Overview: The document provides detailed information on cardiomyocyte isolation systems designed for use with small rodent hearts, specifically from mice to small rabbits. Two main systems are discussed: the PSCI Perfusion System and the EasyCell Basic System.
PSCI Perfusion System:
  • Designed for pharmacology labs requiring high-yield viability in cardiomyocyte assays.
  • Features dual perfusion pathways to separate clearing buffer from collagenase, ensuring minimal solution mixing.
  • Includes a solid-state perfusion circuit for thermal stability and laminar flow, with bubble traps to prevent air emboli.
  • Compatible with ethanol for sterilization, with a low system volume (<3 ml for mouse, <5 ml for rat/guinea pig).
  • Offers options for perfusion pressure measurement and constant pressure perfusion.
  • Components are alcohol-resistant, allowing for sterilization with ethanol.
EasyCell Basic System:
  • Designed for basic research or student labs, suitable for mouse to guinea pig hearts.
  • Features a single perfusion pathway, with a simple transition from clearing buffer to collagenase.
  • Easy to set up, operate, and maintain, with a compact design conserving bench space.
  • Wetted parts can be disinfected with 70% ethanol or autoclaved.
  • Includes a water-jacketed heat exchanger and heart chamber for temperature maintenance.
Key Features and Benefits:
  • Both systems are designed to maximize cell yield and viability by ensuring optimal perfusion conditions.
  • PSCI system allows for multi-organ use, including hepatocyte isolation from rat or mouse liver.
  • EasyCell system is adaptable for other small rodent organs in situ or ex vivo.
Conclusion: The document outlines the specifications, features, and benefits of two cardiomyocyte isolation systems, providing options for both advanced pharmacology labs and basic research settings. Each system is designed to ensure high cell yield and viability while maintaining sterility and ease of use.
See more

Catalog excerpts

Cardiomyocyte Isolation Systems for mouse to small rabbit heart-1

Cardiomyocyte Isolation Systems for mouse to small rabbit heart

 Open the catalog to page 1
Cardiomyocyte Isolation Systems for mouse to small rabbit heart-2

CARDIOMYOCYTE ISOLATION SYSTEMS PSCI PERFUSION SYSTEM FOR CARDIOMYOCYTE ISOLATION The PSCI is designed for pharmacology labs that require reproducible, high-yield viability for their cardiomyocyte assays. The PSCI has two separate perfusion pathways in order to separate clearing buffer from collagenase such that the solutions mix in less than 500 µl, with a simple switch between the two. All solutions recirculate to the aerated reservoir so that they are fresh at all times. The wetted path is compatible with ethanol allowing for a sterile preparation. The system perfusate volume is < 3 ml for...

 Open the catalog to page 2
Cardiomyocyte Isolation Systems for mouse to small rabbit heart-3

PSCI: Perfusion System for Cell Isolation DUAL HEAT  EXCHANGER • Thin-Walled Stainless Steel Heat Exchanger Provides Quick Heating with Minimal Volume • Interchangeable Insert Allows Switchover Between Mouse and Rat Heat Exchangers to Optimize Priming Volumes for the Two Species CARDIOMYOCYTE ISOLATION SYSTEMS CARDIOMYOCYTE ISOLATION SYSTEMS PSCI PERFUSION PERFUSION HUB COLLAGENASE RESERVOIR • olid State Perfusion Circuit Ensures S Thermal Stability, Laminar Flow, and Minimal System Volume • ubble Traps for Each Perfusate B Stream Protect Heart from the Possibility of Air Emboli, Maximizing Cell...

 Open the catalog to page 3
Cardiomyocyte Isolation Systems for mouse to small rabbit heart-4

CARDIOMYOCYTE ISOLATION SYSTEMS PSCI: Perfusion System collected in the collagenase reservoir to which the dissected left ventricle is added for further dissociation, allowing an increased total cell yield. The apparatus is so designed that the individual steps required for preparing the cells can proceed as simply and clearly as possible. With two separate perfusion circuits, the organ can be switched between clearing buffer for removal of blood cells and collagenase buffer for organ digestion by means of a custom, precision-milled changeover stopcock. Using the standard configuration, perfusion...

 Open the catalog to page 4
Cardiomyocyte Isolation Systems for mouse to small rabbit heart-5

psci perfusion PSCI: Core Systems and Options PSCI-MH 73-4424 (115V) or 73-4425 (230V) •••• Core system PSCI for mouse cardiomyocyte isolation Includes: • PSCI-MH Base System for mouse heart • Thermocirculator • Analog Roller Pump and Tubing (Tygon) • Aortic Cannula for mouse heart, 1.0 mm • Protease Reservoir • Mini Magnetic Stirrer • Holder for Pressure Transducer • 0.5 L Jacketed Buffer Reservoir and Tube Set PSCI-RH 73-4426 (115V) or 73-4427 (230V) •••• Core system PSCI for rat or guinea pig cardiomyocyte isolation Includes: • PSCI-RH Base System for rat/guinea pig heart • Thermocirculator...

 Open the catalog to page 5
Cardiomyocyte Isolation Systems for mouse to small rabbit heart-6

CARDIOMYOCYTE ISOLATION SYSTEMS EasyCell: Simple System for Cell Extraction PULSATION DAMPENING • ir Vessel/Compliance Chamber A Dampens Perfusion Pressure Pulsation Generated by the Peristaltic Pump • erves as a Primary Bubble Trap S to Prevent Air Emboli from Causing Regional Ischemia, Increasing Potential Cell Yield TEMPERATURE CONTROL • ater-Jacketed Heat Exchanger W and Heart Chamber for Maintenance of Physiological Temperature FEATURES & BENEFITS • esigned for Cardiomyocyte D Isolation from Small Rodent Hearts • an be Adapted for Other Small C Rodent Organs In Situ or Ex Vivo • imple Constant...

 Open the catalog to page 6
Cardiomyocyte Isolation Systems for mouse to small rabbit heart-7

EasyCell System for Cardiomyocyte Isolation a warmed, aerated standard perfusion buffer for blanching/clearing the heart of blood and then with a warmed, aerated protease solution for tissue disintegration. Unlike the PSCI system, the clearing buffer and collagenase share the same perfusion line, slightly delaying the delivery of the collagenase after switching over from the clearing buffer. The wetted components of the perfusion circuit can be flushed with a 70% ethanol solution or autoclaved for sterilization purposes should the cells need to be incubated for a number of hours following isolation...

 Open the catalog to page 7
Cardiomyocyte Isolation Systems for mouse to small rabbit heart-8

HUGO SACHS ELEKTRONIK HARVARD The Physiology Specialists APPARATUS 84 October Hill Road Holliston, MA 01746 phone: 508.893.8999 toll-free: 800.272.2775 fax: 508.429.5732 email: [email protected] web: www.harvardapparatus.com, www.hugo-sachs.de Cardiomyocyte Isolation Systems for mouse to small rabbit heart www.hugo-sachs.de • www.harvardapparatus.com © Copyright Hugo Sachs Eiektronik - Harvard Apparatus

 Open the catalog to page 8

All Panlab catalogs and technical brochures

  1. Barnes maze

    1  Page

  2. IR Actimeter

    4  Pages

  3. Pumps

    124  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.