HiQuad - Mass Spectrometer
14Pages

{{requestButtons}}

Catalog excerpts

HiQuad - Mass Spectrometer - 1

HIQUAD® New high-end mass spectrometer! Fast, flexible and easy to operate.

Open the catalog to page 1
HiQuad - Mass Spectrometer - 2

New high-end mass spectrometer! Fast, flexible and easy to operate. A modular solution for mass spectrometry With the new HiQuad® mass spectrometer, Pfeiffer Vacuum combines high perfor­ ance, flexibility and ease of operation. m As a stand-alone unit, the HiQuad® can be optimally integrated into your application. Depending upon the application in question, it is possible to select: ■■ ■■ ■■ ■■ ■■ Mass ranges Rod diameters Ion sources Detectors Interfaces This mass spectrometer achieves extremely high measurement speeds of up to 125 µs/amu. It is characterized by the highest sensitivity and...

Open the catalog to page 2
HiQuad - Mass Spectrometer - 3

■ Modular, flexible design ■ Simple operation with Quadera® software ■ Extremely high measurement speed ■ Maximum sensitivity and wide dynamic range ■ Outstanding long-term stability ■ Ethernet interface ■ Integral Internet browser and OPC server for communicating with PC-based programs

Open the catalog to page 3
HiQuad - Mass Spectrometer - 4

Wide dynamic range Very fast measurements can be performed with the HiQuad® mass spectrometer. This example shows the mass spec response during respiration analysis. N2, O2 and CO2 were detected with a very fast cycle time. This scan shows a spectrum for air. In addition to the primary components, consisting of N2, O2, Ar and CO2 even minute concentrations of Xe are detected. The ion current at mass 136 is equivalent to a concentration of 7.8 ppb of Xe in air. And it is decades above the background noise level, enabling a wide dynamic range of 10 decades to be achieved.

Open the catalog to page 4
HiQuad - Mass Spectrometer - 5

Overview of technologies Biased ionization chamber Field-axis technology Mass filter Biasing the ionization chamber results in an extremely low background signal. The electron-emitting filament is positively biased by 100 to 150 VDC relative to ground. This design prevents desorption of gas particles from the chamber walls, and thus the generation of an undesired background signal by electron stimulated desorption. One of the most important factors in the performance of a mass spectrometer is the transmission of the ions from the ion source into the mass filter. With the aid of field-axis...

Open the catalog to page 5
HiQuad - Mass Spectrometer - 6

The Quadera® software serves as the interface between the mass spectrometer and the user. It excels as a result of its simple, intuitive operation. Repetitive measurement tasks can be automated by setting recipes and through the macro programming routines. ■ Predefined recipes available, e.g. spectrum, trend, bar graph ■ Easy-to-read mass spectrometer system presentation ■ Automated measurement routines via the integral Visual Basic script editor ■ Adaptation for special applications thanks to interchange with other programs Main window Tools, aids The measured data are shown in the center...

Open the catalog to page 6
HiQuad - Mass Spectrometer - 7

It is possible to display mass spectrometer data together with external data, such as temperature, sample weight, etc. The example in the illlustration shows coupling with a thermobalance. Ei®K bfiOOG MmumwI i#» upw HQj*d r rrrwrtfin I. ,y* fmijcni On fOVTE/TnEM 111 0,r IF' FM F rant vr.rj1 H in l» 02 Fw £ twt L^C41 b JOfiflMOW Oi 1010 PH E -w* Cw» H gw wn^ai MMtMi vwrJ i.-.fr 505123! f rsaapn hmad nri d tilt 500231 iPjecjpe "Scan* Parted Different user-defined views of the same measurement can be displayed simultaneously. 1 Signal vs. time. 2 Bargraph scan of different masses.

