Overview
The document details the TwinGuard Ultra Low Temperature Freezers, designed for secure storage of high-value samples. These freezers feature a Dual Cooling System, ensuring protection by using two independent refrigeration systems to maintain a uniform temperature in the -70°C range, even if one system fails.
Specifications
The freezers are available in models MDF-DU502VX-PE, MDF-DU702VX-PE, MDF-DC500VX-PE, and MDF-DC700VX-PE, with capacities from 528 to 729 liters, storing 384 to 576 2” boxes. Certified as Class IIa Medical Devices, they are suitable for storing sensitive samples like human cells, organs, plasma, and DNA.
Key Features
  • Dual Cooling System: Provides redundancy and maintains temperature in case of system failure.
  • Ease of Use: Managed by a microprocessor controller with an LCD touch panel for easy monitoring and control.
  • Filterless Design: Reduces maintenance time by eliminating the need for regular filter cleaning.
  • VIP PLUS Insulation: Offers up to 30% more storage capacity without increasing the footprint.
  • Temperature Uniformity: Ensures stable temperatures and quick recovery times to protect sample integrity.
Applications
Ideal for storing temperature-sensitive samples such as therapeutics, biospecimens, stem cells, engineered tissues, vaccines, and other valuable pharmaceutical products. Suitable for clinical trials and high-security laboratory samples.
Innovative Design
Features a patented VIP vacuum insulation panel design, providing more interior storage volume within a conventional footprint. Includes multiple access ports, an EZlatch door handle, and a manual vacuum release port for ease of use.
Energy Efficiency
Operates in Normal or ECO mode, with ECO mode reducing energy consumption while maintaining optimal temperature uniformity. Compressors are designed for ultra-low temperature applications, enhancing energy efficiency and extending compressor life.
Monitoring and Control
Integrated microprocessor controller with a touchscreen display simplifies freezer functions, including alarm, programming, and diagnostic protocols. A USB port allows easy data transfer to a PC.
Conclusion
TwinGuard Ultra Low Temperature Freezers offer advanced features and robust design for the secure storage of high-value samples, ensuring reliability and efficiency in various scientific and medical applications.
Additional Specifications
  • Dimensions: External dimensions range from 790 x 882 x 1993 mm to 2300 x 845 x 1070 mm.
  • Performance: Cooling performance is consistent at -86°C, with a temperature setting range of -50 to -90°C.
  • Refrigeration: Utilizes an independent dual-cooling system with HFC mixed refrigerant and PUF/VIP Plus insulation.
  • Construction: Exterior is painted steel, with interior options of painted or stainless steel. Includes outer door locks and vacuum release ports.
  • Alarms: Visual, buzzer, and remote alarms for power failure, high and low temperature, and door open.
  • Electrical and Noise Level: Operates at 230V, 50Hz with a noise level of 52 dB[A].
Options and Accessories
  • Liquid CO2 and N2 back-up systems available.
  • Temperature recorders include circular and continuous strip types with associated chart paper and ink pens.
  • Small inner door kits and various rack configurations are available for different storage needs.
Performance Data
Graphs illustrate pull-up and pull-down temperature characteristics during power failure, indicating robust temperature maintenance capabilities.
Contact Information
Panasonic Biomedical Sales Europe B.V., located in Etten-Leur, Netherlands, provides contact details for further inquiries.
See more

Catalog excerpts

TwinGuard ULT Freezers brochure-1

In April 2018, our Biomedical Business Brand will change to PHCbi ULTRA LOW TEMPERATURE FREEZERS The most secure ultra-low temperature freezers for the storage of high value samples. Alongside exceptional ease-of-use and data monitoring, the Dual Cooling System provides the highest level of protection through the use of two independent refrigeration systems.

 Open the catalog to page 1
TwinGuard ULT Freezers brochure-2

ULTRA LOW TEMPERATURE FREEZERS TwinGuard Upright Freezers TwinGuard Chest Freezers The most secure ultra-low temperature freezers for the storage of high value samples TwinGuard Ultra Low Temperature Freezers with Dual Cooling Technology offer the highest level of security for high-value samples. Alongside exceptional ease-of-use and data monitoring, the Dual Cooling System provides the highest level of protection through the use of two independent refrigeration systems. If one system unexpectedly fails, the other can maintain the freezer’s temperature uniformly in the -70°C range. Developed...

 Open the catalog to page 2
TwinGuard ULT Freezers brochure-3

In the case of unexpected failure of one of the cooling circuits, the other circuit will maintain the freezer continuously in the -70°C range. Medical Device Directive Panasonic has become one of the first companies in our industry to introduce Medical Device certification to underline our strong commitment to product design, quality and safety. In 2010, Panasonic was awarded certification by TUV-Sud to manufacture blood bank refrigerators, freezers and incubators as Class Ila Medical Devices according to the directives 93/42/EEC and 2007/47/EC. At the same time our quality systems were updated...

 Open the catalog to page 3
TwinGuard ULT Freezers brochure-4

TwinGuard ULT Freezers ULTIMATE SAMPLE PROTECTION The Dual Cooling System offers the highest level of protection through the use of two independent refrigeration systems. If one system unexpectedly fails the other can maintain the freezer in the -70°C range. ENHANCED USE & INTELLIGENT SECURITY The freezers are managed and monitored by an integrated microprocessor controller with a comprehensive alarm system and diagnostic functions. Status and control of parameters are accessible via an LCD information centre. The EZlatch, on the upright models, makes access to stored samples even easier. A colour...

