Catalog excerpts
Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS100 Staggered or simultaneous stirrer start, manual or automated operation is offered by the advanced ADS-PTWS100 System. It includes an Ismatec Multi Channel Peristaltic Pump and a SA500 UV/VIS Diode Array Spectrophotometer or a Pharma Test T70 UV/VIS split beam UV/VIS Photometer with 8-cell changer or any other suitable spectrophotometer with multiple cell changer. The fully automated closed loop Tablet Dissolution Testing System is controlled by the WinDiss32 Software Suite which is fully 21CFR Part 11 compliant. The PTWS 100 3by2 or 2by3 Lift-Up Dissolution Bath is equipped with insitu Sampling probes. Each sampling tube may be fitted with 5 or 10 micron in-line filters so as to avoid the passage of insoluble excipients into the measurement cells inside the spectrophotometer. The samples to be tested are dropped at the same time into the Dissolution Vessels for simultaneous sampling and measurement. Teflon tubing is connecting the Dissolution Vessels via an 8 channel Peristaltic Pump (IPC 8) to the Photometer with its built-in cuvette changer. All instruments are controlled by the WinDiss32 Software which has to be installed to a suitable PC. As with nearly all sampling systems re-usable in-line filters are attached to the sampling tubes which are placed in the dissolution vessel during the entire test, distance and dimensions are according to the USP directive which states that the sampling point must be exactly half way between the dissolution medium surface and the top of the stirring tool (Paddle, Basket or TD cylinder). At the appropriate pre-programmed time the pump will be switched on and the sample tubing lines to the cuvettes are filled. The pump will be stopped and the spectra measured are transferred from the spectrophotometer to the WinDiss32 +49 6182 9532-600 +49 6182 9532-650 email@pharma-test.de www.pharma-test.com PHARMA TEST AG Siemensstrasse 5 D-63512 Hainburg (GER)
Open the catalog to page 1Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS100 Software for further processing. Also stirring speed, bath and media temperature (optional), sampling and measuring time are logged. As the PTWS 100 is fitted with 6 vessels, then cuvette 8 can be filled with a fresh Reference Standard and cuvette 7 is filled with Blank Media. One or both can be measured each time prior to the measurement sequence. This has an advantage in that minor variations in absorbance values encountered over a series of measurements can be compensated for as each set of measurements is made relative...
Open the catalog to page 2Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS100 On-line Systems Using an automated Dissolution System is offering a good number of advantages, such user free sampling, on-line measurement of drug absorbance, accurate sampling timing, precise sampling positioning using an inside media sampling probe (insitu). Also data correction, using the on-line Standard and/or Blank Media and automated result calculation will save time and offer highest quality data presentation. This popular configuration is elaborate, but allows real time calculation of results using the new fully...
Open the catalog to page 3Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS100 The Photometer We offer different Spectrophotometer Drivers which may be incorporated into the ADSPTWS100 Auto Dissolution Test System. Depending on the application the system should be used for, the user may select between single beam and double beam Photometers or Diode Array Detectors. The use of a single or double beam spectrophotometer is possible if only single or multiple wavelength tests with now timing problem have to be performed. As soon as measuring speed or spectra scanning should be done we recommend the use...
Open the catalog to page 4Fully Automated Tablet Dissolution Testing System - Type ADS DT8 WinDiss32 Software The CFR 21 Part 11 compliant WinDiss32 software drives the system and collects the results. It includes system operation log file, audit trail, user access right administration, password protection and administration, electronic signature, report generator etc. It offers single or multi-component analysis. The ADS System components are controlled and integrated into WinDiss32 Dissolution Data management software which is used by the worlds largest Pharmaceutical companies. Driver Linkage with Unique Solution...
Open the catalog to page 5Fully Automated Tablet Dissolution Testing System - Type ADS DT8 Configurable Centralised Security The Global Settings allow the administrator to set limits to prevent unauthorised access to the data station, Password Expiry, Log Off Times etc for each Access Level. These activities can be performed remotely from any WinDiss32 networked workstation. WinDiss32 provides the user with total management of the signing process, from start to finish. This includes configuring the number of signing levels, the Users for each level, Signer Activity and Meaning. PHARMA TEST AG Siemensstrasse 5...
Open the catalog to page 6Fully Automated Tablet Dissolution Testing System - Signing and Reporting Signed Records Once data is acquired in a Group with signing rights, any report generated will show the signing status for all pages of the record shown on the report. Product Name Method Group Method Group John Broun TEST Liroup Name Station Name Date - Time Quality Control Dtsso lution. Time (hhimmss) Tested by John Brown 05 10 2004 09:50 Analyst Sign Oil Signing Level Supervisor Requires Signing. Signing Level Qualified Person" Requires Signing. PHARMA TEST AG Siemensstrasse 5 D-63512 Hainburg (GER)
Open the catalog to page 7Fully Automated Tablet Dissolution Testing System - Type ADS DT8 Dynamic Report Editor The WinDiss32 report organizer allows users to produce customized reports with the right information by selecting from a combination of objects such as Method Header, Data Tables, Method Parameters, Graphs and the Company Logo. These details may include any parameter measured during the test such as Bath Temperature, Paddle Speed, Time Intervals as well as Absorbance, Concentration and % Dissolved. Any number of pages can be selected with automatic page numbering. Standard Report Format Graphics Printer...
Open the catalog to page 8