includes Sprotte Needle, EpiSpin Sets, and EpiLong II Sets.
  • Nerve Blocks: SonoPlex® II and SonoTAP® II for single and continuous techniques.
  • Lumbar Puncture: SPROTTE® Needle and accessories.
  • Wound Infiltration: FuserPump and InfiltraLong Sets.

Contact Information:
Details for PAJUNK® offices in Germany, USA, UK, and Switzerland are provided for further inquiries and support.
See more

Catalog excerpts

NRFit ® -1

REGIONAL ANESTHESIA Products & Services for Regional Anesthesia Connectors acc to ISO 80369-6

 Open the catalog to page 1
NRFit ® -2

NRFit ® – The New Standard for Regional Anesthesia In order to avoid the risk of incorrect connections and injections in the future, the ISO 80369-series of standards was issued in 2016. The new ISO norm replaces the overarching LUER standard and defines a separate, incompatible connection for each of the five application areas within the standard series: 80369-2 for Breathing Systems and Driving Gases, 80369-3 (ENFit ®) for Enteral and Gastric, 80369-5 for Limb Cuff Inflation, 80369-6 (NRFit ®) for Neuraxial procedures and 80369-7 (LUER) for Intravenous applications. As the leading manufacturer...

 Open the catalog to page 2
NRFit ® -3

The PAJUNK® All-Round Service for a Successful Conversion Ready to use: Standard and Customised NRFit Sets To make the LUER to NRFit transition as easy as possible, Pajunk offers complete standard sets with additional NRFit components (syringes, draw-up neeldes, straws, etc.) as well as customised set options which allow for full customisation and flexibility. No matter which NRFit set option you prefer, we will find the right configuration for your individual application to support your needs and the existing facility processes. Identification: Clear Labelling & Product Identification The yellow...

 Open the catalog to page 3
NRFit ® -4

NEURAXIAL ANESTHESIA Spinal Anesthesia SPROTTE® Sets & IntraLong Catheter Sets Epidural Anesthesia EpiLong II & EpiLong II Soft Sets Combined Spinal Epidural Anesthesia (CSE) EpiSpin Sets

 Open the catalog to page 4
NRFit ® -5

NERVE BLOCKS Single Shot Technique Continuous Technique PlexoLong NanoLine® SonoLong Echo

 Open the catalog to page 5
NRFit ® -6

LUMBAR PUNCTURE Lumbar Puncture WOUND INFILTRATION Continuous Wound Infiltration FuserPump & InfiltraLong Sets

 Open the catalog to page 6
NRFit ® -7

ACCESSORIESSyringe Pumps Connections Pumps ■tel Spike (vented) Spike (vented) Additional NRFit Accessories % ^ . I,, *Not all products are registered andapproved for sale in all countries orregions. Indications of use may also varyby country and region. Fit is a registered tra^iroii of GEDSA used Mth fheir permission. please contactyour country representative for productavailability and information. Productimages are for reference only Filter Straw Filter Needle

 Open the catalog to page 7
NRFit ® -8

PAJUNK® GmbH Medizintechnologie International Sales PAJUNK® Medical Produkte GmbH Central Europe PajunkstraOe 2 78187 Geisingen, Germany Tel.: +49 7704 8008-0 Fax: +49 7704 8008-150 [email protected] pajunk.de & pajunk.eu PAJUNK® Swiss AG Switzerland Neuhofstrasse 5A 6340 Baar, Switzerland Tel.: +41 417 609 627 PAJUNK® Medical System L.P. United States of America 45 75 Marconi Drive Alpharetta, GA 30005, USA Tel.: +1 888 972 5865 Fax: +1 678 514 3388 [email protected] pajunkusa.com PAJUNK® UK Medical Products Ltd United Kingdom Goldcrest Way, Newburn Riverside Newcastle upon Tyne, NE15...

 Open the catalog to page 8

All PAJUNK® Medical Produkte GmbH catalogs and technical brochures

  1. Pain Management

    13  Pages

  2. Nerve Blocks

    19  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.