ADS 1210
1 / 15Pages

Catalog excerpts

ADS 1210 - 1

Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS1210 Staggered or simultaneous stirrer start, manual or automated operation is offered by the advanced ADS-PTWS1210 System. It includes an Ismatec Multi Channel Peristaltic Pump and a SA500 UV/VIS Diode Array Spectrophotometer or a any other suitable UV/VIS Photometer with minimum 12-cell changer. The fully automated closed loop Tablet Dissolution Testing System is controlled by the WinDiss32 Software Suite which is fully 21CFR Part 11 compliant. The PTWS 1210 6+6+2-station Dissolution Bath is equipped with the EPE Auto-Sampling Manifold and a manual Tablet Drop Magazine. The added advantage of the EPE option is that the sampling probes are only in the dissolution medium when sampling is required. The EPE is raised out of the bath after the sampling sequence is complete. This fulfils the other school of thought that sampling probes should only be in the solution for a minimum period so as to avoid unnecessary solution perturbation. Each sampling tube may be fitted with 5 or 10 micron in-line filters so as to avoid the passage of insoluble excipients into the measurement cells inside the spectrophotometer. Using the Tablet Drop Magazine all 12 samples are dropped at the same time into the Dissolution Vessels for simultaneous sampling and measurement. Teflon tubing is connecting the Dissolution Vessels via an 16 channel Peristaltic Pump (IPC16) to the Photometer with its built-in 16 cuvette changer. All instruments are controlled by the WinDiss32 Software which has to be installed to a suitable PC. As with nearly all sampling systems re-usable in-line filters are attached to the sampling tubes which are only placed in the dissolution vessel while sampling whenever the EPE Sampling System is used. Sampling position, distance and dimensions are according to the USP directive which states that the sampling point must be exactly half way between the dissolution medium surface and the top of the stirring tool (Paddle, Basket or TD cylinder). At the appropriate pre-programmed time the EPE will drive down into sampling position, the +49 6182 9532-600 +49 6182 9532-650 email@pharma-test.de www.pharma-test.com PHARMA TEST AG Siemensstrasse 5 D-63512 Hainburg (GER)

Open the catalog to page 1
ADS 1210 - 2

Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS1210 pump will be switched on and the sample tubing lines to the cuvettes are filled. The pump will be stopped and the spectra measured are transferred from the spectrophotometer to the WinDiss32 Software for further processing. Also stirring speed, bath and media temperature (optional), sampling and measuring time are logged. The ADS 1210 can also be fitted with an optional online temperature monitoring device ITM connected to the EPE system. This will monitor and log the actual media temperature inside the dissolution vessels...

Open the catalog to page 2
ADS 1210 - 3

Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS1210 On-line Systems Using an automated Dissolution System is offering a good number of advantages, such user free sampling, on-line measurement of drug absorbance, accurate sampling timing, precise sampling positioning both either using an inside media sampling probe (insitu) or a removing EPE sampling system which remains only inside the media as long as sampling takes place. Also data correction, using the on-line Standard and/or Blank Media and automated result calculation will save time and offer highest quality data...

Open the catalog to page 3
ADS 1210 - 4

Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS1210 The Photometer We offer different Spectrophotometer Drivers which may be incorporated into the ADSPTWS1210 Auto Dissolution Test System. Depending on the application the system should be used for the user may select between single beam and double beam Photometers or Diode Array Detectors. The use of a single or double spectrophotometer is possible if only single or multiple wavelength tests with now timing problem have to be performed. As soon as measuring speed or spectra scanning should be done we recommend the use of a...

Open the catalog to page 4
ADS 1210 - 5

Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS1210 Driver Linkage with Unique Solution Path Technology • WinDiss32 Supports a wide range of Baths, Auto samplers, Fraction Collectors, Pumps, and other Detectors It uses a Unique Solution Path Technology Configuration for different analysis requires no additional reprogramming. Support for Closed and Open Loop for UV and HPLC systems. WinDiss32 can operate with USP I, II, III and IV methods. Expanded capability for HPLC Collect and store samples in Auto samplers to perform online dilution, mixing and measurement on the ADS....

Open the catalog to page 5
ADS 1210 - 6

Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS1210 Configurable Centralised Security The Global Settings allow the administrator to set limits to prevent unauthorised access to the data station, Password expiry, Log Off Times etc for each access level. These activities can be performed remotely from any WinDiss32 networked workstation. WinDiss32 provides the user with total management of the signing process, from start to finish. This includes configuring the number of signing levels, the Users for each level, Signer Activity and Meaning. PHARMA TEST AG Siemensstrasse 5...

Open the catalog to page 6
ADS 1210 - 7

Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS1210 Signing and Reporting Signed Records Once data is acquired in a Group with signing rights, any report generated will show the signing status for all pages of the record shown on the report. Product Name Method Group Method Group John Brown TEST Group Name Station Name Date - Time Quality Control Dtsso lution. Time (hh:mm:ss) Technician Tested by John Brown 05 10 2004 09:50 Analyst Sign Off Signing Level Supervisor Requires Signing. Signing Level Qualified Person" Requires Signing. PHARMA TEST AG Siemensstrasse 5 D-63512...

Open the catalog to page 7
ADS 1210 - 8

Fully Automated Tablet Dissolution Testing System- Type ADS-PTWS1210 Dynamic Report Editor The WinDiss32 report organizer allows users to produce customized reports with the right information by selecting from a combination of objects such as Method Header, Data Tables, Method Parameters, Graphs and the Company Logo. These details may include any parameter measured during the test such as bath Temperature, Paddle speed, Time Intervals as well as Absorbance, Concentration and % Dissolved. Any number of pages can be selected with automatic page numbering. Standard Report Format Graphics...

Open the catalog to page 8

All Pharma Test Apparatebau catalogs and technical brochures

  1. ADS 70

    14 Pages

  2. ADS 610

    16 Pages

  3. ADS 100

    16 Pages

  4. WinDiss ARGUS

    23 Pages

  5. IDS 1000

    11 Pages

  6. T70

    4 Pages

  7. DFC-620SP

    6 Pages

  8. PTBA 211E

    4 Pages

  9. PTB 302

    6 Pages

  10. PTB 311E

    6 Pages

  11. PTB 111EP

    8 Pages

  12. PTB 111E

    6 Pages

  13. PTWS 820D

    10 Pages

  14. PTWS 120S

    8 Pages

  15. PTWS 120D

    8 Pages

  16. PTWS1210

    3 Pages