1. Catalogs
  2. PerkinElmer
  3. The FilterMate Universal Harvester

The FilterMate Universal Harvester

The FilterMate Universal Harvester

The FilterMate Universal Harvester

Product catalog summary
Overview: The FilterMate Harvester by PerkinElmer is a versatile tool designed for efficient sample processing and transfer in various scintillation and luminescence counters. It supports multiple configurations for different counter models, including MicroBeta®, TopCount®, Tri-Carb®, and WIZARD®.
Key Features:
  • Flexible usage with 96- or 24-well formats, suitable for both deep- and shallow-well plates.
  • Short fluid path to minimize wash fluid usage and ensure thorough washing.
  • Separate waste lines for radioactive waste management.
  • Versatile base-unit for quick switching between 96- and 24-well formats.
  • Built-in scrubbers for easy detachment of adherent cells.
Applications:
  • Cell proliferation assays
  • Cytotoxicity assays
  • Receptor binding assays
  • Nucleic acid degradation
  • Trichloroacetic acid preparations
  • Cell wash station for adherent cell assays
Model Configurations:
  • UniFilter Harvester: Ideal for TopCount users, configured for harvesting UniFilter plates with built-in filters for optimized membrane receptor or cell harvesting.
  • Filtermat Harvester: Best for MicroBeta users, designed for harvesting onto MicroBeta filtermats with easy conversion between applications.
  • OmniFilter Harvester: Suitable for custom filtermats on TopCount, Tri-Carb, and WIZARD counters, allowing for easy disk cutting and transfer.
Design and Performance:
  • Consistent harvesting and washing across different plate types.
  • Direct sample transfer reduces time and minimizes sample issues.
  • Concentric design ensures reproducible results and prevents sample crossover.
  • Three push buttons for vacuum and wash control, reducing waste disposal costs.
Ordering Information: Various models and accessories are available, including specific harvesters for different applications, converter kits, and maintenance kits. For more details, visit PerkinElmer's website or contact their sales office.
See more

Catalog excerpts

The FilterMate Universal Harvester-1

The FilterMate Universal Harvester Simple simultaneous harvesting of samples from 96- and 24-well microplates Harvesting cells is fast and easy with PerkinElmer’s FilterMate™ Universal Harvester. Our compact system harvests and washes all 96 or 24 samples simultaneously from shallow- or deepwell microplates. The FilterMate Harvester is available in several versatile configurations. There are FilterMate models suited for either our MicroBeta® or TopCount® Scintillation and Luminescence Counters, as well as a model designed for cutting filtermats for our Tri-Carb® Liquid Scintillation Counters or WIZARD® Automatic Gamma Counters. With any FilterMate model, it takes only minutes to process and transfer samples — onto integrated filter plates such as UniFilter® plates for counting on TopCount; onto dedicated filtermats for counting on MicroBeta; or onto plain filtermats with the OmniFilter™ harvester configuration. With the OmniFilter FilterMate, you can leave filtermats intact and count them on a TopCount, or cut them into individual filter disks and transfer them easily into individual gamma or liquid scintillation counting vials for counting on a WIZARD or Tri-Carb. The UniFilter and MicroBeta FilterMate Harvesters are available in stainless steel to provide increased resistance to TCA (trichloroacetic acid). UniFilter FilterMate Harvester • Separate hot and cold waste lines — helps minimize radioactive waste. • Versatile base-unit — enables switching from 96to 24-well format and back in just a few minutes. • Built-in scrubbers — make it easy to detach adherent cells from well bottoms and ensure complete harvesting. Key Applications • Cell proliferation assays (tritiated thymidine uptake) • Cytotoxicity assays • Receptor binding assays • Nucleic acid degradation Key Features • Trichloroacetic acid preparations • Flexible — use 96- or 24-well formats, deepor shallow-well plates. • Cell wash station for adherent cell assays • Short fluid path — minimizes the amount of wash fluid required and ensures more complete washing. w w w. p e r k i n e l m e r. c o m

 Open the catalog to page 1
The FilterMate Universal Harvester-2

Choose the FilterMate Model Suited for Your PerkinElmer Counter Order a FilterMate Harvester set-up for the filter plates or filtermats best suited for your PerkinElmer microplate, LSC or gamma counter. Any FilterMate is easily adapted to handle the alternative microplate size — 96- or 24-wells. UniFilter Harvester—Ideal for TopCount Users This FilterMate Harvester is configured for harvesting UniFilter plates for analysis on the TopCount Microplate Scintillation and Luminescence Counters. UniFilters are 96- or 24-well microplates with built-in GF/B® or GF/C® filters for optimized harvesting...

 Open the catalog to page 2
The FilterMate Universal Harvester-3

FilterMate For MicroBeta Filter Head Design Prevents Sample Crossover Harvesting 96 or 24 samples in a small area creates the potential for samples to migrate on the filter during harvesting. During counting, this can cause erroneous results because of the unpredictable migration of activity between sample areas. Regardless of the configuration or the method of analysis, the FilterMate is designed to give accurate results for the most demanding assays. • When harvesting onto filter sheets or MicroBeta filtermats, the force of the FilterMate O-rings against the stainless steel support plate prevents...

 Open the catalog to page 3
The FilterMate Universal Harvester-4

FilterMate Harvester and Accessories Ordering Information Cat. No. Description Cat. No. Description D961241 Filtermat-24 Harvester for MicroBeta 6005226 OmniFilter Template, Cutting Template to Fit Filters into OmniFilter Plate D961962 Filtermat-96 Harvester for MicroBeta C961960 OmniFilter-96 Harvester for TopCount OmniFilter Applications or Cutting Filters for Tri-Carb or WIZARD Counting 7601410 OmniFilter Upper Head 7601370 Replacement Waste Bottle Kit (Does Not Include Tubing) C961241 UniFilter-24 Harvester for TopCount 7601412 UniFilter-24 Upper Head C961961 UniFilter-96 Harvester for TopCount...

 Open the catalog to page 4