Cryogenic Vials Brochure
2Pages

{{requestButtons}}

Catalog excerpts

Cryogenic Vials Brochure - 1

CRYOGENIC VIALS CRYOGENIC VIALS for cryopreservation and transport can be used to safely store valuable samples such as cells, serum, and antibodies. The cryogenic vials have a silicone packing which is attached to the cap of the vials to ensure high airtightness and prevent drying of samples and liquid leakage. FEATURES OF CRYOGENIC VIALS  Excellent airtightness, leak tested in accordance with IATA (International Air Transport Association) international standards, for air transportation packaging.  Can be stored for a prolonged period of time at -190 ºC.  Easy loading and unloading of samples prevent contamination of the outer wall of the tube due to dripping.  Various special racks for easy handling are also available. 2 types of caps: outer cap and inner cap 4 capacities inner cap: 1.2 ml, 2 ml, 4 ml, 5 ml 4 capacities outer cap: 1 ml, 2 ml, 4 ml, 5 ml 5 cap colours: white, red, yellow, blue, green (a 5-colour mix set is also available) Various special boxes are also available  MS-7550L, MS-7550G, MS-7550P, MS-75600 Lock Stand: MS-78000  Locked at its bottom, the tube’s cap can be opened and closed with one hand. SLIM TUBES Our original “Slim Tube” is a centrifuge compatible product. Using regular tubes you need to transfer samples to a different tube which is centrifuge compatible, this increases the risk of contamination whilst transfering the samples. Since the slim tube is a centrifuge compatible tube, the risk of contamination due to transfering tubes is avoided. Centrifugal operation is possible due to the narrow body diameter. Max Cent

Open the catalog to page 1
Cryogenic Vials Brochure - 2

CRYOGENIC VIALS PRODUCT TYPE PRODUCT SPECIFICATIONS  Material: polypropylene.  Sterilization: radiation sterilized.  Pyrogen & endotoxin Free: endotoxin level less than 0.5 EU/mL (in accordance with the Japanese Pharmacopoeia endotoxin test method).  Sealing pressure: 95kPa pressure tested (In accordance with IATA PI602/650). Leak test conducted by a third-party organization.  Liquid nitrogen: storage in gas phase possible.  Autoclave: yes (121°C, 20 min).  Cytotoxicity: no toxicity (Intraocular lens approval standard. Cell growth inhibition test. Agar diffusion test). ...

Open the catalog to page 2

All PHC Europe B.V. / PHCbi catalogs and technical brochures

  1. VIP Brochure

    16 Pages

  2. MPR-1014R-PE

    2 Pages

Archived catalogs

  1. MLS

    2 Pages

  2. MDF-U5412-PE

    2 Pages

  3. MDF-U731M-PE

    2 Pages

  4. MIR-162/262

    2 Pages