1. Catalogs
  2. Phenox
  3. pRE set Thrombectomy Device

pRE set Thrombectomy Device

pRE set Thrombectomy Device

pRE set Thrombectomy Device

Product catalog summary
Overview
The pREset Thrombectomy Device is designed for the treatment of acute ischemic stroke, offering a range of devices suitable for different thrombus loads and occlusion locations. The device is particularly focused on time-critical situations where rapid intervention is necessary.

Device Specifications
- pREset 4-20 and 6-30: Suitable for large thrombus loads in carotid "T" and proximal MCA occlusions.
- pREset LITE 4-20 and 3-20: Designed for distal MCA occlusions.
- Unique proximal "ring" design ensures stable opening and reduced tapering when withdrawn.
- Helical slit maintains cell shape integrity and optimizes radial force distribution.

Performance and Design
The device offers absolute radial force over usable lengths of Ø 2mm and Ø 3mm, ensuring effective recanalization of occluded vessels. The design minimizes tapering, which is crucial for maintaining vessel integrity during withdrawal.

Case Study
A 50-year-old male with carotid "T" and M2 occlusion was successfully treated using the pREset 6-30 and pREset LITE 4-20 devices. The case demonstrated full recanalization of the carotid "T" and M2 occlusions.

Technical Specifications
  • pREset 4-20: Shaft Diameter: 4mm, Shaft Length: 30mm, Insertion Wire Length: 1800mm, Marker Distance: 1260mm, Working Length: 20mm, Min. ID Microcatheter: 0.021 inch, Min. vessel diameter: >2mm.
  • pREset 6-30: Shaft Diameter: 6mm, Shaft Length: 48mm, Insertion Wire Length: 1800mm, Marker Distance: 1275mm, Working Length: 30mm, Min. ID Microcatheter: 0.021 inch, Min. vessel diameter: >3mm.
  • pREset LITE 3-20: Shaft Diameter: 3mm, Shaft Length: 30mm, Insertion Wire Length: 1800mm, Marker Distance: 1255mm, Working Length: 20mm, Min. ID Microcatheter: 0.0165 inch, Min. vessel diameter: >1.5mm.
  • pREset LITE 4-20: Shaft Diameter: 4mm, Shaft Length: 30mm, Insertion Wire Length: 1800mm, Marker Distance: 1255mm, Working Length: 20mm, Min. ID Microcatheter: 0.0165 inch, Min. vessel diameter: >1.5mm.

Contact Information
phenox GmbH, Lise-Meitner-Allee 31, D-44801 Bochum, Germany. Tel: +49 (0) 234 - 36 919 - 0, Fax: +49 (0) 234 - 36 919 - 19, Website: www.phenox.net, Email: [email protected]

Conclusion
The pREset Thrombectomy Device offers a comprehensive range of options for the treatment of acute ischemic stroke, with specific designs to address various occlusion challenges effectively.
See more

Catalog excerpts

pRE set Thrombectomy Device-1

pREset Thrombectomy Device Cathlab Inspired When Time is Critical... Choose from the broadest range of devices for the treatment of acute ischemic stroke

 Open the catalog to page 1
pRE set Thrombectomy Device-2

pREset Thrombectomy Device The Clock is ticking... pREset and pREset LITE - the right choice for acute thrombotic occlusions • pREset 4-20 and 6-30 for large thrombus load in carotid “T” and proximal MCA occlusions • NEW pREset LITE 4-20 and 3-20 for treatment of distal MCA occlusions • Unique proximal “ring” design ensures stable opening and reduced tapering when withdrawn • The helical slit maintains cell shape integrity and enables optimized radial force distribution Absolute radial force over usable length in Ø 2mm Absolute radial force over usable l

 Open the catalog to page 2
pRE set Thrombectomy Device-3

pREset Thrombectomy Device When Time is Critical... Less Tapering can make the Difference. Unique proximal “ring” design ensures stable opening and reduced tapering when withdrawn The helical slit maintains cell shape integrity and enables optimized radial force distribution Other Stent Retriever 50 y/o male with carotid “T” and M2 occlusion treated with pREset 6-30 and pREset LITE 4-20 Carotid “T” occlusion caused by a cervical ICA occlusion. (Cervical ICA already recanalized by stent angioplasty, images not shown.) Catheterization of M2 inferior branch. Recanalization with pREset 6-30. Carotid...

 Open the catalog to page 3
pRE set Thrombectomy Device-4

Thrombectomy Device Cathlab Inspired The broadest range of devices for the treatment of acute ischemic stroke Cathlab Inspired phenox GmbH I Lise-Meitner-Allee 31 I D-44801 Bochum, Germany

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.