The HoloMonitor® M4 is a non-invasive live cell imaging system designed for long-term analysis of cell cultures within standard incubators. It provides real-time data on cell morphology, migration, and proliferation without the need for labels, making it ideal for various research fields including cancer research and drug discovery.

Technology and Features
The system utilizes quantitative phase imaging, allowing for the visualization and quantification of living cells without compromising their integrity. It employs a digital image sensor and low-power diode illumination to measure light direction changes as it passes through unstained cells. This method avoids the phototoxicity associated with traditional microscopy techniques.

Applications
HoloMonitor® M4 is suitable for a wide range of applications, including single-cell tracking, wound healing assays, and dose-response studies. It supports various cell types, including induced pluripotent stem cells and primary human cell cultures. The system's software, App Suite, facilitates data extraction and analysis, offering user-friendly workflows and the ability to export data for further analysis.

Benefits
The system offers several advantages over traditional methods, such as saving time and resources, eliminating the need for expensive consumables, and providing real-time, label-free analysis. It allows for continuous monitoring of cells within the incubator, ensuring minimal disturbance and enabling further use of imaged cells.

Technical Specifications
The HoloMonitor® M4 features a 20x objective, a lateral resolution of 1 μm, and a field of view of 567 μm × 567 μm. It supports various cell culture vessels and operates within a temperature range of 10-40°C. The system requires a Windows 10 computer with specific hardware specifications for optimal performance.

Conclusion
HoloMonitor® M4 represents a significant advancement in live cell imaging, offering a non-invasive, efficient, and versatile solution for cell analysis. Its ability to provide quantitative data without affecting cell viability makes it a valuable tool for researchers in various scientific fields.
See more

Catalog excerpts

HoloMonitor® M4-1

HoloMonitor ® M4 – Non-invasive Live Cell Analysis Non-invasive Live Cell Analysis The HoloMonitor® live cell imaging system enables long-term non-invasive analysis of cell cutures within your standard incubator. Cell biologists worldwide use PHI’s label-free cell imager to automatically obtain live-cell morphology, migration, and proliferation data down to a single-cell level in real-time.

 Open the catalog to page 1
HoloMonitor® M4-2

HoloMonitor ® M4 – Non-invasive Live Cell Analysis To understand and cure the diseases that still plague humanity, medical science needs new tools that gain widespread scientific use by being affordable to all scientists. Close to 20 years ago this, together with the excitement of working with something entirely new, inspired me and a group of engineers to start developing a technology that would allow cell biologists to non-invasively study cells while being cultured inside the incubator. Sweden is the home of PHI, cinnamon buns, ABBA and technology innovations, including the three-point seat...

 Open the catalog to page 2
HoloMonitor® M4-3

Focus on Your Cells Primary human small airway epithelium cells (SAEC) Non-invasive Quantitative Single cell analysis Fits inside the incubator Induced pluripotent stem cells (iPS) Single cell tracking Wound healing of breast cancer cells (JIMT-1) HoloMonitor ® is a live cell imaging system designed to visualize and quantify adherent cells over time. It is gentle to all cell types and can be used to monitor cell lines as well as delicate cell types, such as induced pluripotent stem cells or primary human cell cultures. As cell imaging with HoloMonitor is label–free and harmless to your cells,...

 Open the catalog to page 3
HoloMonitor® M4-4

HoloMonitor ® M4 – Non-invasive Live Cell Analysis User-friendly Applications The HoloMonitor ® software (App Suite) is a powerful tool designed to extract quantitative data about your cells from the holographic images captured by the instrument. The App Suite software is intuitive and guides the user through the simple step–by–step work flow, from experiment setup to result analysis. You can also easily create colorful videos and images for peer-reviewed publications. All data can be exported to Excel for further analysis. Guided End-point Assays Guided Kinetic Assays In-depth Analysis Ensure...

 Open the catalog to page 4
HoloMonitor® M4-5

Standard Way vs. HoloMonitor® Way Standard cell culture methods require various instruments, from plate readers to microscopes. Experiments require multiple setups and consumables and most readouts are indirect as label intensities are measured. HoloMonitor®, on the other hand, enables real-time label free and quantitative studies of your cells directly in the incubator. All information is directly obtained by monitoring cells without any phototoxic damage or other disturbances. Incubation start 2 h 6 h 12 h 24 h 48 h 72 h 96 h Time requirement Standard Way A new experiment is required for other...

 Open the catalog to page 5
HoloMonitor® M4-6

HoloMonitor ® M4 – Non-invasive Live Cell Analysis Defining Your Cells Without Labels HoloMonitor ® is based on quantitative phase imaging enabling non–invasive visualization and quantification of living cells without compromising cell integrity. Unlike phase contrast microscopy, individual cells can be identified using the HoloMonitor technology taking your research to new discovery horizons. Diode laser Reference beam Sample beam Cell culture Parallel laser light Imprinted laser light Image sensor Holographic microscopy creates quantitative phase images by letting a sample beam and a reference...

 Open the catalog to page 6
HoloMonitor® M4-7

Technical Specifications HoloMonitor ® M4 Computer Requirements Light source: External laser unit Operating system: Windows 10, 64–bit Cells: Adherent cell monolayer Processor: Intel Core i7 (8th Gen) Cell culture vessels*: 6-, 24-, 96-well, Petri, IBIDI Other: 2 built–in USB ports * For information about recommended vessels please visit phiab.com/holomonitor/ holomonitor-system/ Autofocusing range: 1.5 mm Image capture rate: 1 image/s Image size: 1024 × 1024 pixels Stage travel range: 100×70×10 (x×y×z) Stage repeatability: 5 μm HoloMonitor® M4 dimensions: 290×200×190 mm (w×d×h) Space required...

 Open the catalog to page 7
HoloMonitor® M4-8

Copyright © 2022, Phase Holographic Imaging PHI AB / Revision 0017 HoloMonitor ® M4 – Non-invasive Live Cell Analysis NORTH AMERICA Phase Holographic Imaging Skiffervägen 48 224 78, Lund Sweden [email protected] Phase Holographic Imaging PHI Inc. 256 Franklin St., Suite 1702 Boston, MA 02110 USA [email protected] Phase Holographic Imaging PHI AB Skiffervägen 48, 224 78 Lund, Sweden / +46 46 38 60 80 / [email protected] /