Softwall Cleanroom Overview
Phamm softwalls provide an efficient and cost-effective solution for creating confined clean areas for critical equipment and processes. They are designed for easy expansion, assembly, and repositioning. The laminar flow area serves to create zones within clean rooms with a higher ISO class than the surrounding area and to provide controlled air quality environments for companies without a clean room.
Construction Details
The cleanroom is constructed from carbon steel painted with epoxy powders or optionally from stainless steel (304 or 306). The ceiling is made from extruded aluminum profiles, and the perimeter is enclosed with anti-static PVC strips. The structure is modular, configurable, and designed to minimize transport costs.
Operating Principle
Air is directed onto work surfaces in a laminar flow, filtered through pre-filters and H14 absolute filters, to prevent particle deposition. The air exits through the gap between the strips and the floor.
Equipment and Options
Standard equipment includes FFU (Filter Fan Unit), LED lamps, and a control unit for lights and FFU. Optional features include alerts for dirty filters, flow control, UV lamp modules, wheels, and configurations for ATEX environments.
Applications
FFU modules are designed for environments requiring clean air and contamination control, suitable for ISO 4/5 classes and compliant with ISO 14644-1 and GMP standards.
FFU Specifications
FFUs generate a laminar air flow of 0.45 m/s ±20% and offer filtration options between HEPA and ULPA filters. They are designed to be housed in self-supporting structures or grids. Specifications include maximum external dimensions, indoor area dimensions, number of compartments, maximum air flow, cleanliness class, number of FFUs and LED lamps, filtering stages, installed power, and power supply requirements.
Components
Key components include HEPA H14 filters, prefilters G4, ECM fans, LED lamps, and anti-static strips. The document also mentions the use of reticular false ceilings and grid structures.
Customization
PHAMM offers tailored Softwalls of any size, with preliminary dimensions provided for popular products. Custom configurations are available upon request, with specific codes for dimensions, mobility, material, lighting, and ISO class.
Additional Information
All data are subject to changes and improvements without notice. Contact information for PHAMM Engineering Srl is provided for further inquiries.
See more

Catalog excerpts

Cleanroom Softwall-1

SOFTWALL Cleanroom AREE PULITE CONFINATE

 Open the catalog to page 1
Cleanroom Softwall-2

- SOFTWALL CLEANROOM - Le softwall Phamm sono la soluzione più avanzata ed economicamente vantaggiosa per la realizzazione di aree pulite confinate di apparecchiature e processi critici. Phamm softwalls are the most advanced and cost-effective solution for the creation of closed clean areas for critical equipment and processes. Le softwall si caratterizzano per la facilità di espansione e per la facilita di montaggio e riposizionamento. Softwalls are characterized by ease of expansion and simple assembly and repositioning. La zona a flusso laminare essenzialmente si utilizza per due scopi. The...

 Open the catalog to page 2
Cleanroom Softwall-3

- SOFTWALL CLEANROOM - La struttura della softwall cleanroom sarà realizzata in acciaio al carbonio verniciato con polveri epossidiche cotte in forno. The Softwall Cleanroom will be built with carbon steel painted with epoxy powders and baked in the oven. The self-supporting filter plenum, designed to house the fan filter units and lighting, will stand on a series of uprights arranged perimetrally, which will be either secured to the ground or fitted with wheels. Il plenum filtrante, dentro il quale troveranno incasso le Unità FFU e l’illuminazione, sarà del tipo autoportante, supportato da una...

 Open the catalog to page 3
Cleanroom Softwall-4

- SOFTWALL CLEANROOM - La structure de la Softwall Cleanroom (Chambre Blanche Softwall) sera en acier au carbone peint avec des poudres époxy cuites au four. La estructura de la Softwall Cleanroom se realiza de acero al carbono pintado con polvos epoxi cocidos en horno. El plénum filtrante, en cuyo interior se encastrarán las unidades FFU y la iluminación, será de tipo autoportante, apoyado en una serie de soportes dispuestos perimetralmente y fijados al suelo o sobre ruedas. Le plénum du filtre, à l’intérieur duquel seront placées les unités FFU et l’éclairage, sera de type autoportant, soutenu...

 Open the catalog to page 4
Cleanroom Softwall-5

- SOFTWALL CLEANROOM - OPERATING PRINCIPLE L’aria verrà convogliata, creando un flusso laminare (filtrata attraverso pre-filtri e filtri assoluti H14) direttamente sulle superfici di lavoro, evitando in particolare che si depositino particelle sui manufatti da assemblare. The air will be conveyed directly onto work surfaces, creating a laminar flow (filtered through pre-filters and absolute filters H14) to prevent particles from depositing on items pending assembly. L’aria verrà espulsa dallo spazio che intercorre tra le bandelle e il pavimento. The air will be expelled through the space between...

