Group: PerkinElmer
Catalog excerpts
Verify. Quantify. Simplify. For the Better
Open the catalog to page 1BUILT TO OUTRUN. ENGINEERED TO OUTPERFORM. With today’s ever more complex and demanding laboratory workflows, quality of data is everything. It’s often no longer enough to determine simply what’s in a sample; you need to measure precisely how much and in what form. And quickly. ™ Enter the Flexar SQ 300 MS. Ideal for a variety of analyses, this cutting-edge single quadrupole detector brings the unsurpassed sample insight of mass spectrometry to liquid chromatography applications. An integral part of PerkinElmer’s acclaimed Flexar™ LC product line, the SQ 300 MS features a revolutionary...
Open the catalog to page 2STARTS WITH Create the ideal system with the front-end flexibility and power of the Flexar LC platform. The Flexar SQ 300 MS detector has been designed for seamless integration with the Flexar family of LC solutions. With a globa reputation for robust performance and superior chromatographic separation capabilities, the Flexar platform offers an unparalleled level of configuration and application flexibility. The Flexar line offers the perfect high-performance front-end LC solution to complement the sensitivity, speed and sample insight of the Flexar SQ 300 MS. With the widest array of...
Open the catalog to page 3Patented technologies provide high quality spectra and more informative data. The instrument’s innovative ion source design enables effective nebulization, faster desolvation and superior ionization for unmatched sensitivity in LC/MS applications. With a choice of three ion source options, the Flexar SQ 300 MS allows you to utilize the one that will best address your analytical needs: • Ultraspray™ Electrospray Interface (ESI) • ual-probe Ultraspray2™ ESI D • tmospheric Pressure Chemical Ionization (APCI) A No matter which source you choose, it comes with a unique interchangeable snap-in...
Open the catalog to page 4Ultraspray Electrospray Ionization (ESI) Source. Ultraspray2 Electrospray Ionization (ESI) Source. The Ultraspray ESI on the Flexar SQ 300 MS offers extremely efficient, super-soft ionization to preserve the molecular structure of even the weakest compounds. The dual-probe Ultraspray2 ESI option allows simultaneous connection of multiple analytical channels to your interface. With this design, one inlet may be used solely for calibrant, eliminating the time required to flush lines, and avoiding contamination of the sample probe. The unique angled design of the probe speeds the desolvation...
Open the catalog to page 5Unique design delivers exceptional sensitivity and speed. The Flexar SQ 300 MS features a patented capillary technology that efficiently drives molecules into the mass spectrometer. The voltage applied to the capillary exit can be precisely modulated to allow ions to flow freely or to collide and fragment through Collision-Induced Dissociation (CID). Ideal for obtaining more detailed mass-specific and structural information, CID can be performed more reproducibly and reliably than on any other system thanks to the desolvating efficiency of the instrument’s ionization sources. Effective And...
Open the catalog to page 6Instrument control and data acquisition are faster and easier than ever with Chromera. Complete control. Intuitive design. Fast navigation. Clear graphics. Relevant information. It all adds up to the most productive, application-oriented and user-friendly chromatography data system available. Unmatched ease of use. With a clear, intuitive workflow, Chromera ® Chromatography Data System (CDS) simplifies each and every step of your quantitative analysis. All your tools and information are never more than a couple of clicks away so you can quickly and easily control every aspect of your Flexar...
Open the catalog to page 7Optimize performance and validate results with a complete range of quality consumables. PerkinElmer offers a broad array of consumables to enhance the operation of your Flexar SQ 300 MS and accompanying LC system. Tuning the instrument is simple with our proprietary calibration mixes, and specially formulated solutions make it easy to check the performance levels of your ESI in positive/negative ionization. Mass spectrometry-grade vials, caps and septa give you complete sample handling flexibility and our wide range of columns—stretching from analytical to UHPLC in a variety of lengths and...
Open the catalog to page 8All PerkinElmer catalogs and technical brochures
-
Cannabis Testing Solutions
12 Pages
-
STA 8000
4 Pages
-
ScanRI
2 Pages
-
Thermal Analysis
3 Pages
-
Ultra Clean Gas Filters
10 Pages
-
TurboMatrix
8 Pages
-
Clarus® 590/690 GC Systems
8 Pages
-
Titan MPS Microwave
4 Pages
-
PinAAcle 500
8 Pages
-
TurboMatrix
8 Pages
-
Flexar SQ 300 MS Brochure
8 Pages
-
Atomax Brochure
2 Pages
-
NexION 350 ICP-MS Brochure
12 Pages
-
Ultra Clean Gas Filters Catalog
10 Pages
-
AxION iQT GC/MS/MS
4 Pages
-
AxION 2 TOF
8 Pages
-
AxION DSA
8 Pages
-
AxION eDoor SQ
2 Pages
-
Flexar PDA Plus Detector
2 Pages
-
NexION 300 ICP-MS Brochure
12 Pages
-
AAnalyst 200/400 Brochure
12 Pages
-
XRD Detector Series
2 Pages
Archived catalogs
-
FLEXAR™ Liquid Chromatography
12 Pages