 Open the catalog to page 4
TwinGuard ULT Freezers brochure-5

SAMPLE PROTECTION & OPTIMUM CAPACITY Models: MDF-DU502VX-PE | MDF-DU702VX-PE | MDF-DC500VX-PE | MDF-DC700VX-PE DUAL COOLING SYSTEM Within TwinGuard’s independent Dual Cooling System, efficient ultra-low cooling is achieved through two independent evaporator circuits surrounding the interior chamber. Two independent evaporator circuits -86ºC VIP PLUS vacuum insulation provides up to 30% more storage capacity than a conventionally insulated freezer, without increasing the footprint. A glass fibre core provides advanced thermal properties. Innovative design Panasonic was the first company to introduce...

 Open the catalog to page 5
TwinGuard ULT Freezers brochure-6

SAMPLE PROTECTION Models: MDF-DU502VX-PE | MDF-DU702VX-PE | MDF-DC500VX-PE | MDF-DC700VX-PE • Each refrigeration circuit includes a closed-loop cold-wall evaporator configured in parallel to the other. Two independent refrigeration systems • If a component, such as a compressor, fails in a conventional ULT freezer with single or cascade refrigeration circuits with mutually dependent high and low stage systems, the whole system will fail and the freezer will eventually rise to room temperature, putting samples at serious risk of degradation. • Independent compressors, evaporators and cooling fans...

 Open the catalog to page 6
TwinGuard ULT Freezers brochure-7

INDUSTRY FIRST INTELLIGENT ECO MODE OPERATION The TwinGuard ULT Freezers can be set to Normal or ECO mode operation, depending on the requirements of the user. Although both refrigeration systems are completely independent, ECO mode establishes an overlapping cycle to significantly reduce energy consumption while maintaining optimum interior uniformity for protection of high value materials. Normal mode maintains the most repeatable, cycling wave form for the strictest of GMP applications. Pull-down Stable temperature CHAMBER TEMP COMPRESSOR A COMPRESSOR B COMP A/B COMPLEMENTARY OPERATION...

 Open the catalog to page 7
TwinGuard ULT Freezers brochure-8

CABINET CONSTRUCTION Models: MDF-DU502VX-PE | MDF-DU702VX-PE An automatic vacuum release port allows smooth door opening when a vacuum has been formed due to the large different in ambient and chamber temperature during previous door opening. A manual vacuum release port allows smooth door opening in case of unexpected failure of the automatic vacuum release port. The EZlatch door handle makes access to stored samples even easier. Multiple access ports permit insertion of independent probes, instrumentation or liquid CO2 back-up injectors. Gasketed inner doors seal inside to offer additional...

 Open the catalog to page 8
TwinGuard ULT Freezers brochure-9

MICROPROCESSOR CONTROL WITH TOUCH SCREEN DISPLAY The TwinGuard ULT Freezers are managed by an integrated microprocessor controller with LCD touchscreen to simplify all freezer functions. Uniform ultra-low temperature is achieved through a combination of performance systems supervised by the controller complete with alarm, programming and diagnostic protocols. The built in USB port allows logged data to be easily transferred to a PC. Touch Panel Legend 1. Present temperature display field: The current chamber temperature is displayed. 2. Set temperature value display field: The set value of chamber...

 Open the catalog to page 9
TwinGuard ULT Freezers brochure-10

^Exterior dimensions of main cabinet only, excluding handle and other external projections - See dimensions drawings on website for full details 21 Air temperature measured at freezer centre, ambient temperature +30°C, no load 31 Max. load is the total of the load distributed over all shelves (3) and chamber bottom surface. The weight is the maximum load for chamber inside and excludes load on casters equipped with product. 4 Nominal value. Background noise 20dB 51 Usable storage capacity will be 320 x 2" boxes with installation of MDF-5ID5-PW and additional shelf 61 Usable storage capacity will...

 Open the catalog to page 10
TwinGuard ULT Freezers brochure-11

TwinGuard Chest Freezers

 Open the catalog to page 11
TwinGuard ULT Freezers brochure-12

Pull-up characteristics during power failure Pull-down characteristics Pull-up characteristics during power failure Pull-down chnrncterirticn Pull-up cCaractc>risticc during ppwer failure Pull-down cCaraateristicc Pull-up characteristics during power failure Pull-down characteristics Panasonic* Panasonic Biomedical Sales Europe B.V. Nijverheidsweg 120 | 4879 AZ | Etten-Leur | Netherlands T: +31 (0) 76 543 3839 | F: +31 (0) 76 541 3732 www.panasonic-healthcare.com/eu/biomedical © Panasonic Printed in NL V080817TM

 Open the catalog to page 12

All PHC Europe catalogs and technical brochures

  1. ULT Brochure

    52  Pages

  2. VIP Brochure

    16  Pages

  3. MPR-1014R-PE

    2  Pages

  4. MPR-N450FH-PE

    2  Pages

Archived catalogs

  1. MLS

    2  Pages

  2. MIR-162/262

    2  Pages

  3. MIR-H163-H263

    2  Pages

  4. MDF-U731M-PE

    2  Pages

  5. MDF-U5412-PE

    2  Pages

  6. MDF-U3386S-PE

    2  Pages

  7. MDF-U4186S-PE

    2  Pages

  8. MDF-U5386S-PE

    2  Pages

  9. MDF-U700VX-PE

    2  Pages

  10. MDF-U500VX-PE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.