NexION® 2000 ICP Mass Spectrometer
12Pages

{{requestButtons}}

Catalog excerpts

NexION® 2000 ICP Mass Spectrometer - 1

ANY INTERFERENCE ANY PARTICLE SIZE NexION® 2000 ICP Mass Spectrometer

Open the catalog to page 1
NexION® 2000 ICP Mass Spectrometer - 2

i me4? M omortol qtr> dilution - * Vcw HdiMesioncf; "JC\/(3JUne»WCtoi’ Inference: ~*)Ofxb arownfite/OCT * ftn« 1 OltlCV ° \Zf_'. lOCvODD-pO^^fe^C data CCf)u6i^of\ Spee.a TRIPLE QUAD POWER MEETS SINGLE QUAD VERSATILITY Unrivaled ppq detection limits. Unparalleled usability. Finally analysts can have the best of both worlds with the groundbreaking NexION® 2000 ICP-MS. The most versatile ICP-MS on the market, the NexION 2000 features an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of...

Open the catalog to page 2
NexION® 2000 ICP Mass Spectrometer - 3

THAT DEFINE The NexION 2000’s technical innovations offer unique benefits to laboratories, both large and small. The most powerful interference removal for the best detection limits Easily and confidently remove interferences with second-generation Universal Cell Technology™, featuring three modes of operation and three gas channels for unsurpassed flexibility and performance. Any Mode With three modes of operation – ­ Standard, Collision, and Reaction – the NexION 2000 combines the simplicity of a collision cell and the efficiency of a controlled reaction cell in one instrument. Any Gas...

Open the catalog to page 3
NexION® 2000 ICP Mass Spectrometer - 4

Low concentration isotopes with no attenuation High concentration isotopes with controlled attenuation Extended Dynamic Range (EDR) controls the number of ions passing through the Universal Cell on an isotope by isotope basis. The most efficient analysis every time Unlike other ICP-MS systems, the NexION 2000, with EDR, lets you adjust signal transmission so you can measure elements with low and high concentrations – in the same sample in the same run. This extends your dynamic range up to 12 orders of magnitude and optimizes productivity while preserving the lifetime of the detector. For...

Open the catalog to page 4
NexION® 2000 ICP Mass Spectrometer - 5

Free-running RF Plasma Generator Provides improved matrix tolerance - Capable of handling the toughest matrices and solvents - Ability to switch between cool and hot plasma in one run - Innovative no cooling, no maintenance LumiCoil technology Universal Cell Technology INNOVATION ■ Quadrupole Ion Deflector Maximizes uptime and productivity - Completely removes unionized material leading to a no-maintenance/ no-replacement cell Allows you to select your ■ Simultaneous Dual Mode Detector Delivers the fastest data acquisition rates on the market - 10x faster than competitive systems (100,000...

Open the catalog to page 5
NexION® 2000 ICP Mass Spectrometer - 6

ROUTINE ANALYSES MADE EASY Even complex analyses are streamlined and simplified with Syngistix™ for ICP-MS software. Designed to mirror your workflow, the intuitive interface features left-toright, icon-based navigation that walks you through an analysis, simplifying every step – from startup to method development to data reporting. Common look, uncommon flexibility A cross-platform software, Syngistix allows users to move from one technology to another around the lab – including AA, ICP, and ICP-MS – using a common, familiar, intuitive interface for enhanced speed, efficiency, and...

Open the catalog to page 6
NexION® 2000 ICP Mass Spectrometer - 7

Logbook feature in Syngistix for ICP-MS Software Reporter feature in Syngistix for ICP-MS Software Analysis/run Flexible quality control checks – Automate the monitoring of everything from calibration to internal standard responses during a run, ensuring reliable data even during unattended operation. Scheduler – Increases workflow efficiency and data reliability by allowing you to automatically schedule instrument optimizations and procedures, including auto-start and shut down, tuning, and multimethod analyses. Reviewer – Displays the sample run list, including method and sample types, in...

Open the catalog to page 7
NexION® 2000 ICP Mass Spectrometer - 8

TESTING MADE SIMPLE Since high levels of some trace elements can be toxic for humans, plants and animals, the detection of trace elements in environmental samples is essential to ensure that living species are not unduly exposed to toxic levels of any of these elements. Whether it is drinking water, effluents, wastewater, sediments or soil, the NexION 2000 ICP-MS is the complete instrument for the analysis of trace elements in environmental samples. Future proofing regardless of the application Speed of analysis meets low maintenance • Offer more services leveraging the system’s...

Open the catalog to page 8
NexION® 2000 ICP Mass Spectrometer - 9

YOUR PRESCRIPTION Testing for elemental impurities in pharmaceutical products is essential to ensure no adverse effects of the drugs on patients. As such, specific regulations such as USP chapters 232/233 and ICH Q3D have been put in place to protect the consumer. To address these demanding regulations, we've created a perfectly integrated, perfectly tailored solution – designed around the NexION 2000 ICP-MS – specifically for USP 232/233 and ICH Q3D compliance. Sample preparation systems USP 232/233 and ICH Q3D toolkit • Simplifies compliance with USP 232/233 and ICH Q3D and makes...

Open the catalog to page 9
NexION® 2000 ICP Mass Spectrometer - 10

GIVING SEMICONDUCTOR TESTING A HELPING HAND Since even ultratrace levels of impurities can cause defects in silicon-based semiconductor devices, detection and control is vital in the industry. The unique combination of patented features and unrivaled detection limits in the tailor-made semiconductor version of the NexION 2000 ICP-MS ensures that your products meet the highest quality standards. Optimized detection limits for every element Space-saving, small footprint • Preserve precious space in your cleanroom with a compact design measuring just 81 x 69 x 75 cm (W x D x H) Sub ppt-level...

Open the catalog to page 10
NexION® 2000 ICP Mass Spectrometer - 11

SINGLE CELLS AND NANOPARTICLES HAVE NOWHERE TO HIDE Single Particle ICP-MS Fast, accurate nanoparticle characterization is becoming increasingly important as nanotechnology becomes more prevalent in consumer, industrial, biotech, and healthcare products. Analysts and researchers will benefit from our expertise and the power of the NexION 2000 ICP-MS. It's uniquely equipped to handle the challenges involved with nanoparticle detection and nanomaterial research, delivering the specificity, resolution, and sensitivity required to ensure fast, reliable results. Single Cell ICP-MS The transfer...

Open the catalog to page 11