APSS-2000
2Pages

{{requestButtons}}

Catalog excerpts

APSS-2000 - 1

Automated Parenteral Sampling System Sizes and counts suspended particulate matter in a wide range of liquids to meet regulation standards BENEFITS The APSS-2000 syringe sampling system sizes and counts suspended particulate matter in a wide range of liquids and meets or exceeds all current USP, EP, and JP requirements. Recipe functions allow the APSS-2000 to adapt to future regulatory changes. The APSS-2000 system consists of an SLS-2000 syringe sampler, a LiQuilaz® II E Series light obscuration spectrometer, and SamplerSight Pharma software, allowing reports to meet 21 CFR Part 11 regulations. Defect Reduction • 100% sample volume for greater accuracy • A precise sample volume within 0.4 ml is achieved with the syringe sampler, producing repeatable results • SamplerSight Pharma software comes with a Validation Information Notebook, providing comprehensive software development documentation and full IQ, OQ, and PQ protocols • SamplerSight Pharma complies with FDA 21 CFR 11 User-Friendly • Reduce operator error and ensure process accuracy with recipes for repeat sample processing to USP, EP, or JP standards • Automated particle counter calibration wizard for full calibration or routine verification • Alarm levels for pass/fail criteria ensure quality control • Automated backup scheduling ensures enhanced data integrity Comprehensive System • Easy-to-use pull-down menus • Active Directory security password maintains system integrity • Particle measurements are reported per ml or per container values • Small sample volume minimizes waste of expensive product • Various custom report formats are available • Electronic report approval Particle size capability from 1.5 to 125 µm Fifteen user-selectable sizing channels Meets and exceeds all USP, EP and JP requirements Sample volumes from 0.4 ml to 1 liter Adapters for SVI and IV bag testing Automated sensor calibration Plug and play ultrasonic bath and magnetic stirrer options available A P P L I C AT I O N S • Pharmaceutical parenteral monitoring to USP, EP, JP and FDA • • • • standards Parts/medical device cleanliness testing Laboratory water sampling Water for Injection (WFI) and Pu

Open the catalog to page 1
APSS-2000 - 2

Automated Parenteral Sampling System Liquid Sensor Size Range Size Channels Flow Rates Volume Sampled Maximum Concentration Sample Temperature Zero-count Level Capillary Size Maximum Pressure Maximum Sample Viscosity Laser Source Laser diode Wetted Surface Materials 1 Fused Silica, Black Quartz, Teflon, Kel-F®, Kalrez® Greater than 90% accuracy (less than 10% coincidence loss) at maximum recommended concentration. Liquid Sampler Syringe Size Sampling Mode Minimum Sample Volume Wetted Surface Materials Glass, Teflon 17.1 x 9 x 15 in (43.4 x 22.9 x 38.1 cm) Including particle counter Weight...

Open the catalog to page 2

All Particle Measuring Systems catalogs and technical brochures

  1. Lasair Pro

    2 Pages

  2. Airnet® IIs

    2 Pages