MucoHard™

MucoHard™

MucoHard™

Product catalog summary
Product Identification
Product Name: MucoHard+ Bonding Liner
Use: Self-Cured, Hard Reline/Repair Resin
Supplier: Parkell, Inc., Edgewood, NY
Emergency Contact: INFOTRAC 1-352-323-3500 (International), 1-800-535-5053 (North America)
Hazards Identification
State: Liquid
Classification: Acute toxicity (Oral), Skin corrosion/irritation, Eye damage/irritation, Skin sensitization, Carcinogenicity, Specific target organ toxicity
Signal Word: Warning
Hazard Statements: Harmful if swallowed, causes skin and eye irritation, may cause allergic skin reaction, suspected of causing cancer, may cause respiratory irritation and organ damage through prolonged exposure.
Precautionary Measures
Prevention: Use personal protective equipment, avoid inhalation, ensure proper ventilation.
Response: Seek medical advice if exposed. Rinse eyes and skin if contact occurs.
Storage: Store locked up in a well-ventilated area.
Disposal: Dispose of contents/container in accordance with local regulations.
Composition
Key Ingredients: Methylene chloride, Benzoyl peroxide
Note: Specific chemical identities and percentages are proprietary.
First Aid Measures
General: Seek medical attention if exposed.
Eye Contact: Rinse with water and seek medical attention if irritation persists.
Skin Contact: Wash with soap and water, remove contaminated clothing.
Inhalation: Move to fresh air and rest.
Ingestion: Rinse mouth and seek medical advice if unwell.
Fire-Fighting Measures
Extinguishing Media: Water spray, dry chemical, CO2, foam.
Protective Equipment: Self-contained breathing apparatus and full protective gear.
Accidental Release Measures
Personal Precautions: Use protective equipment.
Environmental Precautions: Prevent entry into waterways.
Clean-Up: Contain and collect with inert absorbent.
Handling and Storage
Handling: Use protective equipment, avoid inhalation, ensure ventilation.
Storage: Store in a locked, well-ventilated area, away from incompatible materials.
Exposure Controls/Personal Protection
Exposure Limits: Methylene chloride and Benzoyl peroxide have specific exposure limits.
Protection: Use safety goggles, gloves, and respiratory protection as needed.
Physical and Chemical Properties
State: Liquid
Boiling Point: 39.75°C
Vapor Pressure: 349 mm Hg
Auto-ignition Temperature: 556°C
Stability and Reactivity
Stability: Stable under recommended conditions.
Incompatible Materials: Acids, alkalis, oxidizing agents.
Decomposition Products: Carbon oxides, phosgene, hydrochloric acid.
Toxicological Information
Routes of Exposure: Eye, skin, inhalation, ingestion.
Carcinogenicity: Suspected of causing cancer.
Symptoms: Skin and eye irritation, respiratory issues, potential organ damage.
Ecological Information
Ecotoxicity: Not classified as environmentally hazardous, but large spills may be harmful.
Bioaccumulation: Not determined.
Disposal Considerations
Waste Disposal: Follow local regulations for disposal.
Packaging Disposal: Dispose of in accordance with local regulations.
Transport Information
Not regulated under DOT, IATA, IMDG.
Regulatory Information
Listed on various international chemical inventories.
Regulatory Inventories: PICCS, AICS
US Federal Regulations: CERCLA, SARA 311/312, SARA 313
Clean Water Act: Methylene chloride is listed as a toxic and priority pollutant and hazardous substance.
US State Regulations: California Proposition 65, State Right-to-Know
Other Information
NFPA Ratings: Health Hazards: 2, Flammability: 3, Instability: 3
Disclaimer: The information is provided as guidance for safe handling and is not a warranty or quality specification.
See more

Catalog excerpts

MucoHard™-1

Safety Data Sheet Revision Date: 7-June-2022 Version 1 1. IDENTIFICATION Product Identifier Product Name MucoHard+ Bonding Liner Recommended use of the chemical and restrictions on use Recommended Use Self-Cured, Hard Reline/Repair Resin. Details of the supplier of the safety data sheet Supplier Address Parkell, Inc. 300 Executive Drive Edgewood, NY 11717 Emergency Telephone Number Company Phone Number (631)249-1134 Emergency Telephone (24 hr) INfOtRAC 1-352-323-3500 (International) Signal Word Warning Hazard statements Harmful if swallowed Causes skin irritation Causes serious eye irritation May cause an allergic skin reaction Suspected of causing cancer May cause respiratory irritation. May cause drowsiness or dizziness May cause damage to organs through prolonged or repeated exposure

