Overview: The document describes the features and specifications of Peak Scientific's Calibration Gas Generators, specifically the CG15L and CG22L models. These generators are designed to produce high-purity calibration gas for emissions monitoring and analysis, meeting the Federal Register Specification 40CFR 86.114-79.
Specifications:
  • Models: CG15L and CG22L
  • Calibration Gas Flow Rate: 15 L/min for CG15L and 22 L/min for CG22L
  • Pressure Dewpoint: -70°C / -94°F
  • Required Inlet Air Pressure: 4-8 bar
  • Required Inlet Flow: 27 L/min for CG15L and 44 L/min for CG22L
  • Warm-Up Time: 30 minutes for specified THC
  • Gas Outlets: 1x 1/4” BSP Female
  • Electrical Requirements: 220v 4.5A / 120v 5.0A for CG15L and 220v 8.8A / 120v 9.5A for CG22L
  • Power Consumption: 1100 watts at 220v / 540 watts at 120v for CG15L and 2090 watts at 220v / 1056 watts at 120v for CG22L
  • Dimensions: CG15L - 62 x 43 x 41 cm / 24 x 17 x 16 ins; CG22L - 88 x 43 x 41 cm / 35 x 17 x 16 ins
  • Weight: 58 kg / 128 lbs for CG15L and 73 kg / 161 lbs for CG22L
Features & Benefits:
  • Qualified: Meets Federal Register Specification 40CFR 86.114-79
  • Purity: Provides continuous high-purity calibration gas
  • Durable: Minimal maintenance with few moving parts
  • Quiet: Operates silently
  • Mobile: Can be positioned flexibly as needed
  • Simple Installation: Requires only connection to air source and application
  • Economical: More cost-effective than other gas supply methods
  • Convenient: Provides gas on demand without health hazards or supply concerns
Maintenance and Ordering Information:
  • Annual Service Kit: CG Range 08-4703
  • Standard Maintenance Plan: 09-3110
  • Complete Maintenance Plan: 09-3010
Contact Information: For more details, visit www.peakscientific.com or contact Peak Scientific via email at [email protected].
Accreditations: Peak Scientific’s Quality Management System conforms to ISO:9001:2008.
See more

Catalog excerpts

CG Range Leaflet-1

Calibration Gas Generators CG15L - 22L The gas produced by this range of generators exceeds performance levels of Zero Air and is ideal for a wide variety of air emission applications. Gas is generated by both catalytic oxidation and a proprietary regenerative sieve. Coalescing pre-filters and a final filter ensure continuous gas purity. The CG models are the choice for properly zeroing emissions gas analysers during calibration and meet the requirements of Federal Register Specification 40CFR 86.114-79. PEAK SCIENTIFIC. GO WITH THE FLOW.

 Open the catalog to page 1
CG Range Leaflet-2

Calibration Gas Generators CG15L - 22L Features & Benefits: Qualified – Meets requirements of Federal Register Specification 40CFR 86.114-79 The CG Generators offer the purest source of calibration gas for your CO2 Analyzer, ensuring the cleanest possible starting point for emissions measurement, monitoring and analysis. Purity – Continuous high purity calibration gas for emissions monitoring Durable – Few moving parts with minimum maintenance requirements Quiet – Completely silent in operation Mobile – Flexibility to position generator where required Simple Installation – Generator only needs...

 Open the catalog to page 2