BrightView X and XCT
6Pages

{{requestButtons}}

Catalog excerpts

BrightView X and XCT - 1

Fits you like no other BrightView X and XCT specifications The new BrightView X system is a fully featured variableangle camera that is field-upgradeable to BrightView XCT without any increase in room size or power requirements. Designed to put patients first, the system is easy to use, fast and reliable with exceptional image quality. BrightView X is differentiated by exclusive CloseUp high resolution technologies. Surprisingly compact given its capabilities, the heart of BrightView XCT is the unique integration of BrightView X with advanced Philips flat-panel X-ray technology. Substantial clinical advantages include co-planar SPECT and CT with no table index between acquisitions in many cases, flexible CT breathing protocols optimized for localization and attenuation correction, and high resolution at low CT dose levels. All of this is possible without changing the way you like to work or your patients’ comfort. Fully supported by the resources of Philips services, Philips offers you comprehensive support and training throughout the life of your system, giving you knowledge and experience to make the most of BrightView X and XCT from day one.

Open the catalog to page 1
BrightView X and XCT - 2

BrightView X and XCT specifications Camera characteristics JETStream acquisition Gantry dimensions Mobile acquisition console Weight (without collimators) 18˝ flat LCD monitor, keyboard and trackball or mouse Spectrum analyzers Power requirements Energy range Window adjustment 1% to entire energy range Spectrum display Color-coded, graphical, fully interactive Total heat dissipation (typical) BrightView X: 2850 BTU/hr BrightView XCT: 6831 BTU/hr Gantry aperture Caudal-cephalic tilt Count capacity Axial fields-of-view overlap by 14 cm Preset count or time Image orientation Patient position...

Open the catalog to page 2
BrightView X and XCT - 3

BrightView X and XCT detector specifications 3/4˝ (19.1 mm) crystal NEMA1 Intrinsic spatial resolution Integral Differential UFOV 4.3 mm 8.2 mm UFOV 9.8% UFOV 0.6 mm 0.2 mm UFOV ± 2.5% ± 2.0% FWHM without scatter FWTM without scatter FWHM with scatter FWTM with scatter Central transaxial Central axial Peripheral radial Peripheral tangential Peripheral axial FWHM FWTM Intrinsic energy resolution Intrinsic spatial linearity Intrinsic flood field uniformity3 System spatial resolution (LEHR) @ 10 cm SPECT reconstructed spatial resolution (LEHR) without scatter @ 15 cm radius Whole body system...

Open the catalog to page 3
BrightView X and XCT - 4

BrightView X and XCT detector specifications 3/8˝ (9.5 mm) crystal NEMA1 Intrinsic spatial resolution Integral Differential UFOV 3.3 mm 6.3 mm UFOV ≤ 9.6% UFOV 0.50 mm 0.10 mm UFOV ± 2.5% ± 2.0% FWHM without scatter FWTM without scatter FWHM with scatter FWTM with scatter Central transaxial Central axial Peripheral radial Peripheral tangential Peripheral axial FWHM FWTM 8.0 mm 14.7 mm 7.9 mm 14.5 mm UFOV 11500 (cts/sec) (MBq/cm2) UFOV 3.8 mm 7.3 mm Astonish** Astonish** 5.3 mm 9.7 mm 5.3 mm 9.7 mm UFOV 11500 (cts/sec) (MBq/cm2) UFOV 3.6 6.9 UFOV 300 Kcps 350 Kcps UFOV 277 cpm/μCi UFOV 0.4...

Open the catalog to page 4
BrightView X and XCT - 5

BrightView X and XCT system performance BrightView X and XCT camera and collimator specifications Septa Length (mm) (mm) Septa Sensitivity penetration Cpm/μCi (%) (keV) Hole shape Low energy general purpose Low energy high resolution Cardiac high resolution 1 Sensitivity is for Tc-99m with 20% window, 9.5 mm thick crystal. 2 Gallium-67 with 20% window 93 keV, 184 keV, 300 keV photo peaks. 3 Sensitivity is for I-131. 4 The pinhole collimator is rated for 364 keV and has 25.4 cm FOV at the crystal. 5 Relative sensitivity is for Tc-99m at 10 cm from the pinhole. 6 For 9.5 mm thick crystal....

Open the catalog to page 5
BrightView X and XCT - 6

BrightView XCT minimum room layout 186" (15'6") 4724 mm 176.52" 4484 mm Customer-provided desktop. Philips-provided computer, monitor and keyboard. Exam Room Pivot point Gantry Power generator Wall-mount acquisition terminal BrightView X has the same room requirements except the X-ray power generator is not included. Environmental requirements for general equipment location Throughout the SPECT suite, the HVAC system must maintain the temperature between 16°C (60°F) to 24°C (75°F) with less than 5°C (10°F) variation per hour. Humidity must be between 20% to 75%. These requirements are 24...

Open the catalog to page 6

All Philips Healthcare catalogs and technical brochures

  1. DreamMapper

    2 Pages

  2. DFM100

    6 Pages

  3. Trilogy 202

    4 Pages

  4. Sparq - DS

    4 Pages

  5. EPIQ 7

    20 Pages

  6. PerforMax

    2 Pages

  7. Philips TPI

    6 Pages

  8. BV Pulsera

    7 Pages

  9. Pinnacle3

    6 Pages

  10. HeartStart MRx

    12 Pages

  11. V60

    4 Pages

  12. MDE Brochure

    20 Pages

Archived catalogs