 Open the catalog to page 5
Cleanroom Softwall-6

- SOFTWALL CLEANROOM - L’air sera acheminé, créant un écoulement laminaire (filtré à travers des pré-filtres et des filtres absolus H14) directement sur les surfaces de travail, évitant notamment que des particules ne se déposent sur les pièces à assembler. El aire se transporta, creando un flujo laminar (filtrado a través de prefiltros y filtros absolutos H14), directamente sobre las superficies de trabajo, concretamente para evitar que se depositen partículas sobre los artículos a ensamblar. L’air sera expulsé de l’espace entre les bandes et le sol. El aire se expulsa por el espacio que se...

 Open the catalog to page 6
Cleanroom Softwall-7

- SOFTWALL CLEANROOM - I moduli autonomi FFU sono progettati per soddisfare, a costi contenuti, le esigenze di quelle aziende nelle quali è indispensabile operare in ambienti con aria pulita e controllo della contaminazione nelle classi ISO4/5 e secondo ISO 14644-1 e GMP. Le unità sono progettate per essere alloggiate su strutture autoportati o inserite in un reticolo. Generano un flusso d’aria laminare (0,45 m/sec ±20%) con un grado di filtrazione a scelta tra filtro Hepa o Ulpa. Sono idonee per tutte le applicazioni che richiedono controllo della contaminazione. Le unità sono realizzate in più...

 Open the catalog to page 7
Cleanroom Softwall-8

- SOFTWALL CLEANROOM - VENTILATORE ECM FAN ECM VENTILADOR ECM VENTILATEUR ECM FAN ECM PREFILTRO G4 PREFILTER G4 PREFILTRO G4 PRÉFILTRE G4 VORFILTER G4 FILTRO HEPA H14 HEPA H14 FILTER FILTRO HEPA H14 FILTRE HEPA H14 HEPA H14 FILTER CONTROSOFFITTO RETICOLARE RETICULAR FALSE CEILING FALSO TECHO RETICULAR FAUX-PLAFOND RÉTICULAIRE NETZUNTERDECKE FFU SISTEMI DI VENTILAZIONE FFU VENTILATION SYSTEMS FFU UNIDADES VENTILADORAS FFU UNITÉS DE VENTILATION FFU LÜFTUNGSANLAGEN BANDELLE ANTISTATICHE ANTI STATIC STRIPS TIRAS ANTIESTATICAS BANDES ANTISTATIQUES ANTISTATISCHER STREIFENVORHANG STRUTTURA RETICOLARE...

 Open the catalog to page 8
Cleanroom Softwall-9

- SOFTWALL CLEANROOM - ESEMPIO • EXAMPLE • EJEMPLO • EXEMPLE • UMSETZUNGSBEISPIEL CARATTERISTICHE - SPECS - CARACTERÍSTICAS CARACTÉRISTIQUES - TECHNISCHE MERKMALE Dimensioni esterne max (L x P x H) mm Max. external dimensions (W x D x H) mm Dimensiones externas máx. (L x P x A) mm Dimensions extérieures maximales (L x P x H) mm Außendimension max. (L x P x H) mm Dimensioni area interna (L x P x H) mm Dimensions indoor area (W x D x H) mm Dimensiones del área interna (L x P x A) mm Dimensions de la zone interne (L x P x H) mm Abmessungen Innenbereich (L x P x H) mm Numero Vani Number of compartments...

 Open the catalog to page 9
Cleanroom Softwall-10

- SOFTWALL CLEANROOM  CODICE • CODE • CODIGO • CODE • BESTELLCODES PHAMM realizza Softwall di ogni dimensione, studiate su misura. Le misure riportate sono scritte per dare una preliminare identificazione di alcuni prodotti maggiormente richiesti. Altre misure e conformazioni potranno essere realizzate su domanda del cliente. PHAMM builds tailored Softwalls of any size. Measures provided offer a preliminary identification of some of the most popular products. Other measures and configurations may be carried out at the request of the customer. PHAMM produce Softwalls de cualquier tamaño, hechos...

 Open the catalog to page 10
Cleanroom Softwall-11

- SOFTWALL CLEANROOM - Tutti i dati sono suscettibili di variazioni e miglioramenti. PHAMM si riserva il diritto di modificare senza preavviso. All data are subject to changes and improvements. PHAMM reserves the right to change without notice. Todos los datos están sujetos a cambios y mejoras. PHAMM se reserva el derecho a realizar cambios sin previo aviso. Toutes les données sont susceptibles d’être modifiées et améliorées. PHAMM se réserve le droit de modifier sans préavis. Alle Daten unterliegen Änderungen und Verbesserungen. PHAMM behält sich das Recht auf Änderungen ohne vorherige Ankündigu...

 Open the catalog to page 11

All Phamm Engineering catalogs and technical brochures

  1. Hoods

    12  Pages

  2. AIRSHOWER

    9  Pages

  3. PASS THROUGH

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.