XRD Detector Series - 1

P R O D U C T XRD Detector Series N O T E Digital X-ray Flat Panel Detectors Overview The XRD series detectors provide imaging up to 100 frames per second (fps) and up to 16-bit contrast resolution. Applications benefiting from our technology include industrial non-destructive testing (NDT), X-ray systems for oncology treatment (radiation therapy / radiosurgery), veterinary, cone-beam CT (CBCT) imaging and other applications using X-ray based film. Scintillator: 3: Csl (Direct Deposition) Detector Size Interface: 08: 8"x 8" (20 cm x 20 cm) 0: Standard Cu 16: 16" x 16" (41 cm x 41 cm) 1: Fiber Optic 15: DRZ Standard 13: DRZ High 19: PI200 & Cu Filter 14: DRZ Plus 22: DRZ Plus & Cu Filter Other customized options potentially available 2: Gb-Ethernet XRD 1621 AN15 ES Resolution: 2: 200 µm pixel size 4: 400 µm pixel size Electronics: Version: N: 16 bit ADC & 6 Gain Settings ES: Enhanced Speed (if applicable) O: 14 bit ADC & 2 Gain Settings Entrance Window: P: 16 bit ADC & 6 Gain Settings A: Standard 8" & 16" C: Low Energy Application 8" & 16" PerkinElmer Digital X-ray Flat Panel Detectors and accessories are designed as components to be integrated into a complete X-ray system by imaging systems manufacturers. Manufacturers are responsible for qualifying, validating, certifying their intended use in their specific applications and meeting all applicable regulatory requirements established by country and local government authorities. Contents in this document are subject to change without notice. IND: Industrial Version 8" HS: High Sensitivity (for low dose) Other custom indicators possible

Open the catalog to page 1
XRD Detector Series - 2

Detector Series: XRD 1622 xO Detector Series: XRD 0822 xO Pixel Size (µm) 200 (1x1) 400 (2x2) A/D Conversion 14 bit / 78 dB Matrix 1024 x 1024 512 x 512 Pixel Size (µm) 200 (1x1) Frame Rate (fps) 15 30 Matrix 2048 x 2048 A/D Conversion 14 bit / 74 dB Energy Range 20 keV – 15 MeV Frame Rate (fps) 1 Energy Range 20 keV – 15 MeV Model Scintillator Type Application Model Scintillator Type Application XRD 0822 xO3 CsI Low Dose NDT1 XRD 1622 xO3 CsI NDT1,2 Veterinary XRD 0822 xO14 DRZ Plus Veterinary XRD 1622 xO14 DRZ Plus Security XRD 0822 xO15 DRZ Standard Film Replacement XRD 1622 xO15 DRZ...

Open the catalog to page 2

All PerkinElmer catalogs and technical brochures

  1. STA 8000

    4 Pages

  2. ScanRI

    2 Pages

  3. TurboMatrix

    8 Pages

  4. PinAAcle 500

    8 Pages

  5. TurboMatrix

    8 Pages

  6. AxION 2 TOF

    8 Pages

  7. AxION DSA

    8 Pages

Archived catalogs