 Open the catalog to page 1
MucoHard™-2

S642- MucoHard™+ Bonding Liner Precautionary Statements - Prevention Obtain special instructions before use Do not handle until all safety precautions have been read and understood Use personal protective equipment as required Wash face, hands and any exposed skin thoroughly after handling Do not eat, drink or smoke when using this product Contaminated work clothing must not be allowed out of the workplace Do not breathe dust/fume/gas/mist/vapors/spray Use only outdoors or in a well-ventilated area Wear protective gloves/protective clothing/eye protection/face protection Precautionary Statements...

 Open the catalog to page 2
MucoHard™-3

S642- MucoHard™+ Bonding Liner Call a poison center or doctor/physician if you feel unwell. Rinse mouth. Most important symptoms and effects Symptoms Harmful if swallowed. Causes skin irritation. Causes serious eye irritation. May cause an allergic skin reaction. Suspected of causing cancer. May cause respiratory irritation. May cause drowsiness or dizziness. May cause damage to organs through prolonged or repeated exposure. Indication of any immediate medical attention and special treatment needed Notes to Physician Treat symptomatically. 5. FIRE-FIGHTING MEASURES Suitable Extinguishing Media...

 Open the catalog to page 3
MucoHard™-4

S642- MucoHard™+ Bonding Liner Conditions for safe storage, including any incompatibilities Storage Conditions Store locked up. Store in a well-ventilated place. Keep container tightly closed. Incompatible Materials Acids. Alkalis. Oxidizing agents. Chemically active metals. Exposure Guidelines Appropriate engineering controls Engineering Controls Ensure adequate ventilation, especially in confined areas. Eyewash stations. Showers. Skin and Body Protection Impervious protective gloves. Respiratory Protection Use self-contained breathing apparatus when needed. General Hygiene Considerations Handle...

 Open the catalog to page 4
MucoHard™-5

S642- MucoHard™+ Bonding Liner Property Decomposition Temperature Kinematic Viscosity Dynamic Viscosity Explosive Properties Oxidizing Properties Values Not determined Not determined Not determined Not determined Not determined Remarks • Method 10. STABILITY AND REACTIVITY Reactivity Not reactive under normal conditions. Chemical Stability Stable under recommended storage conditions. Possibility of Hazardous Reactions None under normal processing. Hazardous Polymerization Hazardous polymerization does not occur. Conditions to Avoid Avoid heat, ignition sources, moisture, aging, and contamination....

 Open the catalog to page 5
MucoHard™-6

S642- MucoHard™+ Bonding Liner Carcinogenicity The table below indicates whether each agency has listed any ingredient as a carcinogen. However, the product as a whole has not been tested. Suspected of causing cancer. Other Adverse Effects Not determined

 Open the catalog to page 6
MucoHard™-7

S642- MucoHard™+ Bonding Liner 13. DISPOSAL CONSIDERATIONS Waste T reatment Methods Contaminated Packaging Disposal should be in accordance with applicable regional, national and local laws and regulations. Disposal should be in accordance with applicable regional, national and local laws and regulations. Please see current shipping paper for most up to date shipping information, including exemptions and special circumstances. Not regulated Not regulated Not regulated

 Open the catalog to page 7
MucoHard™-8

S642- MucoHard™+ Bonding Liner 15. REGULATORY INFORMATION International Inventories

 Open the catalog to page 8
MucoHard™-9

S642- MucoHard™+ Bonding Liner 16. OTHER INFORMATION NFPA HMIS Issue Date: Revision Date: Revision Note: Health Hazards 2 Health Hazards Not determined Flammability 3 Flammability Not determined Instability 3 Physical hazards Not determined Special Hazards Not determined Personal Protection Not determined Disclaimer The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release...

 Open the catalog to page 9

All Parkell Inc. catalogs and technical brochures

  1. SNAP®

    8  Pages

  2. Digitest® 3

    72  Pages

  3. Predicta™

    25  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.