PATHFAST™ EMERGENCY & CRITICAL CARE - 1

EMERGENCY & CRITICAL CARE » 6 samples in parallel » in less than 17 minutes » from whole blood » in central lab quality in, CK-MB mass NTproBNP, D-Dimer, hsCRP, Myoglob hs Trop I, tes in parallel Quantitative measurement of 6 anal

Open the catalog to page 1
PATHFAST™ EMERGENCY & CRITICAL CARE - 2

Central lab quality at the point of care The PATHFAST TM analysis system combines the accuracy of a full-scale lab with the flexibility of a mobile solution. Best prerequisites for fast differential diagnosis at the point of care. Easy to operate, install and network. Highest pre ision c make this device an adequate „outpost” of a full-scale lab on a cardiology, intensive care or emergency ward. Parallel processing enables the examination of six samples in <17 minutes. Parallel Processing for fast action Six parallel channels. Six quantitative analysis simultaneously. Six results in < 17...

Open the catalog to page 2
PATHFAST™ EMERGENCY & CRITICAL CARE - 3

hs Trop I, NTproBNP, D-Dimer, hsCRP, Myoglobin, CK-MB mass Diagnostic safety through parallel scanning of all significant markers High sensitivity Troponin I High sensitivity cTnI results are used to assist in the diagnosis of acute myocardial infarction and to aid in the risk stratification of patients with acute coronary syndromes with respect to their relative risk of mortality.1-6 Assay range Precision at low concentrations The imprecision profile at low concentrations was determined by using plasma samples. The within-run and total standard deviations were calculated by CLSI EP5-A2...

Open the catalog to page 3
PATHFAST™ EMERGENCY & CRITICAL CARE - 4

Quantitative results within <17 minutes Secured results of all biomarkers in critical care Risk stratification with NYHA classification Blood samples were obtained from 72 patients diagnosed with congested heart failure (CHF). The descriptive studies and New York Heart Association (NYHA) functional classes are provided. All CHF Elevated CRP levels are always associated with pathological changes and CRP provides information for the diagnosis, therapy, and monitoring of inflammatory conditions and associated diseases. D-Dimer The D-Dimer concentration is an indicator for the fibrinolytic...

Open the catalog to page 4
PATHFAST™ EMERGENCY & CRITICAL CARE - 5

The highly precise, fast and compact chemiluminescence immunoassay analysis system PATHFAST TM Test Principle PATHFAST TM Technical Specifications Instrument type Throughput Measuring time Sampling material Measuring principle Desktop Immunoassay Analyzer Up to 6 samples or parameters per run <17 min for 6 samples using emergency markers Whole blood, plasma, serum Analysis takes place with the help of the chemiluminescence enzyme immunoassay technology (CLEIA) and Magtration® technology. 37 °C 100 µl Patient data: 1000, QC data: 1800, CAL data: 300 ASTM standard 28 kg 100 - 240 V AC (50/60...

Open the catalog to page 5
PATHFAST™ EMERGENCY & CRITICAL CARE - 6

Product List PATHFAST TM for critical care and sepsis diagnostics Item number Pack size PATHFAST TM pipette tips PATHFAST TM B.R. A.H.M.S PCT control set PATHFAST TM Presepsin control set SYSTEM PATHFAST TM Immunoanalyser Analyzer for the detection of cardiac and other emergency parameters and sepsis CONSUMABLES AND ACCESSORIES REAGENT KITS FOR CRITICAL CARE DIAGNOSTICS PHC Europe B.V. Nijverheidsweg 120, 4879 AZ Etten-Leur, The Netherlands Phone: + 31 76 543 38 33 email: marketing@eu.phchd.com REAGENT KITS FOR SEPSIS DIAGNOSTICS

Open the catalog to page 6

All PHC Europe B.V. / PHCbi catalogs and technical brochures

  1. VIP Brochure

    16 Pages

  2. MPR-1014R-PE

    2 Pages

Archived catalogs

  1. MLS

    2 Pages

  2. MDF-U5412-PE

    2 Pages

  3. MDF-U731M-PE

    2 Pages

  4. MIR-162/262

    2 Pages