Overview
The p48 MW Flow Modulation Device is designed to enhance safety in distal anatomies by bringing flow diversion to a new level. It is manufactured by phenox GmbH and is not approved for sale in the United States.

Specifications
The device is available in various sizes, with maximum vessel diameters ranging from 2 mm to 3 mm and implant lengths varying accordingly. It is compatible with a 0.021″ microcatheter.

Key Features
  • Visibility: The device uses platinum-filled DFT wires for full visibility, combining radiopacity with the superelastic deformability of nitinol.
  • Safety: It features an independently movable inner distal wire made of flexible nitinol with an atraumatic tip, enhancing safety in tortuous and fragile vessels.
  • Radiopacity: The fully visible braided mesh allows for optimal wall apposition and precise positioning. A radiopaque marker indicates the "point of no return" for resheathing.

Illustrative Case
An example of a right PICA aneurysm treated with the p48 MW demonstrates its application in neurovascular interventions, highlighting its technological advances in aneurysm treatment.

Conclusion
The p48 MW Flow Modulation Device represents a significant advancement in the treatment of neurovascular aneurysms, particularly in sensitive distal anatomies, by providing enhanced visibility, safety, and precision.
See more

Catalog excerpts

p48 MW-1

Flow Modulation Device p48 MW Compatible with 0.021″ MC Max. vessel diameter [mm] Implant length in max. vessel [mm]* Implant length in min. vessel [mm]* See the p48 MW in action scan the QR-code or visit http://bit.ly/p48Flow Enhanced safety in distal anatomies. Bringing flow diversion to a new level. *Length is defined as: length of implant measured in straight silicone vessel without aneurysm neck. phenox GmbH | Lise-Meitner-Allee 31 | D-44801 Bochum | Germany www.phenox.net | Tel. +49 234 36 919 0 | Fax +49 234 36 919 19

 Open the catalog to page 1
p48 MW-2

Flow Modulation Device The p48 MW Flow Modulation Device comprises the latest technological advances in the field of neurovascular aneurysm treatment. 48 drawn filled tubing (DFT) wires form a fully visible braided mesh to combine the radiopacity of platinum with the superelastic deformability of nitinol. Illustrative Case of right PICA aneurysm treated with p48 MW Extending the concept of flow diversion to distal anatomies means operating in an even more sensitive environment. Thus, the p48 MW is compatible with 0.021″ microcatheters and provides a movable inner distal wire enabling enhanced...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.