Open the catalog to page 7
HiQuad - Mass Spectrometer - 8

Dimensions QMA 400, QMA 430 with 90° off axis SEM QMA 410 with 90° off axis SEM Dimensions in mm * ■ Axial ion source = 26 mm ■ Grid ion source = 27 mm ■ Cross-beam ion source = 35.5 mm (23.5 mm to the center of the sensitive volume) ■ Gas-tight cross-beam ion source = 48 mm (axial gas connection) ■ Three-lens ion optics = 129 mm ■ Cross-beam ion source with axial ion optics = 43.5 mm ■ Cross-beam ion source with three-lens ion optics = 171 mm PFEIFFER^lVACUUM

Open the catalog to page 8
HiQuad - Mass Spectrometer - 9

Detection limit, min. Sensitivity for Ar, min.11 Operating pressure, max. mbar A/mbar Faraday, max. mbar Partial pressure ratio with Analyzer Rod system, material/diameter Radio frequency generator (RF) Electrometer preamplifier Operating temperature/analyzer Bakeout temperature/analyzer21 Connection flange 11 Faraday in deflection unit, standard resolution, cross-beam ion source with magnet, emission 1 mA 21 With magnet, max. 300 °C 31 Stability < 0.1 % in eight hours, contribution to adjacent mass number 40Ar/41

Open the catalog to page 9
HiQuad - Mass Spectrometer - 10

Control unit Software PFEIFFER^ VACUUM

Open the catalog to page 10
HiQuad - Mass Spectrometer - 11

Order number structure 01 – Axial ion source 02 – Cross-beam ion source 03 – Cross-beam ion source with magnet 04 – Gas-tight cross-beam ion source 05 – Gas-tight cross-beam ion source with magnet 06 – Grid ion source – Two-lens ion optics – Three-lens ion optics – Two-lens ion optics with cross-beam ion source – Three-lens ion optics with cross-beam ion source e – Detector and high-voltage power supply

Open the catalog to page 11
HiQuad - Mass Spectrometer - 12

Selection aid - Typical applications and solutions PTQ1 a Applications Analyzer/mass range Ion source/ion optics Analysis of gases or gas mixtures; for trace analysis; less residual gas influence than with open 2, 3, 5 04, 05 ion sources Plasma technology, SIMS, photoionization UHV residual gas analysis, desorption measurements Thermally desorbed ions, electron-induced desorption, SIMS, photoionization, plasma ions 11 For mass range of 1 to 2048 amu, Analyzer QMA 400 with SEM 218 and HV 702 and EP 422 2) With tungsten filament only a - Analyzer/mass range The combination of...

Open the catalog to page 12
HiQuad - Mass Spectrometer - 13

Detector and high-voltage power supply 1 1, 3 f - Preamplifier and ion counter - EP 422: Fast, sensitive preamplifier - CP 400: Ion counting down to 1 count per 10 seconds, wide dynamic range d - Filament - Tungsten: For UHV applications - Yttriated iridium: Low temperatures, high resistance to air inrushes - Rhenium: For residual gas analysis e - Detector and high-voltage power supply - SEM 217 + HV 701: Secondary electron multiplier in combination with a high-voltage power supply for detecting positive ions - SEM 217 + HV 702: For measuring positive and negative ions - SEM 218 + HV...

Open the catalog to page 13

All Pfeiffer Vacuum GmbH catalogs and technical brochures

  1. PRISMAPRO

    10 Pages

  2. ASM 340

    6 Pages

  3. ASI 35

    8 Pages

  4. HIQUAD®

    12 Pages

  5. HiPace 300 H

    8 Pages

  6. HILOBE

    8 Pages

  7. HENALINE

    10 Pages

  8. E-PDQ

    8 Pages

  9. E2, VE2

    8 Pages

  10. LEAK TESTING

    12 Pages

  11. HICUBE™

    18 Pages

  12. ASM 2000

    6 Pages

  13. AMI 1000

    8 Pages

  14. ADH Series

    8 Pages

  15. A4 Series

    10 Pages

  16. A 200 L

    6 Pages

  17. A 100 L ES

    4 Pages

  18. HiPace 30

    4 Pages

  19. Turbopumps

    32 Pages