Imagin
1 /8Pages

Imagin

Imagin
1 /8Pages

Catalog excerpts

Imagin-1

Advanced Digital Radiotherapy Simulator

 Open the catalog to page 1
Imagin-2

“Healthcare has evolved with time with advancements and breakthroughs in technology. With increasing number of cancer cases across the world, there are major initiatives taken by healthcare professionals to eradicate cancer. Radiation therapy has played a key role in treatment of cancer. Technology has improved, and the delivery of radiation has become more precise, and radiation oncologist are now able to deliver required doses of radiation more safely. This has given radiation an even bigger role in cancer care” A new era of Simulation begins- Imagin Everyday Effective simulation and verication...

 Open the catalog to page 2
Imagin-3

BROADEN YOUR APPLICATIONS Now, simulate for all your treatment units With increasing number of treatment units in a Radiation Oncology department, it becomes essential for a radiotherapy simulator to be integrated with all the treatment units to increase throughput. IMAGIN can shake hands with any treatment machine, be it a cobalt platform or a linear accelerator. With a variable FAD and a state-ofthe-art indexed treatment planning couch, IMAGIN simulates and veries with sub millimetre accuracy for every treatment machine. IMAGIN’s wide application allows Brachytherapy planning to be performed...

 Open the catalog to page 3
Imagin-4

REDEFINING IMAGE CLARITY Simulate with clarity and confidence Equipped with a large at panel detector, IMAGIN is capable of imaging with pixel pitch of 139 microns and a resolution of 3K x 3K. With Movement in vertical, longitudinal and transverse direction, the detector is at your command. The images obtained with IMAGIN are free from artefacts and noise, thereby improving the overall image quality. With kV and mA range up to 150kV and 500mA respectively, IMAGIN helps in capturing images with high spatial resolution and detailed volume images that enables the clinicians to delineate targets...

 Open the catalog to page 4
Imagin-5

STREAMLINING YOUR WORKFLOW Improve your workflow with “KRYSTAL” Patient Set-Up DICOM Server Image Acquired Delineating Target Manual Registration Couch Shift Corrections The images obtained on IMAGIN assists the clinicians in isolating and segmenting the tumor. It also gives clinicians the sense of condence in planning and verifying the treatment plan. The system comes with a high storage capacity and is DICOM compatible.

 Open the catalog to page 5
Imagin-6

Expand your clinical capabilities with CBCT CBCT on IMAGIN can be performed for better spatial resolution, low contrast imaging and visualizing soft tissues with a thinner slice thickness of 0.5mm. The 280-degree rotation on IMAGIN aids to capture images at required angles and reconstruct the images with a eld size up to 25.6x25.6x25.6cm to clearly visualize the deep seated tumours. With faster acquisition and reconstruction within 60 seconds, IMAGIN improves the overall patient throughput and clinical efciency. Patient Set-Up VERIFICATION CBCT Volume Reconstructing CBCT Assuring Safety at...

 Open the catalog to page 6
Imagin-7

IMAGIN AT A GLANCE Simulation and Verification made easy Higher reproducibility with indexed treatment planning couch Simulation and verication for any treatment unit with variable FAD Store, retrieve, view and exhange images anywhere with DICOM Precise dose delivery for the anatomical region of interest Noise-free high resolution images with large Flat Panel Detector Low dose CBCT for a larger eld size providing Volumteric data to improve set up accuracy Advanced Imaging Technology to perform Radiography and Fluoroscopy with conde

 Open the catalog to page 7
Imagin-8

[email protected] www.panaceamedical.com C Panacea Medical Technologies Pvt. Ltd. All Rights Reserved CPS201 Specications are subject to change without any prior notications, Version

 Open the catalog to page 8

All Panacea Medical Technologies catalogs and technical brochures

  1. BHABHATRON 3i

    8  Pages

  2. SIDDHARTH II

    7  Pages

  3. Bahbhatron ll

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.