Analytical Gas Systems Products for TOC Analysis - 1

Analytical Gas Systems Products for TOC Analysis Bulletin AGS-TOC-B aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding

Open the catalog to page 1
Analytical Gas Systems Products for TOC Analysis - 2

Parker Hannifin Corporation The Global Leader in Motion and Control Technologies We engineer success of our customers around the world, drawing upon nine core motion and control technologies. These technolgies enable virtually every machine and process to operate accurately, efficiently and dependably. As the global leader in motion and control, we partner with our distributors to increase our customers’ productivity and profitability by delivering an unmatchable breadth of engineered components and value-added services. We continue to grow with our customers by creating application-focused...

Open the catalog to page 2
Analytical Gas Systems Products for TOC Analysis - 3

Table of Contents Page Voltage Appendix Recommended Gas Generators Additional Parker Products

Open the catalog to page 3
Analytical Gas Systems Products for TOC Analysis - 4

TOC Gas Generator The Parker Balston® TOC Gas Generators produce carrier/ combustion gas, from an existing compressed air supply for TOC instruments, eliminating the need to purchase expensive, inconvenient, high pressure cylinders of air, nitrogen, or oxygen. The generators utilize catalytic oxidation and pressure swing adsorption technologies to remove hydrocarbons to 0.05 ppm (measured as methane), CO2 to 1 ppm, water vapor to 1 ppm, and CO to 1 ppm. Parker Balston TOC Gas Generators eliminate all the inconveniences and costs of cylinder gas supplies and dependence on outside vendors....

Open the catalog to page 4
Analytical Gas Systems Products for TOC Analysis - 5

Max. TOC Gas Flow Rate (outlet) at 100 psig Outlet Hydrocarbon Concentration (as methane) Inlet and Outlet Port Connections Min/Max Inlet Air Pressure Min Required Inlet Air Flow at 100 psig Max Inlet Hydrocarbon Concentration (as methane) methane) Pressure Drop at Maximum Flow Rate Shipping Weight NOTES: 1 Refer to voltage appendix for electrical and plug configurations for outside North America. Ordering Information for assistance, call 800-343-4048, 8 to 5 Eastern Time Model Number Preventive Maintenance Plan Principal Specifications

Open the catalog to page 5
Analytical Gas Systems Products for TOC Analysis - 6

Nitrogen Generator for TOC The Parker Balston Models HPN2-1100 and UHPN2-1100 Nitrogen Generators can produce up to 1.1 lpm of ultra high purity nitrogen gas. These systems are completely engineered to transform standard compressed air into ultra high purity nitrogen, exceeding the specification of UHP cylinder gas. Nitrogen is produced by utilizing a combination of state-of-the art purification technologies and high efficiency filtration. Pressure swing adsorption removes O2, CO2, and water vapor. A catalyst module is incorporated in the UHPN2-1100 to oxidize hydrocarbons from the inlet...

Open the catalog to page 6
Analytical Gas Systems Products for TOC Analysis - 7

Nitrogen Generator for TOC Model Max Nitrogen flow rate Nitrogen Purity Hydrocarbon concentration Min/Max Inlet Pressure 60 psig/125 psig (6 bar) 130 psig/145 psig N/A              (9 to 9.9 bar) (9 to 9.9 bar) N/A Outlet Pressure Integral Compressor Recommended Inlet Temperature ­ 78°F (25°C) Ambient Operating Temperature Inlet Connection Outlet Connection Power Consumption Shipping Weight NOTES 1 Purity specification for Nitrogen does not include Argon concentration. 2 Refer to voltage appendix for electrical and plug configurations for outside North America Ordering Information for...

Open the catalog to page 7
Analytical Gas Systems Products for TOC Analysis - 8

Gas Receiving Tanks The Parker Balston Gas Receiving tanks are highly recommended for supplying gas to pressure sensitive instrumentation, for the storage of compressed nitrogen from nitrogen generators, and for other instruments requiring an occasional high flow burst of compressed gas in excess of the normal capacity of a Parker Balston Gas Generator. Parker Balston Model 72-007 Receiving Tank The Model 72-007 has a maximum pressure rating of 240 psig. At 240 psig, the 72-007 will hold approximately 1.7 scf (50 liters) of compressed gas. Features and Benefits • Aluminum construction...

Open the catalog to page 8
Analytical Gas Systems Products for TOC Analysis - 9

Voltage Appendix 220vac / 50hz configuration for locations where final plug configuration is unknown Order Part Number * Units will be supplied only with IEC connector as depicted, power cord to be customer supplied 220vac / 50hz plug configuration for Australia Order Part Number Order Part Number Voltage Appendix

Open the catalog to page 9
Analytical Gas Systems Products for TOC Analysis - 10

Recommended Gas Generators for Analytical Instruments Instrument Flow Rates Generator Recommendation/Model Atomic Absorption Air for Oxidant Gas Clean, Dry 1-7 SCFM (AA) with Flame Atomic Thermal Zero Air Clean, Dry, Hydrocarbon-free Up to 1600 ml/min. Desorber Hydrogen for FID Fuel Clean, Dry,High Purity Up to 40 ml/min. per FID Zero Air or TOC Gas Generator (HPZA-3500 or TOC-1250) Hydrogen Generator (H2PEM-100, H2PEM-165) (H2PEM-260, H2PEM-510) Atmospheric Pressure Air for Nebulizer Gas Clean, Dry, Hydrocarbon-free < 30 LPM Ionization (API-MS) Nitrogen for Curtain, Sheath, and Shield gas...

Open the catalog to page 10
Analytical Gas Systems Products for TOC Analysis - 11

Flow Rates Generator Recommendation/Model GC-TCD Hydrogen as Carrier & Reference Gas Ultra High Purity Varies Hydrogen Generator (H2PD-300) LC/MS Nitrogen as a Curtain Gas LC/MS Grade 3-30 lpm ICP Spectrometer Nitrogen as Optic/Camera Purge Ultra High Purity <1-5 lpm Nuclear Magnetic Air for Lifting, Spinning Clean, Dry <10 SCFM Air Dryer Resonance (NMR) (UDA-300NA) Gas Generator Lab (74-5041NA) Ozone Generator Supply Air Clean, Dry .3-20 SCFM Protein Analyzer Dry Air, Nitrogen Clean, Dry 40 psig Nitrogen Generator (N2-14, N2-22, NitroFlowLab, N2-35) Solvent Evaporators Nitrogen Clean, Dry...

Open the catalog to page 11
Analytical Gas Systems Products for TOC Analysis - 12

Additional Parker Balston Products Products for LC/MS & Evaporation (Request Bulletin AGS-LCMS) • High purity nitrogen for LCMS instruments and solvent evaporation • Tri-gas units available for instruments that require nitrogen, dry air and zero grade air • Produce a continuous supply of high purity nitrogen from an existing compressed air supply • Integrated compressor systems eliminate the need for house air • Systems available to support one or dozens Products for Chromatography (Request Bulletin AGS-Chromatography) • Hydrogen, Zero Air and UHP Nitrogen Generators for Gas Chromatography...

Open the catalog to page 12