video corpo

Intura

Intura

Intura

Product catalog summary
Overview: The Intura gas generators by PEAK Scientific are designed specifically for Gas Chromatography (GC) and GC-MS applications, offering a reliable and sustainable gas supply solution. These generators provide hydrogen, nitrogen, and zero air, ensuring high sensitivity and accuracy for laboratory needs.
Key Features:
  • Safe and consistent supply of GC carrier and detector gases.
  • Models available for hydrogen, nitrogen, and zero air to meet diverse GC requirements.
  • Adjustable pressure and multiple flow options.
  • Low cost of ownership and sustainable gas supply with low power consumption.
  • Comprehensive 12-month warranty with an option to extend up to 5 years in select regions.
Technical Specifications:
  • Intura Hydrogen: Flow rate up to 1500 cc/min, purity of 99.99999%, output pressure of 175 psi.
  • Intura Nitrogen: Flow rate up to 1000 cc/min, purity of 99.9995%, output pressure of 100 psi.
  • Intura Nitrogen & Zero Air: Flow rate up to 1000 cc/min for nitrogen and 3500 cc/min for zero air, purity of 99.9995% for nitrogen.
  • Intura Zero Air: Flow rate up to 15000 cc/min, purity with CH4 <0.05ppm.
Safety and Performance: Intura generators feature low internal gas volume, multiple fail-safe features, and international safety compliance. They include constant pressure monitoring and an ASME-rated pressure relief valve to prevent hazards. The generators have been tested for purity by the National Physical Laboratory.
Environmental Impact: Intura generators reduce operational carbon emissions due to low power consumption and heat output. The compact design minimizes transportation emissions.
Carrier Gas Transition: Switching from helium to hydrogen carrier gas is encouraged due to rising helium costs and availability issues. Hydrogen offers faster carrier run times and cost efficiency.
Support and Maintenance: PEAK Scientific provides on-site maintenance support through certified field service engineers across over 25 countries, ensuring rapid response and high productivity for laboratories.
See more

Catalog excerpts

Intura-1

Designed for GC. Made for you. peakscientific.com/intura Hydrogen, Nitrogen and Zero Air gas generators for GC

 Open the catalog to page 1
Intura-2

Designed for GC. Made for you. The dedicated gas solution for GC and GC-MS, Intura, has been meticulously developed by PEAK Scientific, the world leader in laboratory instrument gas. Delivering best value, the most reliable solutions and supporting the highest sensitivity & accuracy, Intura is for GC users everywhere. With Intura, look forward to: ) Safe, convenient and consistent GC carrier and detector gas H2, N2 & Zero Air models to meet your GC needs Adjustable pressure and multiple flow options Low ongoing cost of ownership Gas generators tested and validated to highest international standards...

 Open the catalog to page 2
Intura-3

Intura: Where quality meets innovation As the world’s number one for laboratory gas generation with over 25 years of experience and solutions approved and validated by the leading instrument manufacturers, PEAK Scientific’s team of gas generation experts have delivered yet another set of engineering advances with Intura. Using proprietary technologies developed by PEAK’s world-class R&D team, Intura incorporates new approaches to gas purification along with tried and tested components from our LC-MS range to enhance the performance and reliability of the Intura range. Providing the best quality...

 Open the catalog to page 3
Intura-4

Intura Hydrogen With flow rates ranging from 100 to 1500 cc/min, Intura Hydrogen is the cornerstone of the Intura range. This benchtop solution uses electrolysis to separate oxygen and hydrogen from deionized water using tried and tested PEM cell technology, providing a reliable and sustainable source of carrier and detector gas for GC and GC-MS. Intura Nitrogen & Zero Air With flow rate models ranging from 250 to 1000 cc/min Nitrogen and up to 3500 cc/min Zero Air, Intura N2|ZA produces ultra-high-purity N2 with an additional supply of clean, dry, hydrocarbon-free air. The optimized pressure...

 Open the catalog to page 4
Intura-5

Safety first Intura’s low internal gas volume, multiple fail-safe features and full suite of international safety and compliance marks ensure that you can rest assured that Intura is the safest method of hydrogen supply in the laboratory. Constant internal pressure monitoring and an ASME-rated pressure relief valve ensures that Intura will detect any leak and immediately stop production of gas to prevent any hazard. In addition, Intura has undergone EN-60079-2 compliant safety testing to confirm that there is no risk of fire or explosion in the event of a full system failure, ensuring the safety...

 Open the catalog to page 5
Intura-6

Carrier gas run times up to 40% faster with Hydrogen when compared with Helium. Carrier run time: Why switch carrier gas? As helium costs increase and availability becomes more uncertain. A switch to hydrogen carrier gas allows you to take control of your gas supply, reduce costs and improve efficiency. It’s all about the method Switching carrier gas used to be a daunting thought for GC users, however, with the leading instrument vendors offering simple conversion tools and apparatus to support the change, it’s never been a better time to upgrade your gas supply from helium cylinders to an on demand...

 Open the catalog to page 6
Intura-7

Where we protect All Peak on-site maintenance support is delivered by a Peak certified field service engineer, no matter where you are located. Having a dedicated network of fully certified engineers spanning across over 25 countries in every continent allows us to provide an industry-leading rapid response service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top priority. Local PEAK Office [PEAK Protected] direct Protected by approved agents Third party coverage

 Open the catalog to page 7
Intura-8

^Phthalate & BHT free | **C0 / NOx / SOx / Phthalate free | ***NOx / SOx / Phthalate free | **** CO / NOx / SOx / Phthalate free, <0.05ppmCH4, dOppm C02 Contact us today to discover more! North America Tel: +1 866 647 1649ChinaTel: +86 21 5079 1190 Web: peakscientific.com/intura Copyright 2025 Peak Scientific - Intura Brochure Rev 3 RSID 5431 EN - 08/09/2025

 Open the catalog to page 8

All Peak Scientific Instruments catalogs and technical brochures

  1. TOC 1000

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.